Search
Total
8 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-25622 | 1 Siemens | 23 Simatic Cfu Diq, Simatic Cfu Diq Firmware, Simatic Cfu Pa and 20 more | 2022-07-12 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC ET200AL IM157-1 PN (All versions), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 MF HF (All versions), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC PN/MF Coupler (All versions), SIMATIC PN/PN Coupler (All versions >= 4.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions), SINAMICS DCM (All versions with Ethernet interface), SINAMICS G110M (All versions with Ethernet interface), SINAMICS G115D (All versions with Ethernet interface), SINAMICS G120 (incl. SIPLUS variants) (All versions with Ethernet interface), SINAMICS G130 (All versions), SINAMICS G150 (All versions), SINAMICS S110 (All versions with Ethernet interface), SINAMICS S120 (incl. SIPLUS variants) (All versions), SINAMICS S150 (All versions), SINAMICS S210 (All versions), SINAMICS V90 (All versions with Ethernet interface), SIPLUS HCS4200 CIM4210 (All versions), SIPLUS HCS4200 CIM4210C (All versions), SIPLUS HCS4300 CIM4310 (All versions), SIPLUS NET PN/PN Coupler (All versions >= 4.2). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments. | |||||
| CVE-2019-19300 | 1 Siemens | 65 Ktk Ate530s, Ktk Ate530s Firmware, Sidoor Atd430w and 62 more | 2022-06-14 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), KTK ATE530S (All versions), SIDOOR ATD430W (All versions), SIDOOR ATE530S COATED (All versions), SIDOOR ATE531S (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET200AL IM157-1 PN (All versions), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 MF HF (All versions), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC MICRO-DRIVE PDC (All versions), SIMATIC PN/MF Coupler (All versions), SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) (All versions >= V4.2), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINAMICS S/G Control Unit w. PROFINET (All versions). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service. | |||||
| CVE-2019-10936 | 1 Siemens | 130 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 and 127 more | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl. Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of specially crafted UDP packets are sent to device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2019-10923 | 1 Siemens | 78 Cp1604, Cp1604 Firmware, Cp1616 and 75 more | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions < V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions < V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (All versions), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (All versions), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (All versions), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (All versions), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (All versions), SIMATIC ET200ecoPN: IO-Link Master (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions < V2.8), SIMATIC NET CP 1616 (All versions < V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < V4.7 HF29), SINAMICS G150 Control Unit (All versions < V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions < V4.7 HF34), SINAMICS S150 Control Unit (All versions < V4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations. | |||||
| CVE-2019-18336 | 1 Siemens | 23 Simatic S7-300 Cpu, Simatic S7-300 Cpu 312 Ifm, Simatic S7-300 Cpu 312 Ifm Firmware and 20 more | 2020-09-29 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known. | |||||
| CVE-2016-9158 | 1 Siemens | 21 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 314, Simatic S7-300 Cpu 315-2 Dp and 18 more | 2020-03-10 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system. | |||||
| CVE-2016-9159 | 1 Siemens | 21 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 314, Simatic S7-300 Cpu 315-2 Dp and 18 more | 2020-03-10 | 4.3 MEDIUM | 5.9 MEDIUM |
| A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices. | |||||
| CVE-2015-2177 | 1 Siemens | 2 Simatic S7-300 Cpu, Simatic S7-300 Cpu Firmware | 2018-06-02 | 7.8 HIGH | N/A |
| Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus. | |||||