Search
Total
49350 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-6756 | 1 Cisco | 1 Prime Collaboration Provisioning | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| A vulnerability in the Web UI Application of the Cisco Prime Collaboration Provisioning Tool through 12.2 could allow an unauthenticated, remote attacker to execute unwanted actions. The vulnerability is due to a lack of defense against cross-site request forgery (CSRF) attacks. An attacker could exploit this vulnerability by forcing the user's browser to perform any action authorized for that user. Cisco Bug IDs: CSCvc90280. | |||||
| CVE-2017-6757 | 1 Cisco | 1 Unified Communications Manager | 2019-10-09 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability in Cisco Unified Communications Manager 10.5(2.10000.5), 11.0(1.10000.10), and 11.5(1.10000.6) could allow an authenticated, remote attacker to conduct a blind SQL injection attack. The vulnerability is due to a failure to validate user-supplied input used in SQL queries that bypass protection filters. An attacker could exploit this vulnerability by sending crafted URLs that include SQL statements. An exploit could allow the attacker to modify or delete entries in some database tables, affecting the integrity of the data. Cisco Bug IDs: CSCve13786. | |||||
| CVE-2017-6763 | 1 Cisco | 1 Meeting Server | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability in the implementation of the H.264 protocol in Cisco Meeting Server (CMS) 2.1.4 could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected system. The vulnerability exists because the affected application does not properly validate Fragmentation Unit (FU-A) protocol packets. An attacker could exploit this vulnerability by sending a crafted H.264 FU-A packet through the affected application. A successful exploit could allow the attacker to cause a DoS condition on the affected system due to an unexpected restart of the CMS media process on the system. Although the CMS platform continues to operate and only the single, affected CMS media process is restarted, a brief interruption of media traffic for certain users could occur. Cisco Bug IDs: CSCve10131. | |||||
| CVE-2017-6766 | 1 Cisco | 1 Firesight System Software | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability in the Secure Sockets Layer (SSL) Decryption and Inspection feature of Cisco Firepower System Software 5.4.0, 5.4.1, 6.0.0, 6.1.0, 6.2.0, 6.2.1, and 6.2.2 could allow an unauthenticated, remote attacker to bypass the SSL policy for decrypting and inspecting traffic on an affected system. The vulnerability is due to unexpected interaction with Known Key and Decrypt and Resign configuration settings of SSL policies when the affected software receives unexpected SSL packet headers. An attacker could exploit this vulnerability by sending a crafted SSL packet through an affected device in a valid SSL session. A successful exploit could allow the attacker to bypass the SSL decryption and inspection policy for the affected system, which could allow traffic to flow through the system without being inspected. Cisco Bug IDs: CSCve12652. | |||||
| CVE-2017-6779 | 1 Cisco | 13 Emergency Responder, Finesse, Hosted Collaboration Mediation Fulfillment and 10 more | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| Multiple Cisco products are affected by a vulnerability in local file management for certain system log files of Cisco collaboration products that could allow an unauthenticated, remote attacker to cause high disk utilization, resulting in a denial of service (DoS) condition. The vulnerability occurs because a certain system log file does not have a maximum size restriction. Therefore, the file is allowed to consume the majority of available disk space on the appliance. An attacker could exploit this vulnerability by sending crafted remote connection requests to the appliance. Successful exploitation could allow the attacker to increase the size of a system log file so that it consumes most of the disk space. The lack of available disk space could lead to a DoS condition in which the application functions could operate abnormally, making the appliance unstable. This vulnerability affects the following Cisco Voice Operating System (VOS)-based products: Emergency Responder, Finesse, Hosted Collaboration Mediation Fulfillment, MediaSense, Prime License Manager, SocialMiner, Unified Communications Manager (UCM), Unified Communications Manager IM and Presence Service (IM&P - earlier releases were known as Cisco Unified Presence), Unified Communication Manager Session Management Edition (SME), Unified Contact Center Express (UCCx), Unified Intelligence Center (UIC), Unity Connection, Virtualized Voice Browser. This vulnerability also affects Prime Collaboration Assurance and Prime Collaboration Provisioning. Cisco Bug IDs: CSCvd10872, CSCvf64322, CSCvf64332, CSCvi29538, CSCvi29543, CSCvi29544, CSCvi29546, CSCvi29556, CSCvi29571, CSCvi31738, CSCvi31741, CSCvi31762, CSCvi31807, CSCvi31818, CSCvi31823. | |||||
| CVE-2017-6780 | 1 Cisco | 2 Connected Grid Network Management System, Iot Field Network Director | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164. | |||||
| CVE-2017-6791 | 1 Cisco | 1 Unified Communications Manager | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability in the Trust Verification Service (TVS) of Cisco Unified Communications Manager could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to improper handling of Transport Layer Security (TLS) traffic by the affected software. An attacker could exploit this vulnerability by generating incomplete traffic streams. A successful exploit could allow the attacker to deny access to the TVS for an affected device, resulting in a DoS condition, until an administrator restarts the service. Known Affected Releases 10.0(1.10000.24) 10.5(2.10000.5) 11.0(1.10000.10) 9.1(2.10000.28). Cisco Bug IDs: CSCux21905. | |||||
| CVE-2017-6870 | 1 Siemens | 1 Simatic Wincc Sm\@rtclient | 2019-10-09 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. | |||||
| CVE-2017-6873 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2019-10-09 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. | |||||
| CVE-2017-6924 | 1 Drupal | 1 Drupal | 2019-10-09 | 5.8 MEDIUM | 7.4 HIGH |
| In Drupal 8 prior to 8.3.7; When using the REST API, users without the correct permission can post comments via REST that are approved even if the user does not have permission to post approved comments. This issue only affects sites that have the RESTful Web Services (rest) module enabled, the comment entity REST resource enabled, and where an attacker can access a user account on the site with permissions to post comments, or where anonymous users can post comments. | |||||
| CVE-2017-7423 | 1 Microfocus | 2 Enterprise Developer, Enterprise Server | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| A Cross-Site Request Forgery (CWE-352) vulnerability in esfadmingui in Micro Focus Enterprise Developer and Enterprise Server 2.3, 2.3 Update 1 before Hotfix 8, and 2.3 Update 2 before Hotfix 9 allows remote unauthenticated attackers to forge requests, if this component is configured. This includes creating new privileged credentials, resulting in privilege elevation (CWE-275). Note esfadmingui is not enabled by default. | |||||
| CVE-2017-7435 | 1 Opensuse | 1 Libzypp | 2019-10-09 | 9.3 HIGH | 8.1 HIGH |
| In libzypp before 20170803 it was possible to add unsigned YUM repositories without warning to the user that could lead to man in the middle or malicious servers to inject malicious RPM packages into a users system. | |||||
| CVE-2017-7436 | 1 Opensuse | 1 Libzypp | 2019-10-09 | 9.3 HIGH | 8.1 HIGH |
| In libzypp before 20170803 it was possible to retrieve unsigned packages without a warning to the user which could lead to man in the middle or malicious servers to inject malicious RPM packages into a users system. | |||||
| CVE-2017-7468 | 1 Haxx | 1 Libcurl | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| In curl and libcurl 7.52.0 to and including 7.53.1, libcurl would attempt to resume a TLS session even if the client certificate had changed. That is unacceptable since a server by specification is allowed to skip the client certificate check on resume, and may instead use the old identity which was established by the previous certificate (or no certificate). libcurl supports by default the use of TLS session id/ticket to resume previous TLS sessions to speed up subsequent TLS handshakes. They are used when for any reason an existing TLS connection couldn't be kept alive to make the next handshake faster. This flaw is a regression and identical to CVE-2016-5419 reported on August 3rd 2016, but affecting a different version range. | |||||
| CVE-2017-7482 | 3 Debian, Linux, Redhat | 3 Debian Linux, Linux Kernel, Enterprise Mrg | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| In the Linux kernel before version 4.12, Kerberos 5 tickets decoded when using the RXRPC keys incorrectly assumes the size of a field. This could lead to the size-remaining variable wrapping and the data pointer going over the end of the buffer. This could possibly lead to memory corruption and possible privilege escalation. | |||||
| CVE-2017-7496 | 1 Fedoraproject | 1 Arm Installer | 2019-10-09 | 4.4 MEDIUM | 7.0 HIGH |
| fedora-arm-installer up to and including 1.99.16 is vulnerable to local privilege escalation due to lack of checking the error condition of mount operation failure on unsafely created temporary directories. | |||||
| CVE-2017-7500 | 1 Rpm | 1 Rpm | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| It was found that rpm did not properly handle RPM installations when a destination path was a symbolic link to a directory, possibly changing ownership and permissions of an arbitrary directory, and RPM files being placed in an arbitrary destination. An attacker, with write access to a directory in which a subdirectory will be installed, could redirect that directory to an arbitrary location and gain root privilege. | |||||
| CVE-2017-7505 | 1 Theforeman | 1 Foreman | 2019-10-09 | 6.5 MEDIUM | 8.8 HIGH |
| Foreman since version 1.5 is vulnerable to an incorrect authorization check due to which users with user management permission who are assigned to some organization(s) can do all operations granted by these permissions on all administrator user object outside of their scope, such as editing global admin accounts including changing their passwords. | |||||
| CVE-2017-7518 | 4 Canonical, Debian, Linux and 1 more | 9 Ubuntu Linux, Debian Linux, Linux Kernel and 6 more | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
| A flaw was found in the Linux kernel before version 4.12 in the way the KVM module processed the trap flag(TF) bit in EFLAGS during emulation of the syscall instruction, which leads to a debug exception(#DB) being raised in the guest stack. A user/process inside a guest could use this flaw to potentially escalate their privileges inside the guest. Linux guests are not affected by this. | |||||
| CVE-2017-7523 | 1 Cygwin | 1 Cygwin | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| Cygwin versions 1.7.2 up to and including 1.8.0 are vulnerable to buffer overflow vulnerability in wcsxfrm/wcsxfrm_l functions resulting into denial-of-service by crashing the process or potential hijack of the process running with administrative privileges triggered by specially crafted input string. | |||||
| CVE-2017-7524 | 1 Tpm2-tools Project | 1 Tpm2.0-tools | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| tpm2-tools versions before 1.1.1 are vulnerable to a password leak due to transmitting password in plaintext from client to server when generating HMAC. | |||||
| CVE-2017-7530 | 1 Redhat | 2 Cloudforms, Cloudforms Management Engine | 2019-10-09 | 6.5 MEDIUM | 8.8 HIGH |
| In CloudForms Management Engine (cfme) before 5.7.3 and 5.8.x before 5.8.1, it was found that privilege check is missing when invoking arbitrary methods via filtering on VMs that MiqExpression will execute that is triggerable by API users. An attacker could use this to execute actions they should not be allowed to (e.g. destroying VMs). | |||||
| CVE-2017-7537 | 2 Dogtagpki, Redhat | 4 Dogtagpki, Enterprise Linux Desktop, Enterprise Linux Server and 1 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| It was found that a mock CMC authentication plugin with a hardcoded secret was accidentally enabled by default in the pki-core package before 10.6.4. An attacker could potentially use this flaw to bypass the regular authentication process and trick the CA server into issuing certificates. | |||||
| CVE-2017-7556 | 1 Hawt | 1 Hawtio | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| Hawtio versions up to and including 1.5.3 are vulnerable to CSRF vulnerability allowing remote attackers to trick the user to visit their website containing a malicious script which can be submitted to hawtio server on behalf of the user. | |||||
| CVE-2017-7557 | 1 Powerdns | 1 Dnsdist | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| dnsdist version 1.1.0 is vulnerable to a flaw in authentication mechanism for REST API potentially allowing CSRF attack. | |||||
| CVE-2017-7558 | 2 Debian, Linux | 2 Debian Linux, Linux Kernel | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A kernel data leak due to an out-of-bound read was found in the Linux kernel in inet_diag_msg_sctp{,l}addr_fill() and sctp_get_sctp_info() functions present since version 4.7-rc1 through version 4.13. A data leak happens when these functions fill in sockaddr data structures used to export socket's diagnostic information. As a result, up to 100 bytes of the slab data could be leaked to a userspace. | |||||
| CVE-2017-7651 | 2 Debian, Eclipse | 2 Debian Linux, Mosquitto | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| In Eclipse Mosquitto 1.4.14, a user can shutdown the Mosquitto server simply by filling the RAM memory with a lot of connections with large payload. This can be done without authentications if occur in connection phase of MQTT protocol. | |||||
| CVE-2017-7652 | 2 Debian, Eclipse | 2 Debian Linux, Mosquitto | 2019-10-09 | 6.0 MEDIUM | 7.5 HIGH |
| In Eclipse Mosquitto 1.4.14, if a Mosquitto instance is set running with a configuration file, then sending a HUP signal to server triggers the configuration to be reloaded from disk. If there are lots of clients connected so that there are no more file descriptors/sockets available (default limit typically 1024 file descriptors on Linux), then opening the configuration file will fail. | |||||
| CVE-2017-7906 | 1 Abb | 2 Ip Gateway, Ip Gateway Firmware | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user. | |||||
| CVE-2017-7908 | 2 Ge, Gigasoft | 2 Ge Communicator, Proessentials | 2019-10-09 | 6.8 MEDIUM | 7.6 HIGH |
| A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls. | |||||
| CVE-2017-7910 | 1 Digital Canal Structural | 1 Wind Analysis | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be able to run arbitrary code by remotely exploiting an executable to perform a denial-of-service attack. | |||||
| CVE-2017-7914 | 1 Rockwellautomation | 2 Panelview Plus 6 700-1500, Panelview Plus 6 700-1500 Firmware | 2019-10-09 | 7.5 HIGH | 8.6 HIGH |
| A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access. | |||||
| CVE-2017-7917 | 1 Moxa | 12 Oncell 5004-hspa, Oncell 5004-hspa Firmware, Oncell 5104-hsdpa and 9 more | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device. | |||||
| CVE-2017-7920 | 1 Abb | 4 Vsn300, Vsn300 Firmware, Vsn300 For React and 1 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating. | |||||
| CVE-2017-7922 | 1 Cambium Networks | 8 Epmp 1000, Epmp 1000 Firmware, Epmp 1000 Hotspot and 5 more | 2019-10-09 | 6.5 MEDIUM | 7.6 HIGH |
| An Improper Privilege Management issue was discovered in Cambium Networks ePMP. The privileges for SNMP community strings are not properly restricted, which may allow an attacker to gain access to sensitive information and possibly allow for configuration changes. | |||||
| CVE-2017-7924 | 1 Rockwellautomation | 8 1763-l16awa, 1763-l16awa Firmware, 1763-l16bbb and 5 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands (PCCC) packet to the controller that could potentially cause the controller to enter a DoS condition. | |||||
| CVE-2017-7926 | 1 Osisoft | 1 Pi Web Api | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| A Cross-Site Request Forgery issue was discovered in OSIsoft PI Web API versions prior to 2017 (1.9.0). The vulnerability allows cross-site request forgery (CSRF) attacks to occur when an otherwise-unauthorized cross-site request is sent from a browser the server has previously authenticated. | |||||
| CVE-2017-7927 | 1 Dahuasecurity | 30 Ddh-hcvr4xxx, Dh-hcvr4xxx Firmware, Dh-hcvr5xxx and 27 more | 2019-10-09 | 7.5 HIGH | 7.3 HIGH |
| A Use of Password Hash Instead of Password for Authentication issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The use of password hash instead of password for authentication vulnerability was identified, which could allow a malicious user to bypass authentication without obtaining the actual password. | |||||
| CVE-2017-7929 | 1 Advantech | 1 Webaccess | 2019-10-09 | 5.5 MEDIUM | 7.1 HIGH |
| An Absolute Path Traversal issue was discovered in Advantech WebAccess Version 8.1 and prior. The absolute path traversal vulnerability has been identified, which may allow an attacker to traverse the file system to access restricted files or directories. | |||||
| CVE-2017-7930 | 1 Osisoft | 1 Pi Data Archive | 2019-10-09 | 5.8 MEDIUM | 7.4 HIGH |
| An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Data Archive has protocol flaws with the potential to expose change records in the clear and allow a malicious party to spoof a server within a collective. | |||||
| CVE-2017-5170 | 1 Moxa | 1 Softnvr-ia Live View | 2019-10-09 | 6.5 MEDIUM | 7.2 HIGH |
| An Uncontrolled Search Path Element issue was discovered in Moxa SoftNVR-IA Live Viewer, Version 3.30.3122 and prior versions. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. The attacker needs to have administrative access to the default install location in order to plant the insecure DLL. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. | |||||
| CVE-2017-5175 | 1 Advantech | 1 Webaccess | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| Advantech WebAccess 8.1 and earlier contains a DLL hijacking vulnerability which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code. | |||||
| CVE-2017-5176 | 1 Rockwellautomation | 8 9328-ccwdevdee, 9328-ccwdevene, 9328-ccwdevese and 5 more | 2019-10-09 | 6.2 MEDIUM | 7.0 HIGH |
| A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. | |||||
| CVE-2017-5187 | 1 Microfocus | 4 Directory Server, Enterprise Developer, Enterprise Server and 1 more | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| A Cross-Site Request Forgery (CWE-352) vulnerability in Directory Server (aka Enterprise Server Administration web UI) in Micro Focus Enterprise Developer and Enterprise Server 2.3 and earlier, 2.3 Update 1 before Hotfix 8, and 2.3 Update 2 before Hotfix 9 allows remote unauthenticated attackers to view and alter (CWE-275) configuration information and inject OS commands (CWE-78) via forged requests. | |||||
| CVE-2017-5188 | 1 Opensuse | 1 Open Build Service | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| The bs_worker code in open build service before 20170320 followed relative symlinks, allowing reading of files outside of the package source directory during build, allowing leakage of private information. | |||||
| CVE-2017-5189 | 1 Netiq | 1 Imanager | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance. | |||||
| CVE-2017-5243 | 1 Rapid7 | 1 Nexpose | 2019-10-09 | 6.8 MEDIUM | 8.5 HIGH |
| The default SSH configuration in Rapid7 Nexpose hardware appliances shipped before June 2017 does not specify desired algorithms for key exchange and other important functions. As a result, it falls back to allowing ALL algorithms supported by the relevant version of OpenSSH and makes the installations vulnerable to a range of MITM, downgrade, and decryption attacks. | |||||
| CVE-2017-5251 | 1 Insteon | 2 Insteon Hub, Insteon Hub Firmware | 2019-10-09 | 6.8 MEDIUM | 8.1 HIGH |
| In version 1012 and prior of Insteon's Insteon Hub, the radio transmissions used for communication between the hub and connected devices are not encrypted. | |||||
| CVE-2017-5254 | 1 Cambiumnetworks | 4 Epmp 1000, Epmp 1000 Firmware, Epmp 2000 and 1 more | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| In version 3.5 and prior of Cambium Networks ePMP firmware, the non-administrative users 'installer' and 'home' have the capability of changing passwords for other accounts, including admin, after disabling a client-side protection mechanism. | |||||
| CVE-2017-5255 | 1 Cambiumnetworks | 4 Epmp 1000, Epmp 1000 Firmware, Epmp 2000 and 1 more | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| In version 3.5 and prior of Cambium Networks ePMP firmware, a lack of input sanitation for certain parameters on the web management console allows any authenticated user (including the otherwise low-privilege readonly user) to inject shell meta-characters as part of a specially-crafted POST request to the get_chart function and run OS-level commands, effectively as root. | |||||