Search
Total
8 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-26649 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-07-15 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions), SCALANCE X200-4P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions), SCALANCE X204IRT (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions), SCALANCE XF202-2P IRT (All versions), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices. | |||||
| CVE-2022-26648 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-07-15 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions), SCALANCE X200-4P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions), SCALANCE X204IRT (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions), SCALANCE XF202-2P IRT (All versions), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices. | |||||
| CVE-2022-26647 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-07-15 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions), SCALANCE X200-4P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X201-3P IRT PRO (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X202-2P IRT PRO (All versions), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions), SCALANCE X204IRT (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X204IRT PRO (All versions), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions), SCALANCE XF202-2P IRT (All versions), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF204IRT (All versions), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. | |||||
| CVE-2021-29998 | 2 Siemens, Windriver | 69 Ruggedcom Win Subscriber Station, Ruggedcom Win Subscriber Station Firmware, Scalance X200-4 P Irt and 66 more | 2022-07-12 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in Wind River VxWorks before 6.5. There is a possible heap overflow in dhcp client. | |||||
| CVE-2021-25669 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-05-13 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. | |||||
| CVE-2021-25668 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2022-05-01 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. | |||||
| CVE-2020-28400 | 1 Siemens | 157 Dk Standard Ethernet Controller Evaluation Kit, Dk Standard Ethernet Controller Evaluation Kit Firmware, Ek-ertec 200 Evaulation Kit and 154 more | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, RUGGEDCOM RM1224, SCALANCE M804PB, SCALANCE M812-1 ADSL-Router, SCALANCE M816-1 ADSL-Router, SCALANCE M826-2 SHDSL-Router, SCALANCE M874-2, SCALANCE M874-3, SCALANCE M876-3, SCALANCE M876-3 (ROK), SCALANCE M876-4 (EU), SCALANCE M876-4 (NAM), SCALANCE S615, SCALANCE W-1700 IEEE 802.11ac family, SCALANCE W-700 IEEE 802.11n family, SCALANCE X200-4 P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2 IRT, SCALANCE X202-2P IRT (incl. SIPLUS NET variant), SCALANCE X202-2P IRT PRO, SCALANCE X204 IRT, SCALANCE X204 IRT PRO, SCALANCE X204-2 (incl. SIPLUS NET variant), SCALANCE X204-2FM, SCALANCE X204-2LD (incl. SIPLUS NET variant), SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X206-1, SCALANCE X206-1LD (incl. SIPLUS NET variant), SCALANCE X208 (incl. SIPLUS NET variant), SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7EEC, SCALANCE X304-2FE, SCALANCE X306-1LDFE, SCALANCE X307-2EEC, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X308-2 (incl. SIPLUS NET variant), SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310FE, SCALANCE X320-1FE, SCALANCE X320-3LDFE, SCALANCE XB-200, SCALANCE XC-200, SCALANCE XF-200BA, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204 IRT, SCALANCE XF204-2 (incl. SIPLUS NET variant), SCALANCE XF204-2BA IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XM400, SCALANCE XP-200, SCALANCE XR-300WG, SCALANCE XR324-12M, SCALANCE XR324-12M TS, SCALANCE XR324-4M EEC, SCALANCE XR324-4M PoE, SCALANCE XR324-4M PoE TS, SCALANCE XR500, SIMATIC CFU PA, SIMATIC CM 1542-1, SIMATIC CP1616/CP1604, SIMATIC CP1626, SIMATIC IE/PB-LINK V3, SIMATIC MV540 H, SIMATIC MV540 S, SIMATIC MV550 H, SIMATIC MV550 S, SIMATIC MV560 U, SIMATIC MV560 X, SIMATIC NET DK-16xx PN IO, SIMATIC PROFINET Driver, SIMATIC Power Line Booster PLB, Base Module, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMOCODE proV Ethernet/IP, SIMOCODE proV PROFINET, SOFTNET-IE PNIO. Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. | |||||
| CVE-2015-1049 | 1 Siemens | 10 Scalance X-200 Series Firmware, Scalance X201-3p Irt Pro, Scalance X201-3pirt and 7 more | 2020-02-10 | 6.8 MEDIUM | N/A |
| The web server on Siemens SCALANCE X-200IRT switches with firmware before 5.2.0 allows remote attackers to hijack sessions via unspecified vectors. | |||||