Vulnerabilities (CVE)

CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-18591 1 Microfocus 1 Service Manager 2019-10-09 4.0 MEDIUM 6.5 MEDIUM
A potential unauthorized disclosure of data vulnerability has been identified in Micro Focus Service Manager versions: 9.30, 9.31, 9.32, 9.33, 9.34, 9.35, 9.40, 9.41, 9.50, 9.51. The vulnerability could be exploited to release unauthorized disclosure of data.
CVE-2018-18593 1 Hp 1 Ucmdb Configuration Manager 2019-10-09 5.0 MEDIUM 7.5 HIGH
Remote Directory Traversal and Remote Disclosure of Privileged Information in UCMDB Configuration Management Service, version 10.22, 10.22 CUP1, 10.22 CUP2, 10.22 CUP3, 10.22 CUP4, 10.22 CUP5, 10.22 CUP6, 10.22 CUP7, 10.33, 10.33 CUP1, 10.33 CUP2, 10.33 CUP3, 2018.02, 2018.05, 2018.08, 2018.11. The vulnerabilities could allow Remote Directory Traversal and Remote Disclosure of Privileged Information
CVE-2018-18807 1 Tibco 1 Statistica Server 2019-10-09 3.5 LOW 5.4 MEDIUM
The web application of the TIBCO Statistica component of TIBCO Software Inc.'s TIBCO Statistica Server contains vulnerabilities which may allow an authenticated user to perform cross-site scripting (XSS) attacks. Affected releases are TIBCO Software Inc.'s TIBCO Statistica Server versions up to and including 13.4.0.
CVE-2018-18808 1 Tibco 3 Jasperreports Server, Jaspersoft, Jaspersoft Reporting And Analytics 2019-10-09 8.5 HIGH 7.5 HIGH
The domain management component of TIBCO Software Inc.'s TIBCO JasperReports Server, TIBCO JasperReports Server Community Edition, TIBCO JasperReports Server for ActiveMatrix BPM, TIBCO Jaspersoft for AWS with Multi-Tenancy, and TIBCO Jaspersoft Reporting and Analytics for AWS contains a race-condition vulnerability that may allow any users with domain save privileges to gain superuser privileges. Affected releases are TIBCO Software Inc.'s TIBCO JasperReports Server: versions up to and including 6.3.4; 6.4.0; 6.4.1; 6.4.2; 6.4.3; 7.1.0, TIBCO JasperReports Server Community Edition: versions up to and including 7.1.0, TIBCO JasperReports Server for ActiveMatrix BPM: versions up to and including 6.4.3, TIBCO Jaspersoft for AWS with Multi-Tenancy: versions up to and including 7.1.0, and TIBCO Jaspersoft Reporting and Analytics for AWS: versions up to and including 7.1.0.
CVE-2018-18813 1 Tibco 2 Spotfire Analytics Platform For Aws, Spotfire Server 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
The Spotfire web server component of TIBCO Software Inc.'s TIBCO Spotfire Analytics Platform for AWS Marketplace, and TIBCO Spotfire Server contains multiple vulnerabilities that may allow persistent and reflected cross-site scripting attacks. Affected releases are TIBCO Software Inc. TIBCO Spotfire Analytics Platform for AWS Marketplace: versions up to and including 10.0.0, and TIBCO Spotfire Server: versions up to and including 7.10.1; 7.11.0; 7.11.1; 7.12.0; 7.13.0; 7.14.0; 10.0.0.
CVE-2018-18814 1 Tibco 2 Spotfire Analytics Platform For Aws, Spotfire Server 2019-10-09 7.5 HIGH 9.8 CRITICAL
The TIBCO Spotfire authentication component of TIBCO Software Inc.'s TIBCO Spotfire Analytics Platform for AWS Marketplace, and TIBCO Spotfire Server contains a vulnerability in the handling of the authentication that theoretically may allow an attacker to gain full access to a target account, independent of configured authentication mechanisms. Affected releases are TIBCO Software Inc. TIBCO Spotfire Analytics Platform for AWS Marketplace: versions up to and including 10.0.0, and TIBCO Spotfire Server: versions up to and including 7.10.1; 7.11.0; 7.11.1; 7.12.0; 7.13.0; 7.14.0.
CVE-2018-18816 1 Tibco 3 Jasperreports Server, Jaspersoft, Jaspersoft Reporting And Analytics 2019-10-09 3.5 LOW 5.4 MEDIUM
The repository component of TIBCO Software Inc.'s TIBCO JasperReports Server, TIBCO JasperReports Server Community Edition, TIBCO JasperReports Server for ActiveMatrix BPM, TIBCO Jaspersoft for AWS with Multi-Tenancy, TIBCO Jaspersoft Reporting and Analytics for AWS contains a persistent cross site scripting vulnerability. Affected releases are TIBCO Software Inc.'s TIBCO JasperReports Server: versions up to and including 6.3.4; 6.4.0; 6.4.1; 6.4.2; 6.4.3; 7.1.0, TIBCO JasperReports Server Community Edition: versions up to and including 7.1.0, TIBCO JasperReports Server for ActiveMatrix BPM: versions up to and including 6.4.3, TIBCO Jaspersoft for AWS with Multi- Tenancy versions up to and including 7.1.0, and TIBCO Jaspersoft Reporting and Analytics for AWS: versions up to and including 7.1.0.
CVE-2018-18981 1 Rockwellautomation 1 Factorytalk Services Platform 2019-10-09 7.8 HIGH 7.5 HIGH
In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services.
CVE-2018-18982 1 Nuuo 1 Nuuo Cms 2019-10-09 6.5 MEDIUM 8.8 HIGH
NUUO CMS All versions 3.3 and prior the web server application allows injection of arbitrary SQL characters, which can be used to inject SQL into an executing statement and allow arbitrary code execution.
CVE-2018-18985 1 Tridium 3 Niagara, Niagara Ax Framework, Niagara Enterprise Security 2019-10-09 3.5 LOW 5.4 MEDIUM
Tridium Niagara Enterprise Security 2.3u1, all versions prior to 2.3.118.6, Niagara AX 3.8u4, all versions prior to 3.8.401.1, Niagara 4.4u2, all versions prior to 4.4.93.40.2, and Niagara 4.6, all versions prior to 4.6.96.28.4 a cross-site scripting vulnerability has been identified that may allow a remote attacker to inject code to some web pages affecting confidentiality.
CVE-2018-18986 1 Lcds 1 Laquis Scada 2019-10-09 8.3 HIGH 7.8 HIGH
LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.
CVE-2018-18988 1 Lcds 1 Laquis Scada 2019-10-09 8.3 HIGH 8.8 HIGH
LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash.
CVE-2018-18989 1 Omron 3 Cx-one, Cx-programmer, Cx-server 2019-10-09 6.8 MEDIUM 7.8 HIGH
In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-18990 1 Lcds 1 Laquis Scada 2019-10-09 5.0 MEDIUM 5.3 MEDIUM
LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.
CVE-2018-18991 1 Spidercontrol 1 Scada Webserver 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
Reflected cross-site scripting (non-persistent) in SCADA WebServer (Versions prior to 2.03.0001) could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser.
CVE-2018-18992 1 Lcds 1 Laquis Scada 2019-10-09 6.8 MEDIUM 8.8 HIGH
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.
CVE-2018-18994 1 Laquisscada 1 Laquis Scada 2019-10-09 7.8 HIGH 7.1 HIGH
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration.
CVE-2018-18995 1 Abb 4 Gate-e1, Gate-e1 Firmware, Gate-e2 and 1 more 2019-10-09 7.5 HIGH 9.8 CRITICAL
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
CVE-2018-18996 1 Lcds 1 Laquis Scada 2019-10-09 7.5 HIGH 9.8 CRITICAL
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.
CVE-2018-18997 1 Abb 4 Gate-e1, Gate-e1 Firmware, Gate-e2 and 1 more 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
Pluto Safety PLC Gateway Ethernet devices in ABB GATE-E1 and GATE-E2 all versions allows an unauthenticated attacker using the administrative web interface to insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor browser.
CVE-2018-18998 1 Lcds 1 Laquis Scada 2019-10-09 7.5 HIGH 9.8 CRITICAL
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
CVE-2018-19000 1 Lcds 1 Laquis Scada 2019-10-09 5.0 MEDIUM 5.3 MEDIUM
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.
CVE-2018-19001 1 Philips 1 Healthsuite Health 2019-10-09 4.6 MEDIUM 4.3 MEDIUM
Philips HealthSuite Health Android App, all versions. The software uses simple encryption that is not strong enough for the level of protection required.
CVE-2018-19002 1 Lcds 1 Laquis Scada 2019-10-09 8.3 HIGH 7.8 HIGH
LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.
CVE-2018-19003 1 Ge 6 Ex2100e, Ex2100e Firmware, Ls2100e and 3 more 2019-10-09 5.0 MEDIUM 7.5 HIGH
GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.
CVE-2018-19004 1 Lcds 1 Laquis Scada 2019-10-09 4.3 MEDIUM 3.3 LOW
LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration.
CVE-2018-19005 1 Hornerautomation 1 Cscape 2019-10-09 6.8 MEDIUM 7.8 HIGH
Cscape, Version 9.80.75.3 SP3 and prior. An improper input validation vulnerability has been identified that may be exploited by processing specially crafted POC files lacking user input validation. This may allow an attacker to read confidential information and remotely execute arbitrary code.
CVE-2018-19006 1 Osisoft 1 Pi Vision 2019-10-09 3.5 LOW 4.8 MEDIUM
OSIsoft PI Vision, versions PI Vision 2017, and PI Vision 2017 R2, The application contains a cross-site scripting vulnerability where displays that reference AF elements and attributes containing JavaScript are affected. This vulnerability requires the ability of authorized AF users to store JavaScript in AF elements and attributes.
CVE-2018-19007 1 Geutebrueck 4 G-cam\/efd-2251, G-cam\/efd-2251 Firmware, G-cam\/ewpc-2275 and 1 more 2019-10-09 10.0 HIGH 9.8 CRITICAL
In Geutebrueck GmbH E2 Camera Series versions prior to 1.12.0.25 the DDNS configuration (in the Network Configuration panel) is vulnerable to an OS system command injection as root.
CVE-2018-19008 1 Abb 2 Cp400pb, Cp400pb Firmware 2019-10-09 6.8 MEDIUM 7.8 HIGH
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
CVE-2018-19010 1 Draeger 8 Delta Xl, Delta Xl Firmware, Infinity Delta and 5 more 2019-10-09 3.3 LOW 6.5 MEDIUM
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.
CVE-2018-19011 1 Omron 1 Cx-supervisor 2019-10-09 6.8 MEDIUM 8.8 HIGH
CX-Supervisor (Versions 3.42 and prior) can execute code that has been injected into a project file. An attacker could exploit this to execute code under the privileges of the application.
CVE-2018-19012 1 Draeger 8 Delta Xl, Delta Xl Firmware, Infinity Delta and 5 more 2019-10-09 7.2 HIGH 7.8 HIGH
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker is able to take control of the operating system.
CVE-2018-19013 1 Omron 1 Cx-supervisor 2019-10-09 4.9 MEDIUM 5.0 MEDIUM
An attacker could inject commands to delete files and/or delete the contents of a file on CX-Supervisor (Versions 3.42 and prior) through a specially crafted project file.
CVE-2018-19014 1 Draeger 8 Delta Xl, Delta Xl Firmware, Infinity Delta and 5 more 2019-10-09 3.3 LOW 6.5 MEDIUM
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the patient monitor, the location of the monitor, and wired network configuration.
CVE-2018-19016 1 Rockwellautomation 2 Ethernet\/ip Web Server Module 1756-eweb, Ethernet\/ip Web Server Module 1768-eweb 2019-10-09 7.8 HIGH 7.5 HIGH
Rockwell Automation EtherNet/IP Web Server Modules 1756-EWEB (includes 1756-EWEBK) Version 5.001 and earlier, and CompactLogix 1768-EWEB Version 2.005 and earlier. A remote attacker could send a crafted UDP packet to the SNMP service causing a denial-of-service condition to occur until the affected product is restarted.
CVE-2018-19017 1 Omron 1 Cx-supervisor 2019-10-09 6.8 MEDIUM 8.8 HIGH
Several use after free vulnerabilities have been identified in CX-Supervisor (Versions 3.42 and prior). When processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-19018 1 Omron 1 Cx-supervisor 2019-10-09 6.0 MEDIUM 7.3 HIGH
An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-19019 1 Omron 1 Cx-supervisor 2019-10-09 6.8 MEDIUM 7.3 HIGH
A type confusion vulnerability exists when processing project files in CX-Supervisor (Versions 3.42 and prior). An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-19020 1 Omron 1 Cx-supervisor 2019-10-09 3.5 LOW 5.0 MEDIUM
When CX-Supervisor (Versions 3.42 and prior) processes project files and tampers with the value of an offset, an attacker can force the application to read a value outside of an array.
CVE-2018-19023 1 Hetronic 10 Bms-hl, Bms-hl Firmware, Dc Mobile and 7 more 2019-10-09 5.8 MEDIUM 8.8 HIGH
Hetronic Nova-M prior to verson r161 uses fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state.
CVE-2018-19027 1 Omron 2 Cx-one, Cx-protocol 2019-10-09 6.8 MEDIUM 7.8 HIGH
Three type confusion vulnerabilities exist in CX-One Versions 4.50 and prior and CX-Protocol Versions 2.0 and prior when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
CVE-2018-19029 1 Lcds 1 Laquis Scada 2019-10-09 8.3 HIGH 7.8 HIGH
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.
CVE-2018-19276 1 Openmrs 1 Openmrs 2019-10-09 10.0 HIGH 9.8 CRITICAL
OpenMRS before 2.24.0 is affected by an Insecure Object Deserialization vulnerability that allows an unauthenticated user to execute arbitrary commands on the targeted system via crafted XML data in a request body.
CVE-2018-19641 1 Microfocus 1 Solutions Business Manager 2019-10-09 7.5 HIGH 9.8 CRITICAL
Unauthenticated remote code execution issue in Micro Focus Solutions Business Manager (SBM) (formerly Serena Business Manager (SBM)) versions prior to 11.5.
CVE-2018-19642 1 Microfocus 1 Solutions Business Manager 2019-10-09 5.0 MEDIUM 7.5 HIGH
Denial of service issue in Micro Focus Solutions Business Manager (SBM) (formerly Serena Business Manager (SBM)) versions prior to 11.5.
CVE-2018-19643 1 Microfocus 1 Solutions Business Manager 2019-10-09 5.0 MEDIUM 7.5 HIGH
Information leakage issue in Micro Focus Solutions Business Manager (SBM) (formerly Serena Business Manager (SBM)) versions prior to 11.5.
CVE-2018-19644 1 Microfocus 1 Solutions Business Manager 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
Reflected cross site script issue in Micro Focus Solutions Business Manager (SBM) (formerly Serena Business Manager (SBM)) versions prior to 11.5.
CVE-2018-16459 1 Exceljs Project 1 Exceljs 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
An unescaped payload in exceljs <v1.6 allows a possible XSS via cell value when worksheet is displayed in browser.
CVE-2018-16460 1 Umbraengineering 1 Ps 2019-10-09 7.5 HIGH 9.8 CRITICAL
A command Injection in ps package versions <1.0.0 for Node.js allowed arbitrary commands to be executed when attacker controls the PID.