Filtered by vendor Siemens
Subscribe
Search
Total
1276 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-0847 | 7 Fedoraproject, Linux, Netapp and 4 more | 39 Fedora, Linux Kernel, H300e and 36 more | 2024-01-12 | 7.2 HIGH | 7.8 HIGH |
| A flaw was found in the way the "flags" member of the new pipe buffer structure was lacking proper initialization in copy_page_to_iter_pipe and push_pipe functions in the Linux kernel and could thus contain stale values. An unprivileged local user could use this flaw to write to pages in the page cache backed by read only files and as such escalate their privileges on the system. | |||||
| CVE-2023-49251 | 1 Siemens | 1 Simatic Cn 4100 | 2024-01-12 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up. | |||||
| CVE-2023-49621 | 1 Siemens | 1 Simatic Cn 4100 | 2024-01-11 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device. | |||||
| CVE-2023-49252 | 1 Siemens | 1 Simatic Cn 4100 | 2024-01-11 | N/A | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The affected application allows IP configuration change without authentication to the device. This could allow an attacker to cause denial of service condition. | |||||
| CVE-2023-51744 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-01-11 | N/A | 5.5 MEDIUM |
| A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | |||||
| CVE-2023-51745 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-01-11 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-51439 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-01-11 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-51746 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2024-01-11 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-23588 | 2 Microchip, Siemens | 10 Maxview Storage Manager, Simatic Ipc1047, Simatic Ipc1047 Firmware and 7 more | 2024-01-11 | N/A | 6.3 MEDIUM |
| A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit. | |||||
| CVE-2002-20001 | 6 Balasys, F5, Hpe and 3 more | 49 Dheater, Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager and 46 more | 2024-01-11 | 5.0 MEDIUM | 7.5 HIGH |
| The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)at or D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE. | |||||
| CVE-2023-49123 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-49122 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-49121 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-49129 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-49132 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
| CVE-2023-49131 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
| CVE-2023-49130 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
| CVE-2023-49124 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-49126 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-49128 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-49127 | 1 Siemens | 1 Solid Edge Se2023 | 2024-01-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2019-13947 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 4.0 MEDIUM | 4.9 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The user configuration menu in the web interface of the Control Center Server (CCS) transfers user passwords in clear to the client (browser). An attacker with administrative privileges for the web interface could be able to read (and not only reset) passwords of other CCS users. | |||||
| CVE-2019-18340 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 2.1 LOW | 5.5 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), Control Center Server (CCS) (All versions >= V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store user and device passwords by applying weak cryptography. A local attacker could exploit this vulnerability to extract the passwords from the user database and/or the device configuration files to conduct further attacks. | |||||
| CVE-2019-19291 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 3.5 LOW | 5.3 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0). The FTP services of the SiVMS/SiNVR Video Server and the Control Center Server (CCS) maintain log files that store login credentials in cleartext. In configurations where the FTP service is enabled, authenticated remote attackers could extract login credentials of other users of the service. | |||||
| CVE-2019-19290 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 4.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The DOWNLOADS section in the web interface of the Control Center Server (CCS) contains a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server where CCS is installed. | |||||
| CVE-2019-18342 | 1 Siemens | 1 Control Center Server | 2024-01-09 | 7.5 HIGH | 9.9 CRITICAL |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) does not properly limit its capabilities to the specified purpose. In conjunction with CVE-2019-18341, an unauthenticated remote attacker with network access to the CCS server could exploit this vulnerability to read or delete arbitrary files, or access other resources on the same server. | |||||
| CVE-2019-18337 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext. | |||||
| CVE-2023-46283 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2024-01-09 | N/A | 7.5 HIGH |
| A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions < V4.1), SINUMERIK Integrate RunMyHMI /Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. | |||||
| CVE-2023-46281 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2024-01-09 | N/A | 8.8 HIGH |
| A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions < V4.1), SINUMERIK Integrate RunMyHMI /Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior. | |||||
| CVE-2019-19299 | 1 Siemens | 1 Sinvr\/sivms Video Server | 2024-01-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2), SiNVR/SiVMS Video Server (All versions >= V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server applies weak cryptography when exposing device (camera) passwords. This could allow an unauthenticated remote attacker to read and decrypt the passwords and conduct further attacks. | |||||
| CVE-2023-30901 | 1 Siemens | 2 Q200, Q200 Firmware | 2024-01-09 | N/A | 8.8 HIGH |
| A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user. | |||||
| CVE-2019-19298 | 1 Siemens | 1 Sinvr\/sivms Video Server | 2024-01-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server contains a input validation vulnerability, that could allow an unauthenticated remote attacker to cause a Denial-of-Service condition by sending malformed HTTP requests. | |||||
| CVE-2023-46285 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2024-01-09 | N/A | 7.5 HIGH |
| A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions < V4.1), SINUMERIK Integrate RunMyHMI /Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. | |||||
| CVE-2019-18339 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. A remote attacker with network access to the Video Server could exploit this vulnerability to read the SiVMS/SiNVR users database, including the passwords of all users in obfuscated cleartext. | |||||
| CVE-2022-43546 | 1 Siemens | 4 7kg9501-0aa01-2aa1, 7kg9501-0aa01-2aa1 Firmware, 7kg9501-0aa31-2aa1 and 1 more | 2024-01-09 | N/A | 8.8 HIGH |
| A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the EndTime-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device. | |||||
| CVE-2023-31238 | 1 Siemens | 2 Q200, Q200 Firmware | 2024-01-09 | N/A | 4.8 MEDIUM |
| A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. | |||||
| CVE-2023-46284 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2024-01-09 | N/A | 7.5 HIGH |
| A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions < V4.1), SINUMERIK Integrate RunMyHMI /Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. | |||||
| CVE-2022-43545 | 1 Siemens | 4 7kg9501-0aa01-2aa1, 7kg9501-0aa01-2aa1 Firmware, 7kg9501-0aa31-2aa1 and 1 more | 2024-01-09 | N/A | 8.8 HIGH |
| A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the RecordType-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device. | |||||
| CVE-2019-19292 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands. | |||||
| CVE-2019-19295 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 4.0 MEDIUM | 4.3 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to perform covert actions that are not visible in the application log. | |||||
| CVE-2019-19296 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 4.9 MEDIUM | 6.8 MEDIUM |
| A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The two FTP services (default ports 21/tcp and 5411/tcp) of the SiVMS/SiNVR Video Server contain a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server, if the FTP services are enabled. | |||||
| CVE-2019-19294 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 3.5 LOW | 6.3 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains multiple stored Cross-site Scripting (XSS) vulnerabilities in several input fields. This could allow an authenticated remote attacker to inject malicious JavaScript code into the CCS web application that is later executed in the browser context of any other user who views the relevant CCS web content. | |||||
| CVE-2019-18341 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations). | |||||
| CVE-2019-18338 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 4.0 MEDIUM | 7.7 HIGH |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains a directory traversal vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker with network access to the CCS server could exploit this vulnerability to list arbitrary directories or read files outside of the CCS application context. | |||||
| CVE-2022-43439 | 1 Siemens | 4 7kg9501-0aa01-2aa1, 7kg9501-0aa01-2aa1 Firmware, 7kg9501-0aa31-2aa1 and 1 more | 2024-01-09 | N/A | 8.8 HIGH |
| A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device. | |||||
| CVE-2022-43398 | 1 Siemens | 4 7kg9501-0aa01-2aa1, 7kg9501-0aa01-2aa1 Firmware, 7kg9501-0aa31-2aa1 and 1 more | 2024-01-09 | N/A | 8.8 HIGH |
| A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session. | |||||
| CVE-2019-19297 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server contains a path traversal vulnerability, that could allow an unauthenticated remote attacker to access and download arbitrary files from the server. | |||||
| CVE-2019-19293 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 4.3 MEDIUM | 6.1 MEDIUM |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains a reflected Cross-site Scripting (XSS) vulnerability that could allow an unauthenticated remote attacker to steal sensitive data or execute administrative actions on behalf of a legitimate administrator of the CCS web interface. | |||||
| CVE-2023-46282 | 1 Siemens | 4 Opcenter Quality, Simatic Pcs Neo, Sinumerik Integrate Runmyhmi \/automotive and 1 more | 2024-01-09 | N/A | 6.1 MEDIUM |
| A vulnerability has been identified in Opcenter Quality (All versions), SIMATIC PCS neo (All versions < V4.1), SINUMERIK Integrate RunMyHMI /Automotive (All versions), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. | |||||
| CVE-2021-22930 | 4 Debian, Netapp, Nodejs and 1 more | 4 Debian Linux, Nextgen Api, Node.js and 1 more | 2024-01-05 | 7.5 HIGH | 9.8 CRITICAL |
| Node.js before 16.6.0, 14.17.4, and 12.22.4 is vulnerable to a use after free attack where an attacker might be able to exploit the memory corruption, to change process behavior. | |||||