Vulnerabilities (CVE)

Filtered by vendor Ge Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-5908 4 Ge, Ptc, Rockwellautomation and 1 more 8 Industrial Gateway Server, Keepserverex, Opc-aggregator and 5 more 2023-12-06 N/A 9.1 CRITICAL
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
CVE-2023-5909 4 Ge, Ptc, Rockwellautomation and 1 more 8 Industrial Gateway Server, Keepserverex, Opc-aggregator and 5 more 2023-12-06 N/A 7.5 HIGH
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
CVE-2023-0898 1 Ge 1 Micom S1 Agile 2023-11-14 N/A 7.3 HIGH
General Electric MiCOM S1 Agile is vulnerable to an attacker achieving code execution by placing malicious DLL files in the directory of the application.
CVE-2023-3463 1 Ge 1 Cimplicity 2023-07-28 N/A 9.8 CRITICAL
All versions of GE Digital CIMPLICITY that are not adhering to SDG guidance and accepting documents from untrusted sources are vulnerable to memory corruption issues due to insufficient input validation, including issues such as out-of-bounds reads and writes, use-after-free, stack-based buffer overflows, uninitialized pointers, and a heap-based buffer overflow. Successful exploitation could allow an attacker to execute arbitrary code.
CVE-2021-27438 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2022-07-29 6.5 MEDIUM 8.8 HIGH
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2020-36549 1 Ge 2 Voluson S8, Voluson S8 Firmware 2022-06-30 7.2 HIGH 7.8 HIGH
A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed.
CVE-2020-36548 1 Ge 2 Voluson S8, Voluson S8 Firmware 2022-06-30 7.2 HIGH 7.8 HIGH
A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host.
CVE-2020-36547 1 Ge 2 Voluson S8, Voluson S8 Firmware 2022-06-30 7.2 HIGH 7.8 HIGH
A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings.
CVE-2016-5787 1 Ge 1 Cimplicity 2022-02-03 4.6 MEDIUM 6.3 MEDIUM
General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors.
CVE-2016-9360 1 Ge 3 Cimplicity, Historian, Ifix 2022-02-03 4.4 MEDIUM 6.7 MEDIUM
An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session.
CVE-2020-16244 1 Ge 1 Asset Performance Management Classic 2021-11-22 4.0 MEDIUM 7.2 HIGH
GE Digital APM Classic, Versions 4.4 and prior. Salt is not used for hash calculation of passwords, making it possible to decrypt passwords. This design flaw, along with the IDOR vulnerability, puts the entire platform at high risk because an authenticated user can retrieve all user account data and then retrieve the actual passwords.
CVE-2018-5473 1 Ge 2 D60 Line Distance Relay, D60 Line Distance Relay Firmware 2021-08-18 10.0 HIGH 9.8 CRITICAL
An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote attacker to execute arbitrary code on the device.
CVE-2021-31477 1 Ge 2 Reason Rpv311 Firmware, Rpv311 2021-06-24 7.5 HIGH 7.3 HIGH
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852.
CVE-2021-27440 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2021-03-30 7.5 HIGH 9.8 CRITICAL
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2021-27454 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2021-03-30 4.6 MEDIUM 7.8 HIGH
The software performs an operation at a privilege level higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2021-27450 1 Ge 2 Mu320e, Mu320e Firmware 2021-03-29 4.6 MEDIUM 7.8 HIGH
SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1).
CVE-2016-2310 1 Ge 8 Multilink Firmware, Multilink Ml1200, Multilink Ml1600 and 5 more 2021-03-29 10.0 HIGH 9.8 CRITICAL
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
CVE-2021-27452 1 Ge 2 Mu320e, Mu320e Firmware 2021-03-29 10.0 HIGH 9.8 CRITICAL
The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1).
CVE-2021-27448 1 Ge 2 Mu320e, Mu320e Firmware 2021-03-29 4.6 MEDIUM 7.8 HIGH
A miscommunication in the file system allows adversaries with access to the MU320E to escalate privileges on the MU320E (all firmware versions prior to v04A00.1).
CVE-2019-18255 1 Ge 1 Ifix 2021-02-24 2.1 LOW 5.5 MEDIUM
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.
CVE-2019-18243 1 Ge 1 Ifix 2021-02-24 2.1 LOW 5.5 MEDIUM
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through the registry. This may allow privilege escalation.
CVE-2020-27265 4 Ge, Ptc, Rockwellautomation and 1 more 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more 2021-01-21 7.5 HIGH 9.8 CRITICAL
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
CVE-2020-27267 4 Ge, Ptc, Rockwellautomation and 1 more 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more 2021-01-21 6.4 MEDIUM 9.1 CRITICAL
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
CVE-2020-27263 4 Ge, Ptc, Rockwellautomation and 1 more 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more 2021-01-21 6.4 MEDIUM 9.1 CRITICAL
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
CVE-2020-16246 1 Ge 4 S2020, S2020 Firmware, S2024 and 1 more 2020-11-16 4.3 MEDIUM 6.1 MEDIUM
The affected Reason S20 Ethernet Switch is vulnerable to cross-site scripting (XSS), which may allow attackers to trick users into following a link or navigating to a page that posts a malicious JavaScript statement to the vulnerable site, causing the malicious JavaScript to be rendered by the site and executed by the victim client.
CVE-2020-16242 1 Ge 4 S2020, S2020 Firmware, S2024 and 1 more 2020-10-20 4.3 MEDIUM 6.1 MEDIUM
The affected Reason S20 Ethernet Switch is vulnerable to cross-site scripting (XSS), which may allow an attacker to trick application users into performing critical application actions that include, but are not limited to, adding and updating accounts.
CVE-2019-6566 1 Ge 1 Ge Communicator 2020-10-16 7.2 HIGH 7.8 HIGH
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system.
CVE-2019-6544 1 Ge 1 Ge Communicator 2020-10-16 6.8 MEDIUM 5.6 MEDIUM
GE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform certain administrative actions, which may allow the execution of scheduled scripts with system administrator privileges. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
CVE-2019-13554 1 Ge 1 Mark Vie Control System 2020-10-09 6.5 MEDIUM 8.8 HIGH
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service.
CVE-2020-16240 1 Ge 1 Asset Performance Management Classic 2020-10-05 5.0 MEDIUM 5.3 MEDIUM
GE Digital APM Classic, Versions 4.4 and prior. An insecure direct object reference (IDOR) vulnerability allows user account data to be downloaded in JavaScript object notation (JSON) format by users who should not have access to such functionality. An attacker can download sensitive data related to user accounts without having the proper privileges.
CVE-2019-10966 1 Ge 8 Aespire 7100, Aespire 7100 Firmware, Aespire 7900 and 5 more 2020-10-02 5.0 MEDIUM 5.3 MEDIUM
In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.
CVE-2018-5475 1 Ge 2 D60 Line Distance Relay, D60 Line Distance Relay Firmware 2020-09-18 7.5 HIGH 9.8 CRITICAL
A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.
CVE-2020-12017 1 Ge 6 Rt430, Rt430 Firmware, Rt431 and 3 more 2020-06-08 9.0 HIGH 9.8 CRITICAL
GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.
CVE-2020-6992 1 Ge 1 Cimplicity 2020-04-22 4.6 MEDIUM 6.7 MEDIUM
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
CVE-2019-13559 1 Ge 1 Mark Vie Controll System 2020-04-08 7.2 HIGH 7.8 HIGH
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
CVE-2020-6977 1 Ge 32 Invenia Abus Scan Station, Invenia Abus Scan Station Firmware, Logiq E10 and 29 more 2020-03-05 7.2 HIGH 6.8 MEDIUM
A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5
CVE-2012-6663 1 Ge 4 D200, D200 Firmware, D20me and 1 more 2020-01-28 5.0 MEDIUM 7.5 HIGH
General Electric D20ME devices are not properly configured and reveal plaintext passwords.
CVE-2019-18267 1 Ge 4 S2020, S2020 Firmware, S2020g and 1 more 2020-01-07 3.5 LOW 5.4 MEDIUM
An issue was found in GE S2020/S2020G Fast Switch 61850, S2020/S2020G Fast Switch 61850 Versions 07A03 and prior. An attacker can inject arbitrary Javascript in a specially crafted HTTP request that may be reflected back in the HTTP response. The device is also vulnerable to a stored cross-site scripting vulnerability that may allow session hijacking, disclosure of sensitive data, cross-site request forgery (CSRF) attacks, and remote code execution.
CVE-2019-6548 1 Ge 1 Ge Communicator 2019-10-09 6.8 MEDIUM 8.1 HIGH
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
CVE-2019-6564 1 Ge 1 Ge Communicator 2019-10-09 9.3 HIGH 7.8 HIGH
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to place malicious files within the installer file directory, which may allow an attacker to gain administrative privileges on a system during installation or upgrade.
CVE-2019-6546 1 Ge 1 Ge Communicator 2019-10-09 6.8 MEDIUM 7.8 HIGH
GE Communicator, all versions prior to 4.0.517, allows an attacker to place malicious files within the working directory of the program, which may allow an attacker to manipulate widgets and UI elements.
CVE-2018-8867 1 Ge 16 Pacsystems Cpu320, Pacsystems Cpu320 Firmware, Pacsystems Cru320 and 13 more 2019-10-09 7.8 HIGH 7.5 HIGH
In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow a remote attacker to send specially crafted packets causing the device to become unavailable.
CVE-2018-19003 1 Ge 6 Ex2100e, Ex2100e Firmware, Ls2100e and 3 more 2019-10-09 5.0 MEDIUM 7.5 HIGH
GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.
CVE-2018-17925 1 Ge 1 Ifix 2019-10-09 4.4 MEDIUM 4.8 MEDIUM
Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted.
CVE-2018-10611 1 Ge 1 Mds Pulsenet 2019-10-09 7.5 HIGH 9.8 CRITICAL
Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
CVE-2018-10613 1 Ge 1 Mds Pulsenet 2019-10-09 5.0 MEDIUM 7.5 HIGH
Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
CVE-2018-10615 1 Ge 1 Mds Pulsenet 2019-10-09 6.5 MEDIUM 8.1 HIGH
Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.
CVE-2017-7905 1 Ge 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more 2019-10-09 5.0 MEDIUM 9.8 CRITICAL
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
CVE-2017-7908 2 Ge, Gigasoft 2 Ge Communicator, Proessentials 2019-10-09 6.8 MEDIUM 7.6 HIGH
A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls.
CVE-2017-14006 1 Ge 1 Xeleris 2019-10-09 7.5 HIGH 9.8 CRITICAL
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.