Vulnerabilities (CVE)

Filtered by CWE-754
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-41992 1 Apple 3 Ipados, Iphone Os, Macos 2024-01-10 N/A 7.8 HIGH
The issue was addressed with improved checks. This issue is fixed in macOS Monterey 12.7, iOS 16.7 and iPadOS 16.7, macOS Ventura 13.6. A local attacker may be able to elevate their privileges. Apple is aware of a report that this issue may have been actively exploited against versions of iOS before iOS 16.7.
CVE-2023-49286 1 Squid-cache 1 Squid 2024-01-09 N/A 7.5 HIGH
Squid is a caching proxy for the Web supporting HTTP, HTTPS, FTP, and more. Due to an Incorrect Check of Function Return Value bug Squid is vulnerable to a Denial of Service attack against its Helper process management. This bug is fixed by Squid version 6.5. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2023-32726 1 Zabbix 1 Zabbix-agent 2023-12-22 N/A 8.1 HIGH
The vulnerability is caused by improper check for check if RDLENGTH does not overflow the buffer in response from DNS server.
CVE-2023-48431 1 Siemens 1 Sinec Ins 2023-12-14 N/A 8.6 HIGH
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).
CVE-2023-49607 1 Mattermost 1 Mattermost Server 2023-12-14 N/A 7.5 HIGH
Mattermost fails to validate the type of the "reminder" body request parameter allowing an attacker to crash the Playbook Plugin when updating the status dialog.
CVE-2021-42020 1 Siemens 54 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 51 more 2023-12-12 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. The third-party component, in its TFTP functionality fails to check for null terminations in file names. If an attacker were to exploit this, it could result in data corruption, and possibly a hard-fault of the application.
CVE-2023-44099 1 Huawei 2 Emui, Harmonyos 2023-12-11 N/A 7.5 HIGH
Vulnerability of data verification errors in the kernel module. Successful exploitation of this vulnerability may cause WLAN interruption.
CVE-2022-25024 1 Vinitkumar 1 Json2xml 2023-08-25 N/A 7.5 HIGH
The json2xml package through 3.12.0 for Python allows an error in typecode decoding enabling a remote attack that can lead to an exception, causing a denial of service.
CVE-2023-37899 1 Feathersjs 1 Feathers 2023-07-28 N/A 7.5 HIGH
Feathersjs is a framework for creating web APIs and real-time applications with TypeScript or JavaScript. Feathers socket handler did not catch invalid string conversion errors like `const message = ${{ toString: '' }}` which would cause the NodeJS process to crash when sending an unexpected Socket.io message like `socket.emit('find', { toString: '' })`. A fix has been released in versions 5.0.8 and 4.5.18. Users are advised to upgrade. There is no known workaround for this vulnerability.
CVE-2023-36835 1 Juniper 5 Junos, Qfx10002, Qfx10002-60c and 2 more 2023-07-27 N/A 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on QFX10000 Series allows a network based attacker to cause a Denial of Service (DoS). If a specific valid IP packet is received and that packet needs to be routed over a VXLAN tunnel, this will result in a PFE wedge condition due to which traffic gets impacted. As this is not a crash and restart scenario, this condition will persist until the system is rebooted to recover. This issue affects Juniper Networks Junos OS on QFX10000: 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3-S5; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S5; 21.3 versions prior to 21.3R3-S4; 21.4 versions prior to 21.4R3-S1; 22.1 versions prior to 22.1R3; 22.2 versions prior to 22.2R2; 22.3 versions prior to 22.3R1-S2, 22.3R2.
CVE-2021-38599 1 Wal-g Project 1 Wal-g 2022-07-12 5.0 MEDIUM 7.5 HIGH
WAL-G before 1.1, when a non-libsodium build (e.g., one of the official binary releases published as GitHub Releases) is used, silently ignores the libsodium encryption key and uploads cleartext backups. This is arguably a Principle of Least Surprise violation because "the user likely wanted to encrypt all file activity."
CVE-2021-3560 4 Canonical, Debian, Polkit Project and 1 more 7 Ubuntu Linux, Debian Linux, Polkit and 4 more 2022-07-11 7.2 HIGH 7.8 HIGH
It was found that polkit could be tricked into bypassing the credential checks for D-Bus requests, elevating the privileges of the requestor to the root user. This flaw could be used by an unprivileged local attacker to, for example, create a new local administrator. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.
CVE-2022-31093 1 Nextauth.js 1 Next-auth 2022-07-07 5.0 MEDIUM 7.5 HIGH
NextAuth.js is a complete open source authentication solution for Next.js applications. In affected versions an attacker can send a request to an app using NextAuth.js with an invalid `callbackUrl` query parameter, which internally is converted to a `URL` object. The URL instantiation would fail due to a malformed URL being passed into the constructor, causing it to throw an unhandled error which led to the **API route handler timing out and logging in to fail**. This has been remedied in versions 3.29.5 and 4.5.0. If for some reason you cannot upgrade, the workaround requires you to rely on Advanced Initialization. Please see the documentation for more.
CVE-2022-31103 1 Lettersanitizer Project 1 Lettersanitizer 2022-07-06 5.0 MEDIUM 7.5 HIGH
lettersanitizer is a DOM-based HTML email sanitizer for in-browser email rendering. All versions of lettersanitizer below 1.0.2 are affected by a denial of service issue when processing a CSS at-rule `@keyframes`. This package is depended on by [react-letter](https://github.com/mat-sz/react-letter), therefore everyone using react-letter is also at risk. The problem has been patched in version 1.0.2.
CVE-2021-32780 1 Envoyproxy 1 Envoy 2022-06-15 5.0 MEDIUM 7.5 HIGH
Envoy is an open source L7 proxy and communication bus designed for large modern service oriented architectures. In affected versions Envoy transitions a H/2 connection to the CLOSED state when it receives a GOAWAY frame without any streams outstanding. The connection state is transitioned to DRAINING when it receives a SETTING frame with the SETTINGS_MAX_CONCURRENT_STREAMS parameter set to 0. Receiving these two frames in the same I/O event results in abnormal termination of the Envoy process due to invalid state transition from CLOSED to DRAINING. A sequence of H/2 frames delivered by an untrusted upstream server will result in Denial of Service in the presence of untrusted **upstream** servers. Envoy versions 1.19.1, 1.18.4 contain fixes to stop processing of pending H/2 frames after connection transition to the CLOSED state.
CVE-2022-21676 1 Socket 1 Engine.io 2022-06-14 5.0 MEDIUM 7.5 HIGH
Engine.IO is the implementation of transport-based cross-browser/cross-device bi-directional communication layer for Socket.IO. A specially crafted HTTP request can trigger an uncaught exception on the Engine.IO server, thus killing the Node.js process. This impacts all the users of the `engine.io` package starting from version `4.0.0`, including those who uses depending packages like `socket.io`. Versions prior to `4.0.0` are not impacted. A fix has been released for each major branch, namely `4.1.2` for the `4.x.x` branch, `5.2.1` for the `5.x.x` branch, and `6.1.1` for the `6.x.x` branch. There is no known workaround except upgrading to a safe version.
CVE-2018-4026 1 Anker-in 2 Roav Dashcam A1, Roav Dashcam A1 Firmware 2022-06-07 7.8 HIGH 7.5 HIGH
An exploitable denial-of-service vulnerability exists in the XML_GetScreen Wi-Fi command of the NT9665X Chipset firmware, running on the Anker Roav A1 Dashcam, version RoavA1SWV1.9. A specially crafted set of packets can cause an invalid memory dereference, resulting in a device reboot.
CVE-2022-29369 1 F5 1 Njs 2022-05-23 5.0 MEDIUM 7.5 HIGH
Nginx NJS v0.7.2 was discovered to contain a segmentation violation via njs_lvlhsh_bucket_find at njs_lvlhsh.c.
CVE-2022-29473 1 F5 11 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 8 more 2022-05-12 5.0 MEDIUM 7.5 HIGH
On F5 BIG-IP 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, and 13.1.x versions prior to 13.1.5, when an IPSec ALG profile is configured on a virtual server, undisclosed responses can cause Traffic Management Microkernel(TMM) to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CVE-2022-28706 1 F5 11 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 8 more 2022-05-12 5.0 MEDIUM 7.5 HIGH
On F5 BIG-IP 16.1.x versions prior to 16.1.2 and 15.1.x versions prior to 15.1.5.1, when the DNS resolver configuration is used, undisclosed requests can cause the Traffic Management Microkernel (TMM) to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CVE-2019-1010239 2 Cjson Project, Oracle 2 Cjson, Timesten In-memory Database 2022-05-03 5.0 MEDIUM 7.5 HIGH
DaveGamble/cJSON cJSON 1.7.8 is affected by: Improper Check for Unusual or Exceptional Conditions. The impact is: Null dereference, so attack can cause denial of service. The component is: cJSON_GetObjectItemCaseSensitive() function. The attack vector is: crafted json file. The fixed version is: 1.7.9 and later.
CVE-2022-23590 1 Google 1 Tensorflow 2022-02-17 5.0 MEDIUM 7.5 HIGH
Tensorflow is an Open Source Machine Learning Framework. A `GraphDef` from a TensorFlow `SavedModel` can be maliciously altered to cause a TensorFlow process to crash due to encountering a `StatusOr` value that is an error and forcibly extracting the value from it. We have patched the issue in multiple GitHub commits and these will be included in TensorFlow 2.8.0 and TensorFlow 2.7.1, as both are affected.
CVE-2022-24321 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2022-02-16 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-23593 1 Google 1 Tensorflow 2022-02-10 5.0 MEDIUM 7.5 HIGH
Tensorflow is an Open Source Machine Learning Framework. The `simplifyBroadcast` function in the MLIR-TFRT infrastructure in TensorFlow is vulnerable to a segfault (hence, denial of service), if called with scalar shapes. If all shapes are scalar, then `maxRank` is 0, so we build an empty `SmallVector`. The fix will be included in TensorFlow 2.8.0. This is the only affected version.
CVE-2019-6857 1 Schneider-electric 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
CVE-2019-6856 1 Schneider-electric 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
CVE-2018-7794 1 Schneider-electric 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
CVE-2018-7789 1 Schneider-electric 2 Modicon M221, Modicon M221 Firmware 2022-02-03 7.8 HIGH 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames.
CVE-2019-6813 1 Schneider-electric 4 Bmxnor0200h, Bmxnor0200h Firmware, Modicon M340 and 1 more 2022-02-03 7.8 HIGH 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.
CVE-2018-7856 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus.
CVE-2018-7857 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus.
CVE-2018-7855 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus
CVE-2018-7853 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus
CVE-2018-7854 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2022-02-03 5.0 MEDIUM 7.5 HIGH
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus.
CVE-2021-22816 1 Schneider-electric 18 Scadapack 312e, Scadapack 312e Firmware, Scadapack 313e and 15 more 2022-02-03 7.8 HIGH 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior
CVE-2022-22180 1 Juniper 11 Ex2300, Ex2300-24mp, Ex2300-24p and 8 more 2022-02-01 5.0 MEDIUM 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions vulnerability in the processing of specific IPv6 packets on certain EX Series devices may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this vulnerability may cause traffic to stop being forwarded, or a crash of the fxpc process. An indication of the issue occurring may be observed through the following log messages: Sep 13 17:14:59 hostname : %PFE-3: fpc0 (buf alloc) failed allocating packet buffer Sep 13 17:14:59 hostname : %PFE-7: fpc0 brcm_pkt_buf_alloc:393 (buf alloc) failed allocating packet buffer When Packet DMA heap utilization reaches 99%, the system will become unstable. Packet DMA heap utilization can be monitored using the command: user@junos# request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name -- ---------- ----------- ----------- ----------- --- ----------- 0 213301a8 536870488 387228840 149641648 27 Kernel 1 91800000 8388608 3735120 4653488 55 DMA 2 92000000 75497472 74452192 1045280 1 PKT DMA DESC 3 d330000 335544320 257091400 78452920 23 Bcm_sdk 4 96800000 184549376 2408 184546968 99 Packet DMA <<<< 5 903fffe0 20971504 20971504 0 0 Blob This issue affects: Juniper Networks Junos OS 18.4 versions prior to 18.4R2-S10, 18.4R3-S10 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.1 versions prior to 19.1R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.3 versions prior to 19.3R3-S5 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.4 versions prior to 19.4R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.1 versions prior to 20.1R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.2 versions prior to 20.2R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.3 versions prior to 20.3R3-S2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.4 versions prior to 20.4R3-S1 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.1 versions prior to 21.1R2-S2, 21.1R3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.2 versions prior to 21.2R1-S2, 21.2R2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.3 versions prior to 21.3R1-S1, 21.3R2 on EX2300 Series, EX2300-MP Series, EX3400 Series.
CVE-2020-7538 1 Schneider-electric 1 Ecostruxure Control Expert 2022-01-31 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
CVE-2022-22171 1 Juniper 1 Junos 2022-01-26 5.0 MEDIUM 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an unauthenticated networked attacker to cause a Denial of Service (DoS) by sending specific packets over VXLAN which cause the PFE to reset. This issue affects: Juniper Networks Junos OS 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2. This issue does not affect versions of Junos OS prior to 19.4R1.
CVE-2021-43801 1 Mercurius Project 1 Mercurius 2021-12-15 5.0 MEDIUM 7.5 HIGH
Mercurius is a GraphQL adapter for Fastify. Any users from Mercurius@8.10.0 to 8.11.1 are subjected to a denial of service attack by sending a malformed JSON to `/graphql` unless they are using a custom error handler. The vulnerability has been fixed in https://github.com/mercurius-js/mercurius/pull/678 and shipped as v8.11.2. As a workaround users may use a custom error handler.
CVE-2021-22447 1 Huawei 2 Emui, Magic Ui 2021-12-09 7.8 HIGH 7.5 HIGH
There is an Improper Check for Unusual or Exceptional Conditions Vulnerability in Huawei Smartphone.Successful exploitation of this vulnerability may cause the system to reset.
CVE-2021-0002 2 Fedoraproject, Intel 3 Fedora, Ethernet Controller E810, Ethernet Controller E810 Firmware 2021-11-30 3.6 LOW 7.1 HIGH
Improper conditions check in some Intel(R) Ethernet Controllers 800 series Linux drivers before version 1.4.11 may allow an authenticated user to potentially enable information disclosure or denial of service via local access.
CVE-2021-31351 1 Juniper 18 Junos, Mx10, Mx10000 and 15 more 2021-10-25 5.0 MEDIUM 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions in packet processing on the MS-MPC/MS-MIC utilized by Juniper Networks Junos OS allows a malicious attacker to send a specific packet, triggering the MS-MPC/MS-MIC to reset, causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects specific versions of Juniper Networks Junos OS on MX Series: 17.3R3-S11; 17.4R2-S13; 17.4R3 prior to 17.4R3-S5; 18.1R3-S12; 18.2R2-S8, 18.2R3-S7, 18.2R3-S8; 18.3R3-S4; 18.4R3-S7; 19.1R3-S4, 19.1R3-S5; 19.2R1-S6; 19.3R3-S2; 19.4R2-S4, 19.4R2-S5; 19.4R3-S2; 20.1R2-S1; 20.2R2-S2, 20.2R2-S3, 20.2R3; 20.3R2, 20.3R2-S1; 20.4R1, 20.4R1-S1, 20.4R2; 21.1R1; This issue does not affect any version of Juniper Networks Junos OS prior to 15.1X49-D240;
CVE-2021-0286 1 Juniper 1 Junos Os Evolved 2021-10-25 7.8 HIGH 7.5 HIGH
A vulnerability in the handling of exceptional conditions in Juniper Networks Junos OS Evolved (EVO) allows an attacker to send specially crafted packets to the device, causing the Advanced Forwarding Toolkit manager (evo-aftmand-bt or evo-aftmand-zx) process to crash and restart, impacting all traffic going through the FPC, resulting in a Denial of Service (DoS). Continued receipt and processing of these packets will create a sustained Denial of Service (DoS) condition. Following messages will be logged prior to the crash: Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:32710470974358 label:1089551617 for session:18 probe:35 Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:19241453497049 label:1089551617 for session:18 probe:37 Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:19241453497049 label:1089551617 for session:18 probe:44 Feb 2 10:14:39 fpc0 evo-aftmand-bt[16263]: [Error] Nexthop: Failed to get fwd nexthop for nexthop:32710470974358 label:1089551617 for session:18 probe:47 Feb 2 10:14:39 fpc0 audit[16263]: ANOM_ABEND auid=4294967295 uid=0 gid=0 ses=4294967295 pid=16263 comm="EvoAftManBt-mai" exe="/usr/sbin/evo-aftmand-bt" sig=11 Feb 2 10:14:39 fpc0 kernel: audit: type=1701 audit(1612260879.272:17): auid=4294967295 uid=0 gid=0 ses=4294967295 pid=16263 comm="EvoAftManBt-mai" exe="/usr/sbin/evo-aftmand-bt" sig=1 This issue affects Juniper Networks Junos OS Evolved: All versions prior to 20.4R2-EVO; 21.1 versions prior to 21.1R2-EVO.
CVE-2020-24677 1 Abb 2 Symphony \+ Historian, Symphony \+ Operations 2021-10-07 6.5 MEDIUM 8.8 HIGH
Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirect the user somewhere else or download unwanted data.
CVE-2021-39162 2 Envoyproxy, Pomerium 2 Envoy, Pomerium 2021-09-27 5.0 MEDIUM 8.6 HIGH
Pomerium is an open source identity-aware access proxy. Envoy, which Pomerium is based on, can abnormally terminate if an H/2 GOAWAY and SETTINGS frame are received in the same IO event. This can lead to a DoS in the presence of untrusted *upstream* servers. 0.15.1 contains an upgraded envoy binary with this vulnerability patched. If only trusted upstreams are configured, there is not substantial risk of this condition being triggered.
CVE-2021-32946 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 6.8 MEDIUM 7.8 HIGH
An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
CVE-2020-19766 1 Tokenerc20 Project 1 Tokenerc20 2021-09-15 5.0 MEDIUM 7.5 HIGH
The time check operation of PepeAuctionSale 1.0 can be rendered ineffective by assigning a large number to the _duration variable, compromising access control to the application.
CVE-2021-40523 1 Contiki-os 1 Contiki 2021-09-10 5.0 MEDIUM 7.5 HIGH
In Contiki 3.0, Telnet option negotiation is mishandled. During negotiation between a server and a client, the server may fail to give the WILL/WONT or DO/DONT response for DO and WILL commands because of improper handling of exception condition, which leads to property violations and denial of service. Specifically, a server sometimes sends no response, because a fixed buffer space is available for all responses and that space may have been exhausted.
CVE-2020-35931 3 Apple, Foxitsoftware, Microsoft 4 Macos, Foxit Reader, Phantompdf and 1 more 2021-09-08 6.8 MEDIUM 7.8 HIGH
An issue was discovered in Foxit Reader before 10.1.1 (and before 4.1.1 on macOS) and PhantomPDF before 9.7.5 and 10.x before 10.1.1 (and before 4.1.1 on macOS). An attacker can spoof a certified PDF document via an Evil Annotation Attack because the products fail to consider a null value for a Subtype entry of the Annotation dictionary, in an incremental update.
CVE-2019-6819 1 Schneider-electric 38 Bmeh582040, Bmeh582040c, Bmeh584040 and 35 more 2021-08-18 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium.