Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2019-10929 1 Siemens 33 Simatic Cp 1626, Simatic Cp 1626 Firmware, Simatic Et 200sp Open Controller Cpu 1515sp Pc and 30 more 2020-10-02 4.3 MEDIUM 5.9 MEDIUM
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions <= 20.8), SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC (All versions), SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC2 (All versions), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software (All versions), SIMATIC S7 PLCSIM Advanced (All versions <= V3.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions <= V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518 MFP (and related SIPLUS variant) (All versions <= V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518-4 PN/DP and CPU 1518 MFP (and related SIPLUS variant) (All versions <= V2.8.1), SIMATIC S7-1500 Software Controller (All versions <= V20.8), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions <= 3.15), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional (All versions), TIM 1531 IRC (incl. SIPLUS variant) (All versions). An attacker in a Man-in-the-Middle position could potentially modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families, due to certain properties in the calculation used for integrity protection. In order to exploit the vulnerability, an attacker must be able to perform a Man-in-the-Middle attack. The vulnerability could impact the integrity of the communication. No public exploitation of the vulnerability was known at the time of advisory publication.
CVE-2019-10928 1 Siemens 2 Scalance Sc-600, Scalance Sc-600 Firmware 2020-10-02 4.6 MEDIUM 6.6 MEDIUM
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
CVE-2020-15785 1 Siemens 1 Siveillance Video Client 2020-09-23 4.3 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in Siveillance Video Client (All versions). In environments where Windows NTLM authentication is enabled the affected client application transmits usernames to the server in cleartext. This could allow an attacker in a privileged network position to obtain valid adminstrator login names and use this information to launch further attacks.
CVE-2020-15788 1 Siemens 1 Polarion Subversion Webclient 2020-09-14 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents Cross-Site Scripting. If a user is enticed into passing specially crafted, malicious input to the web client (e.g. by clicking on a malicious URL with embedded JavaScript), then JavaScript code can be returned and may then be executed by the user’s client. Various actions could be triggered by running malicious JavaScript code.
CVE-2020-15790 1 Siemens 1 Spectrum Power 4 2020-09-14 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). If configured in an insecure manner, the web server might be susceptible to a directory listing attack.
CVE-2020-15784 1 Siemens 1 Spectrum Power 4 2020-09-14 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). Insecure storage of sensitive information in the configuration files could allow the retrieval of user names.
CVE-2020-7576 1 Siemens 1 Opcenter Execution Core 2020-08-14 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2), Opcenter Execution Core (V8.2). An authenticated user with the ability to create containers, packages or register defects could perform stored Cross-Site Scripting (XSS) attacks within the vulnerable software. The impact of this attack could result in the session cookies of legitimate users being stolen. Should the attacker gain access to these cookies, they could then hijack the session and perform arbitrary actions in the name of the victim.
CVE-2020-7592 1 Siemens 9 Simatic Hmi Basic Panels 1st Generation, Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Comfort Panels and 6 more 2020-07-22 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
CVE-2020-10040 1 Siemens 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more 2020-07-15 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with local access to the device might be able to retrieve some passwords in clear text.
CVE-2020-10041 1 Siemens 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more 2020-07-15 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user.
CVE-2020-10043 1 Siemens 6 Sicam Mmu, Sicam Mmu Firmware, Sicam Sgu and 3 more 2020-07-15 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.
CVE-2020-7579 1 Siemens 1 Spectrum Power 5 2020-03-11 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Spectrum Powerâ„¢ 5 (All versions < v5.50 HF02). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. If deployed according to recommended system configuration, Siemens consideres the environmental vector as CR:L/IR:M/AR:H/MAV:A (4.1).
CVE-2016-9159 1 Siemens 21 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 314, Simatic S7-300 Cpu 315-2 Dp and 18 more 2020-03-10 4.3 MEDIUM 5.9 MEDIUM
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
CVE-2016-2201 1 Siemens 15 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1511c-1 Pn Cpu and 12 more 2020-02-10 5.0 MEDIUM 5.3 MEDIUM
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102.
CVE-2018-4842 1 Siemens 6 Scalance X200, Scalance X200 Firmware, Scalance X200 Irt and 3 more 2020-01-16 3.5 LOW 4.8 MEDIUM
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
CVE-2018-4848 1 Siemens 6 Scalance X-200, Scalance X-200 Firmware, Scalance X-200 Irt and 3 more 2020-01-16 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected Scalance X Switches could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
CVE-2019-13927 1 Siemens 32 Pxa30-w0, Pxa30-w0 Firmware, Pxa30-w1 and 29 more 2019-12-30 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server (All firmware versions < V6.00.320). The device contains a vulnerability that could allow an attacker to cause a denial of service condition on the device's web server by sending a specially crafted HTTP message to the web server port (tcp/80). The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device's web service. While the device itself stays operational, the web server responds with HTTP status code 404 (Not found) to any further request. A reboot is required to recover the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13944 1 Siemens 6 En100 Ethernet Module, En100 Ethernet Module With Firmware Variant Dnp3 Tcp, En100 Ethernet Module With Firmware Variant Iec104 and 3 more 2019-12-19 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13943 1 Siemens 6 En100 Ethernet Module, En100 Ethernet Module With Firmware Variant Dnp3 Tcp, En100 Ethernet Module With Firmware Variant Iec104 and 3 more 2019-12-19 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known.
CVE-2019-13931 1 Siemens 1 Xhq 2019-12-19 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow for an an attacker to craft the input in a form that is not expected, causing the application to behave in unexpected ways for legitimate users. Successful exploitation requires for an attacker to be authenticated to the web interface. A successful attack could cause the application to have unexpected behavior. This could allow the attacker to modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2016-8672 1 Siemens 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more 2019-12-12 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission.
CVE-2019-13935 1 Siemens 1 Polarion 2019-12-05 3.5 LOW 5.4 MEDIUM
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13936 1 Siemens 1 Polarion 2019-12-05 3.5 LOW 5.4 MEDIUM
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13934 1 Siemens 1 Polarion 2019-12-05 3.5 LOW 5.4 MEDIUM
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.
CVE-2019-13920 1 Siemens 1 Sinema Remote Connect Server 2019-10-09 4.3 MEDIUM 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-4835 1 Siemens 1 Telecontrol Server Basic 2019-10-09 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.
CVE-2018-5380 4 Canonical, Debian, Quagga and 1 more 5 Ubuntu Linux, Debian Linux, Quagga and 2 more 2019-10-09 4.0 MEDIUM 4.3 MEDIUM
The Quagga BGP daemon (bgpd) prior to version 1.2.3 can overrun internal BGP code-to-string conversion tables used for debug by 1 pointer value, based on input.
CVE-2018-4861 1 Siemens 2 Scalance M875, Scalance M875 Firmware 2019-10-09 4.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could potentially read and download arbitrary files from the device's file system. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-4839 1 Siemens 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more 2019-10-09 3.5 LOW 5.3 MEDIUM
A vulnerability has been identified in Siemens DIGSI 4 (All versions < V4.92), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77), SIPROTEC Compact 7SJ66 (All versions < V4.30), Other SIPROTEC Compact relays (All versions), Other SIPROTEC 4 relays (All versions). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
CVE-2018-4856 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2019-10-09 4.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.
CVE-2018-4855 1 Siemens 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more 2019-10-09 4.3 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords.
CVE-2018-4844 1 Siemens 1 Simatic Wincc Oa Ui 2019-10-09 3.8 LOW 6.7 MEDIUM
A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
CVE-2018-16555 1 Siemens 8 Scalance S602, Scalance S602 Firmware, Scalance S612 and 5 more 2019-10-09 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.
CVE-2018-13811 1 Siemens 1 Simatic Step 7 \(tia Portal\) 2019-10-09 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.
CVE-2018-11461 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2019-10-09 4.6 MEDIUM 6.6 MEDIUM
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11450 1 Siemens 1 Teamcenter Product Lifecycle Management 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
A reflected Cross-Site-Scripting (XSS) vulnerability has been identified in Siemens PLM Software TEAMCENTER (V9.1.2.5). If a user visits the login portal through the URL crafted by the attacker, the attacker can insert html/javascript and thus alter/rewrite the login portal page. Siemens PLM Software TEAMCENTER V9.1.3 and newer are not affected.
CVE-2018-11456 1 Siemens 1 Automation License Manager 2019-10-09 5.0 MEDIUM 5.8 MEDIUM
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
CVE-2018-11448 1 Siemens 2 Scalance M875, Scalance M875 Firmware 2019-10-09 3.5 LOW 4.8 MEDIUM
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2017-6871 1 Siemens 2 Simatic Wincc Sm\@rtclient, Simatic Wincc Sm\@rtclient Lite 2019-10-09 4.6 MEDIUM 5.4 MEDIUM
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions.
CVE-2017-6872 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2019-10-09 6.4 MEDIUM 6.5 MEDIUM
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device.
CVE-2017-6866 1 Siemens 1 Xhq Server 2019-10-09 4.0 MEDIUM 6.5 MEDIUM
A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.
CVE-2017-12740 1 Siemens 1 Logo\! Soft Comfort 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
Siemens LOGO! Soft Comfort (All versions before V8.2) lacks integrity verification of software packages downloaded via an unprotected communication channel. This could allow a remote attacker to manipulate the software package while performing a Man-in-the-Middle (MitM) attack.
CVE-2017-13099 3 Arubanetworks, Siemens, Wolfssl 4 Instant, Scalance W1750d, Scalance W1750d Firmware and 1 more 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
wolfSSL prior to version 3.12.2 provides a weak Bleichenbacher oracle when any TLS cipher suite using RSA key exchange is negotiated. An attacker can recover the private key from a vulnerable wolfSSL application. This vulnerability is referred to as "ROBOT."
CVE-2018-4847 1 Siemens 1 Simatic Wincc Oa Operator 2019-10-03 2.1 LOW 4.6 MEDIUM
A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app's directory. Siemens provides mitigations to resolve the security issue.
CVE-2018-16563 1 Siemens 34 6md85, 6md86, 7ke85 and 31 more 2019-10-03 4.3 MEDIUM 5.9 MEDIUM
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-10933 1 Siemens 4 Spectrum Power 3, Spectrum Power 4, Spectrum Power 5 and 1 more 2019-08-13 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions < v5.50), Spectrum Power 7 (Corporate User Interface) (All versions <= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known.
CVE-2018-13810 1 Siemens 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more 2019-07-11 4.3 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affected CP devices could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. At the time of advisory publication no public exploitation of this vulnerability was known.
CVE-2018-13809 1 Siemens 4 Cp 1604, Cp 1604 Firmware, Cp 1616 and 1 more 2019-07-11 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into following a malicious link. User interaction is required for a successful exploitation. At the time of advisory publication no public exploitation of this vulnerability was known.
CVE-2019-6577 1 Siemens 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more 2019-05-22 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
CVE-2018-7064 2 Arubanetworks, Siemens 3 Aruba Instant, Scalance W1750d, Scalance W1750d Firmware 2019-05-21 4.3 MEDIUM 6.1 MEDIUM
A reflected cross-site scripting (XSS) vulnerability is present in an unauthenticated Aruba Instant web interface. An attacker could use this vulnerability to trick an IAP administrator into clicking a link which could then take administrative actions on the Instant cluster, or expose the session cookie for an administrative session. Workaround: Administrators should make sure they log out of the Aruba Instant UI when not actively managing the system, and should use caution clicking links from external sources while logged into the IAP administrative interface. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.0