Filtered by vendor Siemens
Subscribe
Search
Total
145 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-25216 | 4 Debian, Isc, Netapp and 1 more | 23 Debian Linux, Bind, Active Iq Unified Manager and 20 more | 2022-05-03 | 6.8 MEDIUM | 9.8 CRITICAL |
| In BIND 9.5.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.11.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch, BIND servers are vulnerable if they are running an affected version and are configured to use GSS-TSIG features. In a configuration which uses BIND's default settings the vulnerable code path is not exposed, but a server can be rendered vulnerable by explicitly setting values for the tkey-gssapi-keytab or tkey-gssapi-credential configuration options. Although the default configuration is not vulnerable, GSS-TSIG is frequently used in networks where BIND is integrated with Samba, as well as in mixed-server environments that combine BIND servers with Active Directory domain controllers. For servers that meet these conditions, the ISC SPNEGO implementation is vulnerable to various attacks, depending on the CPU architecture for which BIND was built: For named binaries compiled for 64-bit platforms, this flaw can be used to trigger a buffer over-read, leading to a server crash. For named binaries compiled for 32-bit platforms, this flaw can be used to trigger a server crash due to a buffer overflow and possibly also to achieve remote code execution. We have determined that standard SPNEGO implementations are available in the MIT and Heimdal Kerberos libraries, which support a broad range of operating systems, rendering the ISC implementation unnecessary and obsolete. Therefore, to reduce the attack surface for BIND users, we will be removing the ISC SPNEGO implementation in the April releases of BIND 9.11 and 9.16 (it had already been dropped from BIND 9.17). We would not normally remove something from a stable ESV (Extended Support Version) of BIND, but since system libraries can replace the ISC SPNEGO implementation, we have made an exception in this case for reasons of stability and security. | |||||
| CVE-2021-25668 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-05-01 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. | |||||
| CVE-2021-37716 | 2 Arubanetworks, Siemens | 4 Arubaos, Sd-wan, Scalance W1750d and 1 more | 2022-02-24 | 10.0 HIGH | 9.8 CRITICAL |
| A remote buffer overflow vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.15. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability. | |||||
| CVE-2019-18315 | 1 Siemens | 1 Sppa-t3000 Application Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 8888/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18322 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to read and write arbitrary files on the local file system by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18321. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18330 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18329. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18283 | 1 Siemens | 1 Sppa-t3000 Application Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can gain remote code execution by sending specifically crafted objects to one of its functions. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18289 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18293, CVE-2019-18295, and CVE-2019-18296. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18284 | 1 Siemens | 1 Sppa-t3000 Application Server | 2022-02-24 | 5.0 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18296 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18289, CVE-2019-18293, and CVE-2019-18295. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18295 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18289, CVE-2019-18293, and CVE-2019-18296. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18293 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18289, CVE-2019-18295, and CVE-2019-18296. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18321 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to read and write arbitrary files on the local file system by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18322. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18316 | 1 Siemens | 1 Sppa-t3000 Application Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18314 | 1 Siemens | 1 Sppa-t3000 Application Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18313 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could gain remote code execution by sending specifically crafted objects to one of the RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18329 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18328 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18327 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18326 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18325, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18325 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18324, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18324 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server can cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18323, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-18323 | 1 Siemens | 1 Sppa-t3000 Ms3000 Migration Server | 2022-02-24 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could cause a Denial-of-Service condition and potentially gain remote code execution by sending specifically crafted packets to 5010/tcp. This vulnerability is independent from CVE-2019-18324, CVE-2019-18325, CVE-2019-18326, CVE-2019-18327, CVE-2019-18328, CVE-2019-18329, and CVE-2019-18330. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-10919 | 1 Siemens | 2 Logo\!8 Bm, Logo\!8 Bm Firmware | 2022-01-04 | 7.5 HIGH | 9.4 CRITICAL |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2021-44524 | 1 Siemens | 2 Sipass Integrated, Siveillance Identity | 2021-12-17 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal user authentication service. This could allow an unauthenticated remote attacker to trigger several actions on behalf of valid user accounts. | |||||
| CVE-2021-44523 | 1 Siemens | 2 Sipass Integrated, Siveillance Identity | 2021-12-17 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal activity feed database. This could allow an unauthenticated remote attacker to read, modify or delete activity feed entries. | |||||
| CVE-2021-27384 | 1 Siemens | 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more | 2021-12-16 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. | |||||
| CVE-2021-33719 | 1 Siemens | 3 Siprotec 5 With Cpu Variant Cp050, Siprotec 5 With Cpu Variant Cp100, Siprotec 5 With Cpu Variant Cp300 | 2021-12-16 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution. | |||||
| CVE-2021-37726 | 2 Arubanetworks, Siemens | 3 Aruba Instant, Scalance W1750d, Scalance W1750d Firmware | 2021-11-24 | 10.0 HIGH | 9.8 CRITICAL |
| A remote buffer overflow vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 8.7.x.x: 8.7.0.0 through 8.7.1.2. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability. | |||||
| CVE-2015-7705 | 4 Citrix, Netapp, Ntp and 1 more | 10 Xenserver, Clustered Data Ontap, Data Ontap and 7 more | 2021-11-17 | 7.5 HIGH | 9.8 CRITICAL |
| The rate limiting feature in NTP 4.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to have unspecified impact via a large number of crafted requests. | |||||
| CVE-2021-33725 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 5.0 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to delete arbitrary files or directories under a user controlled path and does not correctly check if the relative path is still within the intended target directory. | |||||
| CVE-2021-33724 | 1 Siemens | 1 Sinec Nms | 2021-10-18 | 5.0 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system contains an Arbitrary File Deletion vulnerability that possibly allows to delete an arbitrary file or directory under a user controlled path. | |||||
| CVE-2021-31891 | 2 Debian, Siemens | 6 Debian Linux, Desigo Cc, Gma-manager and 3 more | 2021-09-28 | 10.0 HIGH | 10.0 CRITICAL |
| A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges. | |||||
| CVE-2021-27391 | 1 Siemens | 16 Apogee Mbc \(ppc\) \(p2 Ethernet\), Apogee Mbc \(ppc\) \(p2 Ethernet\) Firmware, Apogee Mec \(ppc\) \(p2 Ethernet\) and 13 more | 2021-09-28 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges. | |||||
| CVE-2021-37181 | 1 Siemens | 3 Cerberus Dms, Desigo Cc, Desigo Cc Compact | 2021-09-24 | 7.5 HIGH | 10.0 CRITICAL |
| A vulnerability has been identified in Cerberus DMS V4.0 (All versions), Cerberus DMS V4.1 (All versions), Cerberus DMS V4.2 (All versions), Cerberus DMS V5.0 (All versions < v5.0 QU1), Desigo CC Compact V4.0 (All versions), Desigo CC Compact V4.1 (All versions), Desigo CC Compact V4.2 (All versions), Desigo CC Compact V5.0 (All versions < V5.0 QU1), Desigo CC V4.0 (All versions), Desigo CC V4.1 (All versions), Desigo CC V4.2 (All versions), Desigo CC V5.0 (All versions < V5.0 QU1). The application deserialises untrusted data without sufficient validations, that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system. The CCOM communication component used for Windows App / Click-Once and IE Web / XBAP client connectivity are affected by the vulnerability. | |||||
| CVE-2021-37184 | 1 Siemens | 1 Industrial Edge Management | 2021-09-24 | 6.8 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in Industrial Edge Management (All versions < V1.3). An unauthenticated attacker could change the the password of any user in the system under certain circumstances. With this an attacker could impersonate any valid user on an affected system. | |||||
| CVE-2019-10940 | 1 Siemens | 1 Sinema Server | 2021-09-20 | 9.0 HIGH | 9.9 CRITICAL |
| A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2020-15782 | 1 Siemens | 63 6es7510-1dj01-0ab0, 6es7510-1sj01-0ab0, 6es7511-1ak01-0ab0 and 60 more | 2021-09-14 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks. | |||||
| CVE-2021-31895 | 1 Siemens | 104 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 101 more | 2021-08-27 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in RUGGEDCOM ROS M2100 (All versions < V4.3.7), RUGGEDCOM ROS M2200 (All versions < V4.3.7), RUGGEDCOM ROS M969 (All versions < V4.3.7), RUGGEDCOM ROS RMC (All versions < V4.3.7), RUGGEDCOM ROS RMC20 (All versions < V4.3.7), RUGGEDCOM ROS RMC30 (All versions < V4.3.7), RUGGEDCOM ROS RMC40 (All versions < V4.3.7), RUGGEDCOM ROS RMC41 (All versions < V4.3.7), RUGGEDCOM ROS RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RP110 (All versions < V4.3.7), RUGGEDCOM ROS RS400 (All versions < V4.3.7), RUGGEDCOM ROS RS401 (All versions < V4.3.7), RUGGEDCOM ROS RS416 (All versions < V4.3.7), RUGGEDCOM ROS RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM ROS RS8000 (All versions < V4.3.7), RUGGEDCOM ROS RS8000A (All versions < V4.3.7), RUGGEDCOM ROS RS8000H (All versions < V4.3.7), RUGGEDCOM ROS RS8000T (All versions < V4.3.7), RUGGEDCOM ROS RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RS900G (All versions < V4.3.7), RUGGEDCOM ROS RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RS900GP (All versions < V4.3.7), RUGGEDCOM ROS RS900L (All versions < V4.3.7), RUGGEDCOM ROS RS900W (All versions < V4.3.7), RUGGEDCOM ROS RS910 (All versions < V4.3.7), RUGGEDCOM ROS RS910L (All versions < V4.3.7), RUGGEDCOM ROS RS910W (All versions < V4.3.7), RUGGEDCOM ROS RS920L (All versions < V4.3.7), RUGGEDCOM ROS RS920W (All versions < V4.3.7), RUGGEDCOM ROS RS930L (All versions < V4.3.7), RUGGEDCOM ROS RS930W (All versions < V4.3.7), RUGGEDCOM ROS RS940G (All versions < V4.3.7), RUGGEDCOM ROS RS969 (All versions < V4.3.7), RUGGEDCOM ROS RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2100 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2100P (All versions < V4.3.7), RUGGEDCOM ROS RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2200 (All versions < V4.3.7), RUGGEDCOM ROS RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG900 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG900 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG900C (All versions < V5.5.4), RUGGEDCOM ROS RSG900G V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG900G V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG900R (All versions < V5.5.4), RUGGEDCOM ROS RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSL910 (All versions < V5.5.4), RUGGEDCOM ROS RST2228 (All versions < V5.5.4), RUGGEDCOM ROS RST916C (All versions < V5.5.4), RUGGEDCOM ROS RST916P (All versions < V5.5.4), RUGGEDCOM ROS i800 (All versions < V4.3.7), RUGGEDCOM ROS i801 (All versions < V4.3.7), RUGGEDCOM ROS i802 (All versions < V4.3.7), RUGGEDCOM ROS i803 (All versions < V4.3.7). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution. | |||||
| CVE-2020-35685 | 2 Hcc-embedded, Siemens | 5 Nichestack, Sentron 3wa Com190, Sentron 3wa Com190 Firmware and 2 more | 2021-08-26 | 6.4 MEDIUM | 9.1 CRITICAL |
| An issue was discovered in HCC Nichestack 3.0. The code that generates Initial Sequence Numbers (ISNs) for TCP connections derives the ISN from an insufficiently random source. As a result, an attacker may be able to determine the ISN of current and future TCP connections and either hijack existing ones or spoof future ones. (Proper ISN generation should aim to follow at least the specifications outlined in RFC 6528.) | |||||
| CVE-2020-15798 | 1 Siemens | 4 Simatic Hmi Comfort Panels, Simatic Hmi Comfort Panels Firmware, Simatic Hmi Ktp Mobile Panels and 1 more | 2021-08-10 | 9.3 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046) | |||||
| CVE-2019-17006 | 3 Mozilla, Netapp, Siemens | 21 Network Security Services, Hci Compute Node, Hci Management Node and 18 more | 2021-07-21 | 10.0 HIGH | 9.8 CRITICAL |
| In Network Security Services (NSS) before 3.46, several cryptographic primitives had missing length checks. In cases where the application calling the library did not perform a sanity check on the inputs it could result in a crash due to a buffer overflow. | |||||
| CVE-2021-31337 | 1 Siemens | 6 Sinamics Sl150, Sinamics Sl150 Firmware, Sinamics Sm150 and 3 more | 2021-07-02 | 6.8 MEDIUM | 9.8 CRITICAL |
| The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions). | |||||
| CVE-2019-8275 | 2 Siemens, Uvnc | 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more | 2021-06-28 | 7.5 HIGH | 9.8 CRITICAL |
| UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212. | |||||
| CVE-2019-8262 | 2 Siemens, Uvnc | 4 Sinumerik Access Mymachine\/p2p, Sinumerik Pcu Base Win10 Software\/ipc, Sinumerik Pcu Base Win7 Software\/ipc and 1 more | 2021-06-28 | 7.5 HIGH | 9.8 CRITICAL |
| UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204. | |||||
| CVE-2021-27388 | 1 Siemens | 6 Sinamics Sl150, Sinamics Sl150 Firmware, Sinamics Sm150 and 3 more | 2021-06-23 | 7.5 HIGH | 9.8 CRITICAL |
| SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions). | |||||
| CVE-2019-3822 | 7 Canonical, Debian, Haxx and 4 more | 16 Ubuntu Linux, Debian Linux, Libcurl and 13 more | 2021-06-15 | 7.5 HIGH | 9.8 CRITICAL |
| libcurl versions from 7.36.0 to before 7.64.0 are vulnerable to a stack-based buffer overflow. The function creating an outgoing NTLM type-3 header (`lib/vauth/ntlm.c:Curl_auth_create_ntlm_type3_message()`), generates the request HTTP header contents based on previously received data. The check that exists to prevent the local buffer from getting overflowed is implemented wrongly (using unsigned math) and as such it does not prevent the overflow from happening. This output data can grow larger than the local buffer if very large 'nt response' data is extracted from a previous NTLMv2 header provided by the malicious or broken HTTP server. Such a 'large value' needs to be around 1000 bytes or more. The actual payload data copied to the target buffer comes from the NTLMv2 type-2 response header. | |||||
| CVE-2020-15787 | 1 Siemens | 2 Simatic Hmi United Comfort Panels, Simatic Hmi United Comfort Panels Firmware | 2021-06-08 | 5.0 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. | |||||
| CVE-2020-15786 | 1 Siemens | 8 Simatic Hmi Basic Panels 2nd Generation, Simatic Hmi Basic Panels 2nd Generation Firmware, Simatic Hmi Comfort Panels and 5 more | 2021-06-08 | 5.0 MEDIUM | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. | |||||
| CVE-2021-27389 | 1 Siemens | 2 Opcenter Quality, Qms Automotive | 2021-04-30 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection. | |||||