Filtered by vendor Schneider-electric
Subscribe
Search
Total
288 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-22766 | 1 Schneider-electric | 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| ** UNSUPPORTED WHEN ASSIGNED ** A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet. | |||||
| CVE-2020-7502 | 1 Schneider-electric | 2 Modicon M218, Modicon M218 Firmware | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (Firmware version 4.3 and prior), which may cause a Denial of Service when specific TCP/IP crafted packets are sent to the Modicon M218 Logic Controller. | |||||
| CVE-2020-7524 | 1 Schneider-electric | 2 Modicon M218, Modicon M218 Firmware | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal. | |||||
| CVE-2020-7569 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution. | |||||
| CVE-2020-7572 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser. | |||||
| CVE-2020-7501 | 1 Schneider-electric | 1 Vijeo Designer | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer. | |||||
| CVE-2017-7965 | 1 Schneider-electric | 1 Somachine Hvac | 2022-01-31 | 4.6 MEDIUM | 7.3 HIGH |
| A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller. | |||||
| CVE-2018-7783 | 1 Schneider-electric | 1 Somachine Basic | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is triggered when input passed to the xml parser is not sanitized while parsing the xml project/template file. | |||||
| CVE-2020-7490 | 1 Schneider-electric | 1 Vijeo Designer | 2022-01-31 | 6.9 MEDIUM | 7.8 HIGH |
| A CWE-426: Untrusted Search Path vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 15 and prior) and Vijeo Designer (V6.9 SP9 and prior), which could cause arbitrary code execution on the system running Vijeo Basic when a malicious DLL library is loaded by the Product. | |||||
| CVE-2021-22777 | 1 Schneider-electric | 1 Sosafe Configurable | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file. | |||||
| CVE-2016-2290 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 6.8 MEDIUM | 8.8 HIGH |
| Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. | |||||
| CVE-2021-22697 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |||||
| CVE-2020-7544 | 1 Schneider-electric | 1 Operator Terminal Expert Runtime | 2022-01-31 | 7.2 HIGH | 7.8 HIGH |
| A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert. | |||||
| CVE-2019-6855 | 1 Schneider-electric | 44 Ecostruxure Control Expert, Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware and 41 more | 2022-01-31 | 7.5 HIGH | 7.3 HIGH |
| Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. | |||||
| CVE-2020-28213 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus. | |||||
| CVE-2020-10626 | 2 Fazecast, Schneider-electric | 2 Jserialcomm, Ecostruxure It Gateway | 2022-01-31 | 6.9 MEDIUM | 7.8 HIGH |
| In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. | |||||
| CVE-2020-7538 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. | |||||
| CVE-2020-7560 | 1 Schneider-electric | 2 Ecostruxure Control Expert, Unity Pro | 2022-01-31 | 6.8 MEDIUM | 8.6 HIGH |
| A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. | |||||
| CVE-2020-28209 | 2 Microsoft, Schneider-electric | 2 Windows, Enterprise Server Installer | 2022-01-31 | 4.4 MEDIUM | 7.0 HIGH |
| A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administrator privileges so the vulnerability is only valid if the application has been installed on a non-secure location. | |||||
| CVE-2021-22698 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |||||
| CVE-2021-22705 | 1 Schneider-electric | 9 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 6 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert | |||||
| CVE-2020-28211 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger. | |||||
| CVE-2020-7552 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2022-01-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7551 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2022-01-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7515 | 1 Schneider-electric | 1 Easergy Builder | 2021-12-10 | 2.1 LOW | 7.8 HIGH |
| A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password. | |||||
| CVE-2020-7516 | 1 Schneider-electric | 1 Easergy Builder | 2021-12-10 | 2.1 LOW | 7.8 HIGH |
| A CWE-316: Cleartext Storage of Sensitive Information in Memory vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker access to login credentials. | |||||
| CVE-2021-22720 | 1 Schneider-electric | 1 C-bus Toolkit | 2021-11-30 | 6.5 MEDIUM | 7.2 HIGH |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project. | |||||
| CVE-2020-7484 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2021-11-10 | 4.3 MEDIUM | 7.5 HIGH |
| **VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former 'password' feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions. | |||||
| CVE-2020-7483 | 2 Microsoft, Schneider-electric | 4 Windows 7, Windows Nt, Windows Xp and 1 more | 2021-11-08 | 5.0 MEDIUM | 7.5 HIGH |
| **VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause certain data to be visible on the network when the 'password' feature is enabled. This vulnerability was discovered in and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. The 'password' feature is an additional optional check performed by TS1131 that it is connected to a specific controller. This data is sent as clear text and is visible on the network. This feature is not present in TriStation 1131 versions v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions. | |||||
| CVE-2019-6854 | 1 Schneider-electric | 1 Clearscada | 2021-11-03 | 4.6 MEDIUM | 7.8 HIGH |
| A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017. | |||||
| CVE-2019-6839 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2021-09-14 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file. | |||||
| CVE-2021-22793 | 1 Schneider-electric | 5 Accusine Pcs\+, Accusine Pcsn, Accusine Pcsn Active Harmonic Filter Firmware and 2 more | 2021-09-13 | 6.5 MEDIUM | 7.2 HIGH |
| A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol. | |||||
| CVE-2021-22792 | 1 Schneider-electric | 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more | 2021-09-13 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). | |||||
| CVE-2021-22775 | 1 Schneider-electric | 1 Gp-pro Ex | 2021-09-10 | 4.4 MEDIUM | 7.8 HIGH |
| A CWE-427: Uncontrolled Search Path Element vulnerability exists in GP-Pro EX,V4.09.250 and prior, that could cause local code execution with elevated privileges when installing the software. | |||||
| CVE-2020-7537 | 1 Schneider-electric | 38 Bmxp341000, Bmxp341000 Firmware, Bmxp342000 and 35 more | 2021-08-18 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. | |||||
| CVE-2018-7838 | 1 Schneider-electric | 36 Bmeh582040, Bmeh582040 Firmware, Bmeh582040c and 33 more | 2021-08-18 | 7.8 HIGH | 7.5 HIGH |
| A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service. | |||||
| CVE-2020-7543 | 1 Schneider-electric | 32 Bmxp341000, Bmxp341000 Firmware, Bmxp342000 and 29 more | 2021-08-18 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. | |||||
| CVE-2019-6819 | 1 Schneider-electric | 38 Bmeh582040, Bmeh582040c, Bmeh584040 and 35 more | 2021-08-18 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium. | |||||
| CVE-2020-7542 | 1 Schneider-electric | 40 140cpu65150, 140cpu65150 Firmware, Bmxp341000 and 37 more | 2021-08-18 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. | |||||
| CVE-2021-22726 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 5.5 MEDIUM | 8.1 HIGH |
| A CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to perform unintended actions or access to data when crafted malicious parameters are submitted to the charging station web server. | |||||
| CVE-2021-22708 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 6.5 MEDIUM | 7.2 HIGH |
| A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to craft a malicious firmware package and bypass the signature verification mechanism. | |||||
| CVE-2021-22771 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2021-07-28 | 6.0 MEDIUM | 7.3 HIGH |
| A CWE-1236: Improper Neutralization of Formula Elements in a CSV File vulnerability exists in Easergy T300 with firmware V2.7.1 and older that would allow arbitrary command execution. | |||||
| CVE-2021-22774 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2021-07-28 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get knowledge of charging station user account credentials using dictionary attacks techniques. | |||||
| CVE-2021-22780 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2021-07-26 | 3.6 LOW | 7.1 HIGH |
| Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file. | |||||
| CVE-2021-22778 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2021-07-26 | 3.6 LOW | 7.1 HIGH |
| Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. | |||||
| CVE-2021-22761 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22762 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition. | |||||
| CVE-2021-22760 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22759 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22753 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition. | |||||
