Filtered by vendor Schneider-electric
Subscribe
Search
Total
288 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-22713 | 1 Schneider-electric | 21 Ion7650 Firmware, Powerlogic Ion7300, Powerlogic Ion7300 Firmware and 18 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot. | |||||
| CVE-2021-22703 | 1 Schneider-electric | 20 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion7650 and 17 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device. | |||||
| CVE-2021-22702 | 1 Schneider-electric | 24 Powerlogic Ion7300, Powerlogic Ion7300 Firmware, Powerlogic Ion7400 and 21 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device. | |||||
| CVE-2021-22699 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP. | |||||
| CVE-2020-7566 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 4.3 MEDIUM | 7.3 HIGH |
| A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | |||||
| CVE-2020-7511 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to acquire a password by brute force. | |||||
| CVE-2020-7565 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 4.3 MEDIUM | 7.3 HIGH |
| A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | |||||
| CVE-2020-7510 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-200: Information Exposure vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow attacker to obtain private keys. | |||||
| CVE-2020-7488 | 1 Schneider-electric | 11 Ecostruxure Machine Expert, Modicon M218, Modicon M218 Firmware and 8 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. | |||||
| CVE-2019-6851 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol. | |||||
| CVE-2019-6845 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. | |||||
| CVE-2019-6859 | 1 Schneider-electric | 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network. | |||||
| CVE-2019-6857 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP. | |||||
| CVE-2019-6856 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP. | |||||
| CVE-2018-7789 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames. | |||||
| CVE-2018-7794 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP. | |||||
| CVE-2018-7792 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to decode the password using rainbow table. | |||||
| CVE-2019-6828 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus. | |||||
| CVE-2019-6820 | 1 Schneider-electric | 24 Atv Imc Drive Controller, Atv Imc Drive Controller Firmware, Modicon Lmc058 and 21 more | 2022-02-03 | 6.4 MEDIUM | 8.2 HIGH |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 | |||||
| CVE-2019-6813 | 1 Schneider-electric | 4 Bmxnor0200h, Bmxnor0200h Firmware, Modicon M340 and 1 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device. | |||||
| CVE-2019-6809 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller. | |||||
| CVE-2019-6807 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. | |||||
| CVE-2019-6806 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. | |||||
| CVE-2019-6829 | 1 Schneider-electric | 4 Modicon M340, Modicon M340 Firmware, Modicon M580 and 1 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus. | |||||
| CVE-2016-4529 | 1 Schneider-electric | 3 M171, M172, Somachine Hvac Firmware | 2022-02-03 | 7.5 HIGH | 7.3 HIGH |
| An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag. | |||||
| CVE-2020-7486 | 1 Schneider-electric | 12 Tricon Tcm 4351, Tricon Tcm 4351 Firmware, Tricon Tcm 4351a and 9 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| **VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior. | |||||
| CVE-2019-6826 | 1 Schneider-electric | 1 Somachine Hvac | 2022-02-03 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product. | |||||
| CVE-2018-7855 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus | |||||
| CVE-2018-7856 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus. | |||||
| CVE-2018-7857 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. | |||||
| CVE-2018-7852 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus. | |||||
| CVE-2018-7853 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus | |||||
| CVE-2018-7854 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. | |||||
| CVE-2018-7848 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus | |||||
| CVE-2018-7849 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus. | |||||
| CVE-2018-7844 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus. | |||||
| CVE-2018-7843 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus. | |||||
| CVE-2018-7845 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus. | |||||
| CVE-2020-7559 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. | |||||
| CVE-2021-22816 | 1 Schneider-electric | 18 Scadapack 312e, Scadapack 312e Firmware, Scadapack 313e and 15 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior | |||||
| CVE-2021-22808 | 1 Schneider-electric | 1 Guicon | 2022-02-02 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior | |||||
| CVE-2021-22807 | 1 Schneider-electric | 1 Guicon | 2022-02-02 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior | |||||
| CVE-2018-7230 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 6.8 MEDIUM | 8.8 HIGH |
| A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67. | |||||
| CVE-2018-7234 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate. | |||||
| CVE-2018-7235 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file' | |||||
| CVE-2018-7236 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2022-02-02 | 5.8 MEDIUM | 8.1 HIGH |
| A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service. | |||||
| CVE-2016-8374 | 1 Schneider-electric | 16 Magelis Gto Advanced Optimum Panel, Magelis Gto Advanced Optimum Panel Firmware, Magelis Gtu Universal Panel and 13 more | 2022-02-02 | 7.8 HIGH | 7.5 HIGH |
| An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION. | |||||
| CVE-2019-10953 | 5 Abb, Phoenixcontact, Schneider-electric and 2 more | 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. | |||||
| CVE-2018-7821 | 1 Schneider-electric | 3 Modicon M221, Modicon M221 Firmware, Somachine Basic | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated. | |||||
| CVE-2018-7798 | 1 Schneider-electric | 2 Modicon M221, Somachine Basic | 2022-01-31 | 6.4 MEDIUM | 8.2 HIGH |
| A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device. | |||||
