| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-0425 | 1 Abb | 6 Ac700f, Ac700f Firmware, Ac900f and 3 more | 2023-08-14 | N/A | 7.5 HIGH |
| ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Numeric Range Comparison Without Minimum Check vulnerability in ABB Freelance controllers AC 700F (Controller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1. | |||||
| CVE-2023-0426 | 1 Abb | 6 Ac700f, Ac700f Firmware, Ac900f and 3 more | 2023-08-14 | N/A | 7.5 HIGH |
| ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Stack-based Buffer Overflow vulnerability in ABB Freelance controllers AC 700F (conroller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019 , through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1. | |||||
| CVE-2023-2685 | 1 Abb | 1 Ao-opc | 2023-08-04 | N/A | 6.3 MEDIUM |
| A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service might be started with system user privileges which could cause a shift in user access privileges. It is unlikely to exploit the vulnerability in well maintained Windows installations since the attacker would need write access to system folders. An update is available that resolves the vulnerability found during an internal review in the product AO-OPC = 3.2.1 | |||||
| CVE-2023-1258 | 1 Abb | 16 Flow-x\/c, Flow-x\/c Firmware, Flow-x\/k and 13 more | 2023-08-02 | N/A | 5.3 MEDIUM |
| Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0. | |||||
| CVE-2023-3321 | 1 Abb | 1 Zenon | 2023-08-02 | N/A | 8.8 HIGH |
| A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | |||||
| CVE-2023-3324 | 1 Abb | 1 Zenon | 2023-08-01 | N/A | 7.5 HIGH |
| A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | |||||
| CVE-2023-3323 | 1 Abb | 1 Zenon | 2023-08-01 | N/A | 5.4 MEDIUM |
| A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | |||||
| CVE-2023-3322 | 1 Abb | 1 Zenon | 2023-08-01 | N/A | 8.1 HIGH |
| A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | |||||
| CVE-2022-0902 | 1 Abb | 14 Rmc-100, Rmc-100-lite, Rmc-100-lite Firmware and 11 more | 2022-07-28 | N/A | 9.8 CRITICAL |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node. | |||||
| CVE-2020-24672 | 1 Abb | 1 Base Software | 2022-07-08 | 6.8 MEDIUM | 9.8 CRITICAL |
| A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: . | |||||
| CVE-2022-1596 | 1 Abb | 6 Rex640 Pcl1, Rex640 Pcl1 Firmware, Rex640 Pcl2 and 3 more | 2022-06-29 | 4.0 MEDIUM | 6.5 MEDIUM |
| Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node. | |||||
| CVE-2022-31219 | 1 Abb | 3 Automation Builder, Drive Composer, Mint Workbench | 2022-06-24 | 7.2 HIGH | 7.8 HIGH |
| Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product. | |||||
| CVE-2022-31218 | 1 Abb | 3 Automation Builder, Drive Composer, Mint Workbench | 2022-06-24 | 7.2 HIGH | 7.8 HIGH |
| Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product. | |||||
| CVE-2022-31217 | 1 Abb | 3 Automation Builder, Drive Composer, Mint Workbench | 2022-06-24 | 7.2 HIGH | 7.8 HIGH |
| Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product. | |||||
| CVE-2022-26057 | 1 Abb | 1 Mint Workbench | 2022-06-24 | 7.2 HIGH | 7.8 HIGH |
| Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product | |||||
| CVE-2022-31216 | 1 Abb | 3 Automation Builder, Drive Composer, Mint Workbench | 2022-06-24 | 7.2 HIGH | 7.8 HIGH |
| Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product. | |||||
| CVE-2021-35532 | 1 Abb | 2 Txpert Hub Coretec 4, Txpert Hub Coretec 4 Firmware | 2022-06-16 | 7.2 HIGH | 6.7 MEDIUM |
| A vulnerability exists in the file upload validation part of Hitachi Energy TXpert Hub CoreTec 4 product. The vulnerability allows an attacker or malicious agent who manages to gain access to the system and obtain an account with sufficient privilege to upload a malicious firmware to the product. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0; 2.0.1; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1. | |||||
| CVE-2021-35531 | 1 Abb | 2 Txpert Hub Coretec 4, Txpert Hub Coretec 4 Firmware | 2022-06-16 | 7.2 HIGH | 6.7 MEDIUM |
| Improper Input Validation vulnerability in a particular configuration setting field of Hitachi Energy TXpert Hub CoreTec 4 product, allows an attacker with access to an authorized user with ADMIN or ENGINEER role rights to inject an OS command that is executed by the system. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0; 2.0.1; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1. | |||||
| CVE-2021-35530 | 1 Abb | 2 Txpert Hub Coretec 4, Txpert Hub Coretec 4 Firmware | 2022-06-16 | 7.2 HIGH | 8.2 HIGH |
| A vulnerability in the application authentication and authorization mechanism in Hitachi Energy's TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling an unauthorized actor to change an existing user password, and further gain authorized access into the system via login mechanism. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0 2.1.0; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1. | |||||
| CVE-2022-0947 | 1 Abb | 48 Arc600a2323na, Arc600a2323na Firmware, Arc600a2324na and 45 more | 2022-05-18 | 6.8 MEDIUM | 9.8 CRITICAL |
| A vulnerability in ABB ARG600 Wireless Gateway series that could allow an attacker to exploit the vulnerability by remotely connecting to the serial port gateway, and/or protocol converter, depending on the configuration. | |||||
| CVE-2022-28613 | 1 Abb | 2 Rtu500, Rtu500 Firmware | 2022-05-12 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy RTU500 series CMU Firmware 12.0.*; 12.2.*; 12.4.*; 12.6.*; 12.7.*; 13.2.*. | |||||
| CVE-2021-22285 | 1 Abb | 4 Pni800, Pni800 Firmware, Spiet800 and 1 more | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
| Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive. | |||||
| CVE-2021-22286 | 1 Abb | 4 Pni800, Pni800 Firmware, Spiet800 and 1 more | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
| Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive. | |||||
| CVE-2021-22288 | 1 Abb | 4 Pni800, Pni800 Firmware, Spiet800 and 1 more | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
| Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive. | |||||
| CVE-2021-22284 | 1 Abb | 1 Opc Server For Ac 800m | 2022-02-09 | 6.5 MEDIUM | 8.8 HIGH |
| Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server. | |||||
| CVE-2019-10953 | 5 Abb, Phoenixcontact, Schneider-electric and 2 more | 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. | |||||
| CVE-2019-7229 | 1 Abb | 15 Board Support Package Un31, Cp620, Cp620-web and 12 more | 2022-01-01 | 5.4 MEDIUM | 8.3 HIGH |
| The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: "Utilization of USB/SD Card to flash the device" and "Remote provisioning process via ABB Panel Builder 600 over FTP." Neither of these transmission methods implements any form of encryption or authenticity checks against the new firmware HMI software binary files. | |||||
| CVE-2019-18998 | 1 Abb | 1 Asset Suite | 2022-01-01 | 5.5 MEDIUM | 7.1 HIGH |
| Insufficient access control in the web interface of ABB Asset Suite versions 9.0 to 9.3, 9.4 prior to 9.4.2.6, 9.5 prior to 9.5.3.2 and 9.6.0 enables full access to directly referenced objects. An attacker with knowledge of a resource's URL can access the resource directly. | |||||
| CVE-2021-22279 | 1 Abb | 2 Omnicore C30, Omnicore C30 Firmware | 2021-12-17 | 9.3 HIGH | 9.8 CRITICAL |
| A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port. | |||||
| CVE-2021-35533 | 1 Abb | 2 Rtu500, Rtu500 Firmware | 2021-11-30 | 7.1 HIGH | 7.5 HIGH |
| Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions). | |||||
| CVE-2019-19107 | 2 Abb, Busch-jaeger | 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more | 2021-11-03 | 2.1 LOW | 5.5 MEDIUM |
| The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed). | |||||
| CVE-2019-19104 | 2 Abb, Busch-jaeger | 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more | 2021-11-03 | 7.5 HIGH | 9.8 CRITICAL |
| The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation. | |||||
| CVE-2021-22278 | 1 Abb | 2 Pcm600, Update Manager | 2021-11-03 | 4.6 MEDIUM | 6.7 MEDIUM |
| A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed. | |||||
| CVE-2019-18250 | 1 Abb | 2 Plant Connect, Power Generation Information Manager | 2021-10-29 | 7.5 HIGH | 9.8 CRITICAL |
| In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device. | |||||
| CVE-2021-22272 | 2 Abb, Busch-jaeger | 2 Mybuildings, Mybusch-jaeger | 2021-10-08 | 9.0 HIGH | 9.4 CRITICAL |
| The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch | |||||
| CVE-2020-24678 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 6.5 MEDIUM | 8.8 HIGH |
| An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges. | |||||
| CVE-2020-24677 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 6.5 MEDIUM | 8.8 HIGH |
| Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirect the user somewhere else or download unwanted data. | |||||
| CVE-2020-24675 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 7.5 HIGH | 9.8 CRITICAL |
| In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process. | |||||
| CVE-2020-24680 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 4.6 MEDIUM | 7.0 HIGH |
| In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database. | |||||
| CVE-2020-24683 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 7.5 HIGH | 9.8 CRITICAL |
| The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application. | |||||
| CVE-2020-24679 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 10.0 HIGH | 9.8 CRITICAL |
| A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted. | |||||
| CVE-2020-24674 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 9.0 HIGH | 8.8 HIGH |
| In S+ Operations and S+ Historian, not all client commands correctly check user permission as expected. Authenticated but Unauthorized remote users could execute a Denial-of-Service (DoS) attack, execute arbitrary code, or obtain more privilege than intended on the machines. | |||||
| CVE-2020-24673 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-10-07 | 7.5 HIGH | 9.8 CRITICAL |
| In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability. | |||||
| CVE-2021-22276 | 1 Abb | 10 System Access Point 127v, System Access Point 127v Firmware, System Access Point 2.0 and 7 more | 2021-10-06 | 4.3 MEDIUM | 5.5 MEDIUM |
| The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point. | |||||
| CVE-2021-35527 | 1 Abb | 1 Esoms | 2021-09-16 | 5.0 MEDIUM | 7.5 HIGH |
| Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. This issue affects: Hitachi ABB Power Grids eSOMS version 6.3 and prior versions. | |||||
| CVE-2020-24676 | 1 Abb | 2 Symphony \+ Historian, Symphony \+ Operations | 2021-09-14 | 4.6 MEDIUM | 7.8 HIGH |
| In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as. | |||||
| CVE-2020-8481 | 1 Abb | 1 800xa System | 2021-09-14 | 10.0 HIGH | 9.8 CRITICAL |
| For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer. | |||||
| CVE-2020-11420 | 2 Abb, Generex | 4 Cs141, Cs141 Firmware, Cs141 and 1 more | 2021-09-14 | 4.0 MEDIUM | 6.5 MEDIUM |
| UPS Adapter CS141 before 1.90 allows Directory Traversal. An attacker with Admin or Engineer login credentials could exploit the vulnerability by manipulating variables that reference files and by doing this achieve access to files and directories outside the web root folder. An attacker may access arbitrary files and directories stored in the file system, but integrity of the files are not jeopardized as attacker have read access rights only. | |||||
| CVE-2019-19106 | 2 Abb, Busch-jaeger | 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more | 2021-09-14 | 6.4 MEDIUM | 9.1 CRITICAL |
| Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings. | |||||
| CVE-2021-27196 | 1 Abb | 18 Fox615 Tego1, Fox615 Tego1 Firmware, Gms600 and 15 more | 2021-07-08 | 5.0 MEDIUM | 7.5 HIGH |
| Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1. | |||||