Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-7525 1 Schneider-electric 4 Spacelynk, Spacelynk Firmware, Wiser For Knx and 1 more 2020-09-04 5.0 MEDIUM 7.5 HIGH
Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used.
CVE-2020-7527 1 Schneider-electric 1 Somove 2020-09-04 4.6 MEDIUM 7.8 HIGH
Incorrect Default Permission vulnerability exists in SoMove (V2.8.1) and prior which could cause elevation of privilege and provide full access control to local system users to SoMove component and services when a SoMove installer script is launched.
CVE-2018-7831 1 Schneider-electric 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more 2020-08-24 4.3 MEDIUM 8.8 HIGH
An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on the web server.
CVE-2018-7779 1 Schneider-electric 6 Homelynk, Homelynk Firmware, Spacelynk and 3 more 2020-08-24 5.0 MEDIUM 7.5 HIGH
In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access.
CVE-2018-7793 1 Schneider-electric 4 Foxboro Dcs, Foxboro Evo, Foxview and 1 more 2020-08-24 4.6 MEDIUM 8.7 HIGH
A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission.
CVE-2018-7814 1 Schneider-electric 1 Guicon 2020-08-24 6.8 MEDIUM 7.8 HIGH
A Stack-based Buffer Overflow (CWE-121) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) which could cause remote code to be executed when parsing a GD1 file
CVE-2020-7514 1 Schneider-electric 1 Easergy Builder 2020-07-27 4.6 MEDIUM 7.8 HIGH
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker access to the authorization credentials for a device and gain full access.
CVE-2020-7518 1 Schneider-electric 1 Easergy Builder 2020-07-27 5.0 MEDIUM 7.5 HIGH
A CWE-20: Improper input validation vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to modify project configuration files.
CVE-2020-7519 1 Schneider-electric 1 Easergy Builder 2020-07-27 5.0 MEDIUM 7.5 HIGH
A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.
CVE-2012-0929 1 Schneider-electric 1 Modicon Quantum Plc 2020-07-23 7.8 HIGH 7.5 HIGH
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.
CVE-2020-7494 1 Schneider-electric 1 Ecostruxure Operator Terminal Expert 2020-06-19 6.8 MEDIUM 7.8 HIGH
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
CVE-2020-7509 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-17 6.5 MEDIUM 7.2 HIGH
A CWE-269: Improper privilege management (write) vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to elevate their privileges and delete files.
CVE-2020-7505 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-17 9.0 HIGH 7.2 HIGH
A CWE-494 Download of Code Without Integrity Check vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to inject data with dangerous content into the firmware and execute arbitrary code on the system.
CVE-2020-7493 1 Schneider-electric 1 Ecostruxure Operator Terminal Expert 2020-06-17 6.8 MEDIUM 7.8 HIGH
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
CVE-2020-7513 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-17 5.0 MEDIUM 7.5 HIGH
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to intercept traffic and read configuration data.
CVE-2020-7507 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-17 5.0 MEDIUM 7.5 HIGH
A CWE-400: Uncontrolled Resource Consumption vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to login multiple times resulting in a denial of service.
CVE-2020-7503 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2020-06-17 6.8 MEDIUM 8.8 HIGH
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to execute malicious commands on behalf of a legitimate user when xsrf-token data is intercepted.
CVE-2020-7478 1 Schneider-electric 1 Interactive Graphical Scada System 2020-04-03 5.0 MEDIUM 7.5 HIGH
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.
CVE-2020-7479 1 Schneider-electric 1 Interactive Graphical Scada System 2020-04-03 4.6 MEDIUM 7.8 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
CVE-2020-7476 1 Schneider-electric 1 Ulti Zigbee Installation Toolkit 2020-03-25 4.4 MEDIUM 7.8 HIGH
A CWE-426: Untrusted Search Path vulnerability exists in ZigBee Installation Kit (Versions prior to 1.0.1), which could cause execution of malicious code when a malicious file is put in the search path.
CVE-2020-7477 1 Schneider-electric 56 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 53 more 2020-03-25 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus.
CVE-2020-7474 1 Schneider-electric 1 Pmepxm0100 Prosoft Configurator 2020-03-25 4.4 MEDIUM 7.8 HIGH
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProSoft Configurator (v1.002 and prior), for the PMEPXM0100 (H) module, which could cause the execution of untrusted code when using double click to open a project file which may trigger execution of a malicious DLL.
CVE-2018-7777 1 Schneider-electric 1 U.motion Builder 2020-02-03 6.5 MEDIUM 8.8 HIGH
The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server.
CVE-2019-6858 1 Schneider-electric 1 Msx Configurator 2020-01-24 4.4 MEDIUM 7.8 HIGH
A CWE-427:Uncontrolled Search Path Element vulnerability exists in MSX Configurator (Software Version prior to V1.0.8.1), which could cause privilege escalation when injecting a malicious DLL.
CVE-2019-6852 1 Schneider-electric 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more 2019-11-22 5.0 MEDIUM 7.5 HIGH
A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.
CVE-2019-6849 1 Schneider-electric 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more 2019-11-01 5.0 MEDIUM 7.5 HIGH
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.
CVE-2019-6850 1 Schneider-electric 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more 2019-11-01 5.0 MEDIUM 7.5 HIGH
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.
CVE-2019-6825 1 Schneider-electric 1 Proclima 2019-10-09 6.8 MEDIUM 7.8 HIGH
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0.
CVE-2019-6811 1 Schneider-electric 4 Modicon Quantum 140noe77101, Modicon Quantum 140noe77101 Firmware, Modicon Quantum 140noe77111 and 1 more 2019-10-09 5.0 MEDIUM 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover.
CVE-2019-6832 1 Schneider-electric 4 Lss100100, Lss100200, Spacelynk Firmware and 1 more 2019-10-09 6.8 MEDIUM 8.3 HIGH
A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.
CVE-2018-8872 1 Schneider-electric 2 Triconex Tricon Mp 3008, Triconex Tricon Mp 3008 Firmware 2019-10-09 9.3 HIGH 8.1 HIGH
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
CVE-2018-7817 1 Schneider-electric 1 Zelio Soft 2 2019-10-09 6.8 MEDIUM 7.8 HIGH
A Use After Free (CWE-416) vulnerability exists in Zelio Soft 2 v5.1 and prior versions which could cause remote code execution when opening a specially crafted Zelio Soft project file.
CVE-2017-7968 1 Schneider-electric 1 Wonderware Indusoft Web Studio 2019-10-09 7.2 HIGH 7.8 HIGH
An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges.
CVE-2017-6033 1 Schneider-electric 1 Interactive Graphical Scada System 2019-10-09 6.8 MEDIUM 7.8 HIGH
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path.
CVE-2017-6021 2 Aveva, Schneider-electric 2 Clearscada, Clearscada 2019-10-09 5.0 MEDIUM 7.5 HIGH
In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
CVE-2015-1014 1 Schneider-electric 3 Citectscada, Opc Factory Server, Scada Expert Vijeo Citect 2019-10-09 4.4 MEDIUM 7.3 HIGH
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
CVE-2018-7781 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2019-10-03 4.0 MEDIUM 8.8 HIGH
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
CVE-2018-7782 1 Schneider-electric 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more 2019-10-03 4.0 MEDIUM 8.8 HIGH
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
CVE-2018-7240 1 Schneider-electric 26 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 23 more 2019-10-03 6.5 MEDIUM 8.8 HIGH
A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware.
CVE-2017-9967 1 Schneider-electric 1 Interactive Graphical Scada System 2019-10-03 4.6 MEDIUM 7.8 HIGH
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security.
CVE-2017-9966 1 Schneider-electric 1 Pelco Videoxpert 2019-10-03 7.1 HIGH 7.1 HIGH
A privilege escalation vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. By replacing certain files, an unauthorized user can obtain system privileges and the inserted code would execute at an elevated privilege level.
CVE-2017-9961 1 Schneider-electric 1 Pro-face Gp Pro Ex 2019-10-03 4.6 MEDIUM 7.8 HIGH
A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.
CVE-2017-9958 1 Schneider-electric 1 U.motion Builder 2019-10-03 7.2 HIGH 7.8 HIGH
An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an improper handling of the system configuration can allow an attacker to execute arbitrary code under the context of root.
CVE-2017-7966 1 Schneider-electric 1 Somachine 2019-10-03 6.8 MEDIUM 8.8 HIGH
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.
CVE-2017-5155 1 Schneider-electric 1 Wonderware Historian 2019-10-03 7.5 HIGH 7.3 HIGH
An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.
CVE-2019-6831 1 Schneider-electric 2 Bmxnor0200h, Bmxnor0200h Firmware 2019-10-02 5.0 MEDIUM 8.6 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP.
CVE-2019-6810 1 Schneider-electric 2 Bmxnor0200h, Bmxnor0200h Firmware 2019-10-02 6.5 MEDIUM 8.8 HIGH
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.
CVE-2019-6812 1 Schneider-electric 2 Bmx-nor-0200h, Bmx-nor-0200h Firmware 2019-09-30 4.0 MEDIUM 7.2 HIGH
A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol.
CVE-2019-6822 1 Schneider-electric 1 Zelio Soft 2 2019-07-22 6.8 MEDIUM 7.8 HIGH
A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.
CVE-2019-6827 1 Schneider-electric 1 Interactive Graphical Scada System 2019-07-22 6.8 MEDIUM 7.8 HIGH
A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.