Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-44010 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-12-15 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll is vulnerable to an out of bounds read past the end of an allocated buffer when parsing TIFF files. An attacker could leverage this vulnerability to leak information in the context of the current process.
CVE-2020-28397 1 Siemens 111 Cpu1510sp F-1, Cpu1510sp F-1 Firmware, Cpu 1211c and 108 more 2021-12-10 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
CVE-2020-26146 3 Arista, Samsung, Siemens 38 C-100, C-100 Firmware, C-110 and 35 more 2021-12-06 2.9 LOW 5.3 MEDIUM
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design.
CVE-2020-26144 3 Arista, Samsung, Siemens 36 C-100, C-100 Firmware, C-110 and 33 more 2021-12-04 3.3 LOW 6.5 MEDIUM
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject arbitrary network packets independent of the network configuration.
CVE-2020-26143 3 Alfa, Arista, Siemens 12 Awus036h, Awus036h Firmware, C-65 and 9 more 2021-12-03 3.3 LOW 6.5 MEDIUM
An issue was discovered in the ALFA Windows 10 driver 1030.36.604 for AWUS036ACH. The WEP, WPA, WPA2, and WPA3 implementations accept fragmented plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.
CVE-2021-37731 2 Arubanetworks, Siemens 17 7005, 7008, 7010 and 14 more 2021-11-26 7.2 HIGH 6.2 MEDIUM
A local path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.0-2.2.0.4; Prior to 8.7.1.1, 8.6.0.7, 8.5.0.12, 8.3.0.16. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
CVE-2021-37729 2 Arubanetworks, Siemens 4 Arubaos, Sd-wan, Scalance W1750d and 1 more 2021-11-26 5.5 MEDIUM 6.5 MEDIUM
A remote path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.0-2.2.0.4; Prior to 8.7.1.3, 8.6.0.9, 8.5.0.12, 8.3.0.16, 6.5.4.19, 6.4.4.25. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
CVE-2021-37733 2 Arubanetworks, Siemens 4 Arubaos, Sd-wan, Scalance W1750d and 1 more 2021-11-26 4.0 MEDIUM 4.9 MEDIUM
A remote path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.1, 8.6.0.7, 8.5.0.11, 8.3.0.16. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
CVE-2021-37735 2 Arubanetworks, Siemens 3 Aruba Instant, Scalance W1750d, Scalance W1750d Firmware 2021-11-24 5.0 MEDIUM 5.3 MEDIUM
A remote denial of service vulnerability was discovered in Aruba Instant version(s): Aruba Instant 6.5.x.x: 6.5.4.18 and below; Aruba Instant 8.5.x.x: 8.5.0.10 and below; Aruba Instant 8.6.x.x: 8.6.0.4 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.
CVE-2017-5753 13 Arm, Canonical, Debian and 10 more 387 Cortex-a12, Cortex-a12 Firmware, Cortex-a15 and 384 more 2021-11-23 4.7 MEDIUM 5.6 MEDIUM
Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.
CVE-2020-15794 1 Siemens 1 Desigo Insight 2021-11-18 4.0 MEDIUM 4.3 MEDIUM
A vulnerability has been identified in Desigo Insight (All versions). Some error messages in the web application show the absolute path to the requested resource. This could allow an authenticated attacker to retrieve additional information about the host system.
CVE-2020-7580 1 Siemens 18 Simatic Automatic Tool, Simatic Net Pc, Simatic Pcs 7 and 15 more 2021-11-17 7.2 HIGH 6.7 MEDIUM
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (All versions < V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A component within the affected application regularly calls a helper binary with SYSTEM privileges while the call path is not quoted.
CVE-2017-14023 1 Siemens 2 Simatic Pcs7, Simatic Wincc 2021-11-15 4.0 MEDIUM 4.9 MEDIUM
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface.
CVE-2020-10052 1 Siemens 1 Simatic Rtls Locating Manager 2021-11-11 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as usernames and passwords in log files. A local attacker with access to the log files could use this information to launch further attacks.
CVE-2020-10053 1 Siemens 1 Simatic Rtls Locating Manager 2021-11-11 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.
CVE-2020-10054 1 Siemens 1 Simatic Rtls Locating Manager 2021-11-11 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the application service.
CVE-2019-19277 1 Siemens 1 Siport Mp 2021-11-03 5.5 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SIPORT MP (All versions < 3.1.4). Vulnerable versions of the device allow the creation of special accounts ("service users") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area.
CVE-2019-19278 1 Siemens 2 Sinamics Perfect Harmony Gh180, Sinamics Perfect Harmony Gh180 Firmware 2021-11-03 7.2 HIGH 6.8 MEDIUM
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR32..-.....-.... MLFB 6SR4...-.....-.... MLFB 6SR5...-.....-.... With option A30 (HMIs 12 inches or larger) (All versions), SINAMICS PERFECT HARMONY GH180 Drives MLFB 6SR325.-.....-.... (High Availability) (All versions). The affected device contains a vulnerability that could allow an unauthenticated attacker to restore the affected device to a point where predefined application and operating system protection mechanisms are not in place. Successful exploitation requires physical access to the system, but no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentialiy, integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13919 1 Siemens 1 Sinema Remote Connect Server 2021-11-02 4.0 MEDIUM 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-10917 1 Siemens 4 Simatic Pcs 7, Simatic Wincc, Simatic Wincc \(tia Portal\) and 1 more 2021-11-02 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-19285 1 Siemens 1 Xhq 2021-10-29 3.5 LOW 5.4 MEDIUM
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow injections that could lead to XSS attacks if unsuspecting users are tricked into accessing a malicious link.
CVE-2019-10927 1 Siemens 10 Scalance Xb-200, Scalance Xb-200 Firmware, Scalance Xc-200 and 7 more 2021-10-28 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device.
CVE-2021-33727 1 Siemens 1 Sinec Nms 2021-10-18 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker could download the user profile of any user. With this, the attacker could leak confidential information of any user in the affected system.
CVE-2021-33723 1 Siemens 1 Sinec Nms 2021-10-18 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker could change the user profile of any user without proper authorization. With this, the attacker could change the password of any user in the affected system.
CVE-2021-33722 1 Siemens 1 Sinec Nms 2021-10-18 4.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system.
CVE-2021-40357 1 Siemens 1 Teamcenter Active Workspace 2021-09-28 4.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.10), Teamcenter Active Workspace V5.0 (All versions < V5.0.8), Teamcenter Active Workspace V5.1 (All versions < V5.1.5), Teamcenter Active Workspace V5.2 (All versions < V5.2.1). A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host.
CVE-2021-37190 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve VPN connection for a known user.
CVE-2021-37183 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software allows sending send-to-sleep notifications to the managed devices. An unauthenticated attacker in the same network of the affected system can abuse these notifications to cause a Denial-of-Service condition in the managed devices.
CVE-2021-37193 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). An unauthenticated attacker in the same network of the affected system could manipulate certain parameters and set a valid user of the affected software as invalid (or vice-versa).
CVE-2021-37191 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). An unauthenticated attacker in the same network of the affected system could brute force the usernames from the affected software.
CVE-2021-37177 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system.
CVE-2021-37192 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve a list of network devices a known user can manage.
CVE-2021-37175 1 Siemens 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more 2021-09-23 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices.
CVE-2019-10941 1 Siemens 1 Sinema Server 2021-09-23 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.
CVE-2021-37178 1 Siemens 2 Solid Edge Se2021, Solid Edge Se2021 Firmware 2021-08-20 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). An XML external entity injection vulnerability in the underlying XML parser could cause the affected application to disclose arbitrary files to remote attackers by loading a specially crafted xml file.
CVE-2021-33717 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-08-18 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2.0.1), Teamcenter Visualization (All versions < V13.2.0.1). When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the application to crash. The application must be restarted to restore the service. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
CVE-2017-5715 7 Arm, Canonical, Debian and 4 more 221 Cortex-a, Ubuntu Linux, Debian Linux and 218 more 2021-08-16 1.9 LOW 5.6 MEDIUM
Systems with microprocessors utilizing speculative execution and indirect branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.
CVE-2018-3639 12 Arm, Canonical, Debian and 9 more 321 Cortex-a, Ubuntu Linux, Debian Linux and 318 more 2021-08-13 2.1 LOW 5.5 MEDIUM
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4.
CVE-2021-25671 1 Siemens 6 Rwg1.m12, Rwg1.m12 Firmware, Rwg1.m12d and 3 more 2021-08-04 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in RWG1.M12 (All versions < V1.16.16), RWG1.M12D (All versions < V1.16.16), RWG1.M8 (All versions < V1.16.16). Sending specially crafted ARP packets to an affected device could cause a partial denial-of-service, preventing the device to operate normally. A restart is needed to restore normal operations.
CVE-2021-34322 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The JPEG2K_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13416)
CVE-2021-34320 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13406)
CVE-2021-34325 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13421)
CVE-2021-34299 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13192)
CVE-2021-34304 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13199)
CVE-2021-34303 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)
CVE-2021-34307 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13343)
CVE-2021-34308 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13344)
CVE-2021-34302 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13197)
CVE-2021-34321 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-07-27 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The VisDraw.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13414)
CVE-2021-33718 1 Siemens 1 Mendix 2021-07-27 3.5 LOW 5.3 MEDIUM
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.22), Mendix Applications using Mendix 8 (All versions < V8.18.7), Mendix Applications using Mendix 9 (All versions < V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object.