| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2018-7817 | 1 Schneider-electric | 1 Zelio Soft 2 | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| A Use After Free (CWE-416) vulnerability exists in Zelio Soft 2 v5.1 and prior versions which could cause remote code execution when opening a specially crafted Zelio Soft project file. | |||||
| CVE-2018-7820 | 1 Schneider-electric | 8 Ap9630, Ap9630 Firmware, Ap9631 and 5 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled. | |||||
| CVE-2018-7834 | 1 Schneider-electric | 2 Tsxetg100, Tsxetg100 Firmware | 2019-10-09 | 4.3 MEDIUM | 6.1 MEDIUM |
| A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user. | |||||
| CVE-2018-8790 | 1 Checkpoint | 1 Zonealarm | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| Check Point ZoneAlarm version 15.3.064.17729 and below expose a WCF service that can allow a local low privileged user to execute arbitrary code as SYSTEM. | |||||
| CVE-2018-8835 | 1 Advantech | 1 Webaccess Hmi Designer | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| Double free vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution. | |||||
| CVE-2018-8836 | 1 Wago | 16 750-829, 750-829 Firmware, 750-831 and 13 more | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
| Wago 750 Series PLCs with firmware version 10 and prior include a remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port 2455/TCP/IP, used in Codesys management software, which may result in a denial-of-service condition of communications with commissioning and service tools. | |||||
| CVE-2018-8837 | 1 Advantech | 1 Webaccess Hmi Designer | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| Processing specially crafted .pm3 files in Advantech WebAccess HMI Designer 2.1.7.32 and prior may cause the system to write outside the intended buffer area and may allow remote code execution. | |||||
| CVE-2018-8840 | 2 Indusoft, Industrial-software | 2 Web Studio, Intouch Machine Edition 2017 | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution. | |||||
| CVE-2018-8841 | 1 Advantech | 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
| In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user. | |||||
| CVE-2018-8842 | 1 Philips | 1 E-alert Firmware | 2019-10-09 | 3.3 LOW | 8.8 HIGH |
| Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet. | |||||
| CVE-2018-8843 | 1 Rockwellautomation | 1 Arena | 2019-10-09 | 4.3 MEDIUM | 5.5 MEDIUM |
| Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data.. | |||||
| CVE-2018-8844 | 1 Philips | 1 E-alert Firmware | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. | |||||
| CVE-2018-8846 | 1 Philips | 1 E-alert Firmware | 2019-10-09 | 4.3 MEDIUM | 6.1 MEDIUM |
| Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users. | |||||
| CVE-2018-8849 | 1 Medtronic | 4 N\'vision 8840, N\'vision 8840 Firmware, N\'vision 8870 and 1 more | 2019-10-09 | 2.1 LOW | 4.6 MEDIUM |
| Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programmer, all versions, and 8870 N'Vision removable Application Card, all versions does not encrypt PII and PHI while at rest. | |||||
| CVE-2018-8850 | 1 Philips | 1 E-alert Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution. | |||||
| CVE-2018-8851 | 1 Echelon | 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface. | |||||
| CVE-2018-8852 | 1 Philips | 1 E-alert Firmware | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier. | |||||
| CVE-2018-8853 | 1 Philips | 8 Brilliance Ct Big Bore, Brilliance Ct Big Bore Firmware, Brilliance 64 and 5 more | 2019-10-09 | 7.2 HIGH | 8.8 HIGH |
| Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauthorized resources from the underlying Windows operating system. | |||||
| CVE-2018-8854 | 1 Philips | 1 E-alert Firmware | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended. | |||||
| CVE-2018-8855 | 1 Echelon | 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP. | |||||
| CVE-2018-8857 | 1 Philips | 8 Brilliance Ct Big Bore, Brilliance Ct Big Bore Firmware, Brilliance 64 and 5 more | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system. | |||||
| CVE-2018-8858 | 1 Vecna | 2 Vgo, Vgo Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| If an attacker has access to the firmware from the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be able to extract credentials. | |||||
| CVE-2018-8859 | 1 Echelon | 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can bypass the required authentication specified in the security configuration file by including extra characters in the directory name when specifying the directory to be accessed. This vulnerability does not affect the i.LON 600 product. | |||||
| CVE-2018-8861 | 1 Philips | 8 Brilliance Ct Big Bore, Brilliance Ct Big Bore Firmware, Brilliance 64 and 5 more | 2019-10-09 | 6.8 MEDIUM | 8.7 HIGH |
| Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the underlying Windows OS, and access unauthorized resources from the operating system. | |||||
| CVE-2018-8862 | 1 Atisystem | 8 Alert4000, Alert4000 Firmware, Hpss16 and 5 more | 2019-10-09 | 2.9 LOW | 3.1 LOW |
| In ATI Systems Emergency Mass Notification Systems (HPSS16, HPSS32, MHPSS, and ALERT4000) devices, an improper authentication vulnerability caused by specially crafted malicious radio transmissions may allow an attacker to remotely trigger false alarms. | |||||
| CVE-2018-8864 | 1 Atisystem | 8 Alert4000, Alert4000 Firmware, Hpss16 and 5 more | 2019-10-09 | 2.9 LOW | 3.1 LOW |
| In ATI Systems Emergency Mass Notification Systems (HPSS16, HPSS32, MHPSS, and ALERT4000) devices, a missing encryption of sensitive data vulnerability caused by specially crafted malicious radio transmissions may allow an attacker to remotely trigger false alarms. | |||||
| CVE-2018-8867 | 1 Ge | 16 Pacsystems Cpu320, Pacsystems Cpu320 Firmware, Pacsystems Cru320 and 13 more | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow a remote attacker to send specially crafted packets causing the device to become unavailable. | |||||
| CVE-2018-8868 | 1 Medtronic | 4 24950 Mycarelink Monitor, 24950 Mycarelink Monitor Firmware, 24952 Mycarelink Monitor and 1 more | 2019-10-09 | 6.9 MEDIUM | 6.4 MEDIUM |
| Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can apply the other vulnerabilities within this advisory to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality. | |||||
| CVE-2018-8869 | 1 Lantech | 2 Ids 2102, Ids 2102 Firmware | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| In Lantech IDS 2102 2.0 and prior, nearly all input fields allow for arbitrary input on the device. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | |||||
| CVE-2018-8870 | 1 Medtronic | 4 24950 Mycarelink Monitor, 24950 Mycarelink Monitor Firmware, 24952 Mycarelink Monitor and 1 more | 2019-10-09 | 7.2 HIGH | 6.8 MEDIUM |
| Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system. | |||||
| CVE-2018-4834 | 1 Siemens | 10 Pxc001-e.d, Pxc001-e.d Firmware, Pxc00\/50\/100\/200-e.d and 7 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in Desigo Automation Controllers Products and Desigo Operator Unit PXM20-E. A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication. | |||||
| CVE-2018-4835 | 1 Siemens | 1 Telecontrol Server Basic | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information. | |||||
| CVE-2018-4836 | 1 Siemens | 1 Telecontrol Server Basic | 2019-10-09 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations. | |||||
| CVE-2018-4837 | 1 Siemens | 1 Telecontrol Server Basic | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with access to the TeleControl Server Basic's webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition. | |||||
| CVE-2018-4839 | 1 Siemens | 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more | 2019-10-09 | 3.5 LOW | 5.3 MEDIUM |
| A vulnerability has been identified in Siemens DIGSI 4 (All versions < V4.92), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77), SIPROTEC Compact 7SJ66 (All versions < V4.30), Other SIPROTEC Compact relays (All versions), Other SIPROTEC 4 relays (All versions). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords. | |||||
| CVE-2018-4840 | 1 Siemens | 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Siemens DIGSI 4 (All versions < V4.92), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 104 variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords. | |||||
| CVE-2018-4841 | 1 Siemens | 2 Tim 1531 Irc, Tim 1531 Irc Firmware | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it. | |||||
| CVE-2018-4844 | 1 Siemens | 1 Simatic Wincc Oa Ui | 2019-10-09 | 3.8 LOW | 6.7 MEDIUM |
| A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. | |||||
| CVE-2018-4845 | 1 Siemens | 6 Rapidlab 1200, Rapidlab 1200 Firmware, Rapidpoint 400 and 3 more | 2019-10-09 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue. | |||||
| CVE-2018-4846 | 1 Siemens | 6 Rapidlab 1200, Rapidlab 1200 Firmware, Rapidpoint 400 and 3 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue. | |||||
| CVE-2018-4849 | 1 Siemens | 1 Siveillance Vms Video | 2019-10-09 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability has been identified in Siveillance VMS Video for Android (All versions < V12.1a (2018 R1)), Siveillance VMS Video for iOS (All versions < V12.1a (2018 R1)). Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the communication channel between the affected app and a server (such as Man-in-the-Middle). Furthermore, an attacker must be able to generate a certificate that results for the validation algorithm in a checksum identical to a trusted certificate. Successful exploitation requires no user interaction. The vulnerability could allow reading data from and writing data to the encrypted communication channel between the app and a server, impacting the communication's confidentiality and integrity. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue. | |||||
| CVE-2018-4850 | 1 Siemens | 4 Simatic S7-400, Simatic S7-400 Firmware, Simatic S7-400h and 1 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC S7-400 (incl. F) CPU hardware version 4.0 and below (All versions), SIMATIC S7-400 (incl. F) CPU hardware version 5.0 (All firmware versions < V5.2), SIMATIC S7-400H CPU hardware version 4.5 and below (All versions). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. | |||||
| CVE-2018-4851 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2019-10-09 | 8.5 HIGH | 8.2 HIGH |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed. | |||||
| CVE-2018-4852 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device. | |||||
| CVE-2018-4853 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device. | |||||
| CVE-2018-4854 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2019-10-09 | 9.3 HIGH | 8.8 HIGH |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system. | |||||
| CVE-2018-4855 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2019-10-09 | 4.3 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords. | |||||
| CVE-2018-4856 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2019-10-09 | 4.0 MEDIUM | 4.9 MEDIUM |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users. | |||||
| CVE-2018-4859 | 1 Siemens | 2 Scalance M875, Scalance M875 Firmware | 2019-10-09 | 9.0 HIGH | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2018-4860 | 1 Siemens | 2 Scalance M875, Scalance M875 Firmware | 2019-10-09 | 9.0 HIGH | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||