| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-22754 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22758 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22750 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22751 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2021-22752 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition. | |||||
| CVE-2021-22757 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22756 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2021-22755 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-06-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition. | |||||
| CVE-2020-7506 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2021-06-11 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-200: Information Exposure vulnerability exists in Easergy T300, Firmware V1.5.2 and prior, which could allow an attacker to pack or unpack the archive with the firmware for the controller and modules using the usual tar archiver resulting in an information exposure. | |||||
| CVE-2017-9627 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2021-06-07 | 5.0 MEDIUM | 8.6 HIGH |
| An Uncontrolled Resource Consumption issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The uncontrolled resource consumption vulnerability could allow an attacker to exhaust the memory resources of the machine, causing a denial of service. | |||||
| CVE-2021-22736 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2021-06-04 | 5.0 MEDIUM | 7.5 HIGH |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a denial of service when an unauthorized file is uploaded. | |||||
| CVE-2021-22735 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2021-06-04 | 6.5 MEDIUM | 7.2 HIGH |
| Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device. | |||||
| CVE-2021-22734 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2021-06-04 | 6.5 MEDIUM | 7.2 HIGH |
| Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause remote code execution when an attacker loads unauthorized code. | |||||
| CVE-2020-7523 | 1 Schneider-electric | 2 Modbus Driver Suite, Modbus Serial Driver | 2021-06-04 | 4.4 MEDIUM | 7.8 HIGH |
| Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor. | |||||
| CVE-2021-22733 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2021-06-04 | 4.6 MEDIUM | 7.8 HIGH |
| Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder. | |||||
| CVE-2021-22732 | 1 Schneider-electric | 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more | 2021-06-04 | 4.6 MEDIUM | 7.8 HIGH |
| Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a code execution issue when an attacker loads unauthorized code on the web server. | |||||
| CVE-2021-22716 | 1 Schneider-electric | 1 C-bus Toolkit | 2021-06-02 | 4.6 MEDIUM | 7.8 HIGH |
| A CWE-269: Improper Privilege Management vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when an unprivileged user modifies a file. | |||||
| CVE-2021-22717 | 1 Schneider-electric | 1 C-bus Toolkit | 2021-06-02 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files. | |||||
| CVE-2021-22718 | 1 Schneider-electric | 1 C-bus Toolkit | 2021-06-02 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files. | |||||
| CVE-2021-22719 | 1 Schneider-electric | 1 C-bus Toolkit | 2021-06-02 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded. | |||||
| CVE-2019-6848 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2021-04-19 | 5.0 MEDIUM | 8.6 HIGH |
| A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module. | |||||
| CVE-2019-6836 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2021-04-16 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file. | |||||
| CVE-2021-22710 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-18 | 9.3 HIGH | 7.8 HIGH |
| A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2021-22711 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-17 | 9.3 HIGH | 7.8 HIGH |
| A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data. | |||||
| CVE-2021-22709 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-17 | 9.3 HIGH | 7.8 HIGH |
| A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2021-22712 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-17 | 9.3 HIGH | 7.8 HIGH |
| A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address. | |||||
| CVE-2020-7553 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-03-15 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7550 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7554 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7556 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7557 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7558 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-02-01 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-7555 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2021-01-30 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | |||||
| CVE-2020-28219 | 1 Schneider-electric | 2 Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 | 2020-12-16 | 2.1 LOW | 7.8 HIGH |
| A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX. | |||||
| CVE-2020-7539 | 1 Schneider-electric | 40 140cpu65150, 140cpu65150 Firmware, 140noc77101 and 37 more | 2020-12-14 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a specially crafted packet is sent to the controller over HTTP. | |||||
| CVE-2020-7536 | 1 Schneider-electric | 20 Bmxnoe0100, Bmxnoe0100 Firmware, Bmxnoe0110 and 17 more | 2020-12-14 | 7.8 HIGH | 7.5 HIGH |
| A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP. | |||||
| CVE-2020-7535 | 1 Schneider-electric | 42 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 39 more | 2020-12-14 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of information when sending a specially crafted request to the controller over HTTP. | |||||
| CVE-2020-28217 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. | |||||
| CVE-2020-28216 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-12-14 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. | |||||
| CVE-2020-7547 | 1 Schneider-electric | 5 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Power Manager and 2 more | 2020-12-04 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level. | |||||
| CVE-2020-7545 | 1 Schneider-electric | 5 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Power Manager and 2 more | 2020-12-04 | 6.5 MEDIUM | 7.2 HIGH |
| A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage. | |||||
| CVE-2020-7562 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2020-12-02 | 5.8 MEDIUM | 8.1 HIGH |
| A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP. | |||||
| CVE-2020-7563 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2020-12-02 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP. | |||||
| CVE-2020-7564 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2020-12-02 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP. | |||||
| CVE-2019-10981 | 1 Schneider-electric | 2 Citectscada, Scada Expert Vijeo Citect | 2020-10-02 | 2.1 LOW | 7.8 HIGH |
| In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. | |||||
| CVE-2020-7528 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which could allow arbitrary code execution when an attacker builds a custom .PRJ file containing a malicious serialized buffer. | |||||
| CVE-2020-7530 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders. | |||||
| CVE-2020-7531 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user. | |||||
| CVE-2020-7532 | 1 Schneider-electric | 1 Scadapack X70 Security Administrator | 2020-09-21 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack x70 Security Administrator (V1.2.0 and prior) which could allow arbitrary code execution when an attacker builds a custom .SDB file containing a malicious serialized buffer. | |||||
| CVE-2018-1124 | 6 Canonical, Debian, Opensuse and 3 more | 9 Ubuntu Linux, Debian Linux, Leap and 6 more | 2020-09-09 | 4.6 MEDIUM | 7.8 HIGH |
| procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users. | |||||