| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-49251 | 1 Siemens | 1 Simatic Cn 4100 | 2024-01-12 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up. | |||||
| CVE-2023-49621 | 1 Siemens | 1 Simatic Cn 4100 | 2024-01-11 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device. | |||||
| CVE-2019-18342 | 1 Siemens | 1 Control Center Server | 2024-01-09 | 7.5 HIGH | 9.9 CRITICAL |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) does not properly limit its capabilities to the specified purpose. In conjunction with CVE-2019-18341, an unauthenticated remote attacker with network access to the CCS server could exploit this vulnerability to read or delete arbitrary files, or access other resources on the same server. | |||||
| CVE-2019-18339 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. A remote attacker with network access to the Video Server could exploit this vulnerability to read the SiVMS/SiNVR users database, including the passwords of all users in obfuscated cleartext. | |||||
| CVE-2019-18337 | 1 Siemens | 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server | 2024-01-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext. | |||||
| CVE-2021-22930 | 4 Debian, Netapp, Nodejs and 1 more | 4 Debian Linux, Nextgen Api, Node.js and 1 more | 2024-01-05 | 7.5 HIGH | 9.8 CRITICAL |
| Node.js before 16.6.0, 14.17.4, and 12.22.4 is vulnerable to a use after free attack where an attacker might be able to exploit the memory corruption, to change process behavior. | |||||
| CVE-2021-22931 | 4 Netapp, Nodejs, Oracle and 1 more | 10 Active Iq Unified Manager, Nextgen Api, Oncommand Insight and 7 more | 2024-01-05 | 7.5 HIGH | 9.8 CRITICAL |
| Node.js before 16.6.0, 14.17.4, and 12.22.4 is vulnerable to Remote Code Execution, XSS, Application crashes due to missing input validation of host names returned by Domain Name Servers in Node.js dns library which can lead to output of wrong hostnames (leading to Domain Hijacking) and injection vulnerabilities in applications using the library. | |||||
| CVE-2023-48427 | 1 Siemens | 1 Sinec Ins | 2023-12-14 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected products do not properly validate the certificate of the configured UMC server. This could allow an attacker to intercept credentials that are sent to the UMC server as well as to manipulate responses, potentially allowing an attacker to escalate privileges. | |||||
| CVE-2023-44373 | 1 Siemens | 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more | 2023-12-12 | N/A | 9.1 CRITICAL |
| A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU, RUGGEDCOM RM1224 LTE(4G) NAM, SCALANCE M804PB, SCALANCE M812-1 ADSL-Router (Annex A), SCALANCE M812-1 ADSL-Router (Annex B), SCALANCE M816-1 ADSL-Router (Annex A), SCALANCE M816-1 ADSL-Router (Annex B), SCALANCE M826-2 SHDSL-Router, SCALANCE M874-2, SCALANCE M874-3, SCALANCE M876-3 (EVDO), SCALANCE M876-3 (ROK), SCALANCE M876-4, SCALANCE M876-4 (EU), SCALANCE M876-4 (NAM), SCALANCE MUM853-1 (EU), SCALANCE MUM856-1 (EU), SCALANCE MUM856-1 (RoW), SCALANCE S615, SCALANCE S615 EEC, SCALANCE XB205-3 (SC, PN), SCALANCE XB205-3 (ST, E/IP), SCALANCE XB205-3 (ST, E/IP), SCALANCE XB205-3 (ST, PN), SCALANCE XB205-3LD (SC, E/IP), SCALANCE XB205-3LD (SC, PN), SCALANCE XB208 (E/IP), SCALANCE XB208 (PN), SCALANCE XB213-3 (SC, E/IP), SCALANCE XB213-3 (SC, PN), SCALANCE XB213-3 (ST, E/IP), SCALANCE XB213-3 (ST, PN), SCALANCE XB213-3LD (SC, E/IP), SCALANCE XB213-3LD (SC, PN), SCALANCE XB216 (E/IP), SCALANCE XB216 (PN), SCALANCE XC206-2 (SC), SCALANCE XC206-2 (ST/BFOC), SCALANCE XC206-2G PoE, SCALANCE XC206-2G PoE (54 V DC), SCALANCE XC206-2G PoE EEC (54 V DC), SCALANCE XC206-2SFP, SCALANCE XC206-2SFP EEC, SCALANCE XC206-2SFP G, SCALANCE XC206-2SFP G (EIP DEF.), SCALANCE XC206-2SFP G EEC, SCALANCE XC208, SCALANCE XC208EEC, SCALANCE XC208G, SCALANCE XC208G (EIP def.), SCALANCE XC208G EEC, SCALANCE XC208G PoE, SCALANCE XC208G PoE (54 V DC), SCALANCE XC216, SCALANCE XC216-3G PoE, SCALANCE XC216-3G PoE (54 V DC), SCALANCE XC216-4C, SCALANCE XC216-4C G, SCALANCE XC216-4C G (EIP Def.), SCALANCE XC216-4C G EEC, SCALANCE XC216EEC, SCALANCE XC224, SCALANCE XC224-4C G, SCALANCE XC224-4C G (EIP Def.), SCALANCE XC224-4C G EEC, SCALANCE XF204, SCALANCE XF204 DNA, SCALANCE XF204-2BA, SCALANCE XF204-2BA DNA, SCALANCE XP208, SCALANCE XP208 (Ethernet/IP), SCALANCE XP208EEC, SCALANCE XP208PoE EEC, SCALANCE XP216, SCALANCE XP216 (Ethernet/IP), SCALANCE XP216EEC, SCALANCE XP216POE EEC, SCALANCE XR324WG (24 x FE, AC 230V), SCALANCE XR324WG (24 X FE, DC 24V), SCALANCE XR326-2C PoE WG, SCALANCE XR326-2C PoE WG (without UL), SCALANCE XR328-4C WG (24XFE, 4XGE, 24V), SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V), SCALANCE XR328-4C WG (24xFE,4xGE,AC230V), SCALANCE XR328-4C WG (28xGE, AC 230V), SCALANCE XR328-4C WG (28xGE, DC 24V), SIPLUS NET SCALANCE XC206-2, SIPLUS NET SCALANCE XC206-2SFP, SIPLUS NET SCALANCE XC208, SIPLUS NET SCALANCE XC216-4C. Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323. | |||||
| CVE-2022-36361 | 1 Siemens | 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more | 2023-12-12 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in LOGO! 12/24RCE (All versions), LOGO! 12/24RCEo (All versions), LOGO! 230RCE (All versions), LOGO! 230RCEo (All versions), LOGO! 24CE (All versions), LOGO! 24CEo (All versions), LOGO! 24RCE (All versions), LOGO! 24RCEo (All versions), SIPLUS LOGO! 12/24RCE (All versions), SIPLUS LOGO! 12/24RCEo (All versions), SIPLUS LOGO! 230RCE (All versions), SIPLUS LOGO! 230RCEo (All versions), SIPLUS LOGO! 24CE (All versions), SIPLUS LOGO! 24CEo (All versions), SIPLUS LOGO! 24RCE (All versions), SIPLUS LOGO! 24RCEo (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. | |||||
| CVE-2021-37208 | 1 Siemens | 54 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 51 more | 2023-12-12 | 3.5 LOW | 9.6 CRITICAL |
| A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Improper neutralization of special characters on the web server configuration page could allow an attacker, in a privileged position, to retrieve sensitive information via cross-site scripting. | |||||
| CVE-2023-43504 | 1 Siemens | 1 Comos | 2023-11-18 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in COMOS (All versions < V10.4.4). Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition. | |||||
| CVE-2023-24845 | 1 Siemens | 127 Ruggedcom I800, Ruggedcom I800nc, Ruggedcom I801 and 124 more | 2023-11-14 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. The affected products insufficiently block data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior. | |||||
| CVE-2023-37372 | 1 Siemens | 1 Ruggedcom Crossbow | 2023-08-10 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications is vulnerable to SQL injection. This could allow an unauthenticated remote attackers to execute arbitrary SQL queries on the server database. | |||||
| CVE-2020-25226 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-28 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. | |||||
| CVE-2022-22965 | 5 Cisco, Oracle, Siemens and 2 more | 27 Cx Cloud Agent, Communications Cloud Native Core Automated Test Suite, Communications Cloud Native Core Console and 24 more | 2022-07-25 | 7.5 HIGH | 9.8 CRITICAL |
| A Spring MVC or Spring WebFlux application running on JDK 9+ may be vulnerable to remote code execution (RCE) via data binding. The specific exploit requires the application to run on Tomcat as a WAR deployment. If the application is deployed as a Spring Boot executable jar, i.e. the default, it is not vulnerable to the exploit. However, the nature of the vulnerability is more general, and there may be other ways to exploit it. | |||||
| CVE-2021-45046 | 6 Apache, Debian, Fedoraproject and 3 more | 61 Log4j, Debian Linux, Fedora and 58 more | 2022-07-25 | 5.1 MEDIUM | 9.0 CRITICAL |
| It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default. | |||||
| CVE-2021-44228 | 10 Apache, Bentley, Cisco and 7 more | 155 Log4j, Synchro, Synchro 4d and 152 more | 2022-07-22 | 9.3 HIGH | 10.0 CRITICAL |
| Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects. | |||||
| CVE-2022-34821 | 1 Siemens | 30 Simatic Cp 1242-7 V2, Simatic Cp 1242-7 V2 Firmware, Simatic Cp 1243-1 and 27 more | 2022-07-15 | 9.3 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges. | |||||
| CVE-2022-34820 | 1 Siemens | 30 Simatic Cp 1242-7 V2, Simatic Cp 1242-7 V2 Firmware, Simatic Cp 1243-1 and 27 more | 2022-07-15 | 9.3 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges. | |||||
| CVE-2022-34819 | 1 Siemens | 30 Simatic Cp 1242-7 V2, Simatic Cp 1242-7 V2 Firmware, Simatic Cp 1243-1 and 27 more | 2022-07-15 | 9.3 HIGH | 10.0 CRITICAL |
| A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device. | |||||
| CVE-2021-44222 | 1 Siemens | 1 Simatic Easie Core Package | 2022-07-15 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The underlying MQTT service of affected systems does not perform authentication in the default configuration. This could allow an unauthenticated remote attacker to send arbitrary messages to the service and thereby issue arbitrary requests in the affected system. | |||||
| CVE-2022-26647 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-07-15 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions), SCALANCE X200-4P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions), SCALANCE X204IRT (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions), SCALANCE XF202-2P IRT (All versions), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. | |||||
| CVE-2021-29998 | 2 Siemens, Windriver | 69 Ruggedcom Win Subscriber Station, Ruggedcom Win Subscriber Station Firmware, Scalance X200-4 P Irt and 66 more | 2022-07-12 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client. | |||||
| CVE-2019-6569 | 1 Siemens | 10 Scalance X-200, Scalance X-200 Firmware, Scalance X-300 and 7 more | 2022-07-12 | 6.4 MEDIUM | 9.1 CRITICAL |
| The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior. | |||||
| CVE-2020-15800 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-01 | 9.3 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. | |||||
| CVE-2022-33139 | 1 Siemens | 1 Wincc Open Architecture | 2022-06-29 | 6.8 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC WinCC OA V3.16 (All versions in default configuration), SIMATIC WinCC OA V3.17 (All versions in non-default configuration), SIMATIC WinCC OA V3.18 (All versions in non-default configuration). Affected applications use client-side only authentication, when neither server-side authentication (SSA) nor Kerberos authentication is enabled. In this configuration, attackers could impersonate other users or exploit the client-server protocol without being authenticated. | |||||
| CVE-2022-32260 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-23 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application creates temporary user credentials for UMC (User Management Component) users. An attacker could use these temporary credentials for authentication bypass in certain scenarios. | |||||
| CVE-2022-32262 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-22 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution. | |||||
| CVE-2022-32251 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-06-22 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user. | |||||
| CVE-2022-30230 | 1 Siemens | 1 Sicam Gridedge Essential | 2022-06-22 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions < V2.6.6), SICAM GridEdge Essential Intel (All versions < V2.6.6), SICAM GridEdge Essential with GDS ARM (All versions < V2.6.6), SICAM GridEdge Essential with GDS Intel (All versions < V2.6.6). The affected software does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions. | |||||
| CVE-2019-12262 | 3 Belden, Siemens, Windriver | 42 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 39 more | 2022-06-16 | 7.5 HIGH | 9.8 CRITICAL |
| Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and 7 has Incorrect Access Control in the RARP client component. IPNET security vulnerability: Handling of unsolicited Reverse ARP replies (Logical Flaw). | |||||
| CVE-2019-12261 | 6 Belden, Netapp, Oracle and 3 more | 51 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 48 more | 2022-06-16 | 7.5 HIGH | 9.8 CRITICAL |
| Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host. | |||||
| CVE-2019-12260 | 6 Belden, Netapp, Oracle and 3 more | 51 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 48 more | 2022-06-16 | 7.5 HIGH | 9.8 CRITICAL |
| Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option. | |||||
| CVE-2019-12255 | 5 Belden, Netapp, Siemens and 2 more | 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more | 2022-06-16 | 7.5 HIGH | 9.8 CRITICAL |
| Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow. | |||||
| CVE-2019-12256 | 5 Belden, Netapp, Siemens and 2 more | 50 Garrettcom Magnum Dx940e, Garrettcom Magnum Dx940e Firmware, Hirschmann Dragon Mach4000 and 47 more | 2022-06-16 | 7.5 HIGH | 9.8 CRITICAL |
| Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options. | |||||
| CVE-2020-27304 | 2 Civetweb Project, Siemens | 2 Civetweb, Sinec Infrastructure Network Services | 2022-06-14 | 7.5 HIGH | 9.8 CRITICAL |
| The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal | |||||
| CVE-2021-25149 | 2 Arubanetworks, Siemens | 3 Instant, Scalance W1750d, Scalance W1750d Firmware | 2022-06-04 | 7.5 HIGH | 9.8 CRITICAL |
| A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability. | |||||
| CVE-2022-29873 | 1 Siemens | 72 7kg8500-0aa00-0aa0, 7kg8500-0aa00-0aa0 Firmware, 7kg8500-0aa00-2aa0 and 69 more | 2022-05-26 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not properly validate parameters of certain GET and POST requests. This could allow an unauthenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device. | |||||
| CVE-2022-24039 | 1 Siemens | 4 Desigo Pxc4, Desigo Pxc4 Firmware, Desigo Pxc5 and 1 more | 2022-05-20 | 8.5 HIGH | 9.0 CRITICAL |
| A vulnerability has been identified in Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The “addCell” JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator’s workstation. | |||||
| CVE-2022-24042 | 1 Siemens | 8 Desigo Dxr2, Desigo Dxr2 Firmware, Desigo Pxc3 and 5 more | 2022-05-20 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization. | |||||
| CVE-2021-40358 | 1 Siemens | 2 Simatic Pcs 7, Simatic Wincc | 2022-05-20 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files. | |||||
| CVE-2021-31890 | 1 Siemens | 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more | 2022-05-20 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017) | |||||
| CVE-2021-31345 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2022-05-20 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006) | |||||
| CVE-2021-31884 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2022-05-20 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014) | |||||
| CVE-2021-31886 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2022-05-20 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010) | |||||
| CVE-2021-31346 | 1 Siemens | 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more | 2022-05-20 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007) | |||||
| CVE-2021-31889 | 1 Siemens | 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more | 2022-05-20 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015) | |||||
| CVE-2021-25669 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-05-13 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. | |||||
| CVE-2020-24636 | 2 Arubanetworks, Siemens | 3 Instant, Scalance W1750d, Scalance W1750d Firmware | 2022-05-12 | 10.0 HIGH | 9.8 CRITICAL |
| A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability. | |||||