| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-39182 | 1 Siemens | 1 Solid Edge | 2023-08-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-39181 | 1 Siemens | 1 Solid Edge | 2023-08-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-39187 | 1 Siemens | 1 Solid Edge | 2023-08-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-39185 | 1 Siemens | 1 Solid Edge | 2023-08-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-39186 | 1 Siemens | 1 Solid Edge | 2023-08-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-39188 | 1 Siemens | 1 Solid Edge | 2023-08-10 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted DFT files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2021-23839 | 3 Openssl, Oracle, Siemens | 8 Openssl, Business Intelligence, Enterprise Manager For Storage Management and 5 more | 2023-08-08 | 4.3 MEDIUM | 3.7 LOW |
| OpenSSL 1.0.2 supports SSLv2. If a client attempts to negotiate SSLv2 with a server that is configured to support both SSLv2 and more recent SSL and TLS versions then a check is made for a version rollback attack when unpadding an RSA signature. Clients that support SSL or TLS versions greater than SSLv2 are supposed to use a special form of padding. A server that supports greater than SSLv2 is supposed to reject connection attempts from a client where this special form of padding is present, because this indicates that a version rollback has occurred (i.e. both client and server support greater than SSLv2, and yet this is the version that is being requested). The implementation of this padding check inverted the logic so that the connection attempt is accepted if the padding is present, and rejected if it is absent. This means that such as server will accept a connection if a version rollback attack has occurred. Further the server will erroneously reject a connection if a normal SSLv2 connection attempt is made. Only OpenSSL 1.0.2 servers from version 1.0.2s to 1.0.2x are affected by this issue. In order to be vulnerable a 1.0.2 server must: 1) have configured SSLv2 support at compile time (this is off by default), 2) have configured SSLv2 support at runtime (this is off by default), 3) have configured SSLv2 ciphersuites (these are not in the default ciphersuite list) OpenSSL 1.1.1 does not have SSLv2 support and therefore is not vulnerable to this issue. The underlying error is in the implementation of the RSA_padding_check_SSLv23() function. This also affects the RSA_SSLV23_PADDING padding mode used by various other functions. Although 1.1.1 does not support SSLv2 the RSA_padding_check_SSLv23() function still exists, as does the RSA_SSLV23_PADDING padding mode. Applications that directly call that function or use that padding mode will encounter this issue. However since there is no support for the SSLv2 protocol in 1.1.1 this is considered a bug and not a security issue in that version. OpenSSL 1.0.2 is out of support and no longer receiving public updates. Premium support customers of OpenSSL 1.0.2 should upgrade to 1.0.2y. Other users should upgrade to 1.1.1j. Fixed in OpenSSL 1.0.2y (Affected 1.0.2s-1.0.2x). | |||||
| CVE-2022-2097 | 5 Debian, Fedoraproject, Netapp and 2 more | 15 Debian Linux, Fedora, Active Iq Unified Manager and 12 more | 2023-08-08 | 5.0 MEDIUM | 5.3 MEDIUM |
| AES OCB mode for 32-bit x86 platforms using the AES-NI assembly optimised implementation will not encrypt the entirety of the data under some circumstances. This could reveal sixteen bytes of data that was preexisting in the memory that wasn't written. In the special case of "in place" encryption, sixteen bytes of the plaintext would be revealed. Since OpenSSL does not support OCB based cipher suites for TLS and DTLS, they are both unaffected. Fixed in OpenSSL 3.0.5 (Affected 3.0.0-3.0.4). Fixed in OpenSSL 1.1.1q (Affected 1.1.1-1.1.1p). | |||||
| CVE-2021-23362 | 2 Npmjs, Siemens | 2 Hosted-git-info, Sinec Infrastructure Network Services | 2023-08-08 | 5.0 MEDIUM | 5.3 MEDIUM |
| The package hosted-git-info before 3.0.8 are vulnerable to Regular Expression Denial of Service (ReDoS) via regular expression shortcutMatch in the fromUrl function in index.js. The affected regular expression exhibits polynomial worst-case time complexity. | |||||
| CVE-2022-25313 | 5 Debian, Fedoraproject, Libexpat Project and 2 more | 6 Debian Linux, Fedora, Libexpat and 3 more | 2023-08-08 | 4.3 MEDIUM | 6.5 MEDIUM |
| In Expat (aka libexpat) before 2.4.5, an attacker can trigger stack exhaustion in build_model via a large nesting depth in the DTD element. | |||||
| CVE-2022-37893 | 2 Arubanetworks, Siemens | 4 Arubaos, Instant, Scalance W1750d and 1 more | 2023-08-08 | N/A | 7.8 HIGH |
| An authenticated command injection vulnerability exists in the Aruba InstantOS and ArubaOS 10 command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InstantOS that address this security vulnerability. | |||||
| CVE-2020-27737 | 1 Siemens | 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more | 2023-08-08 | 5.8 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure. | |||||
| CVE-2020-27738 | 1 Siemens | 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more | 2023-08-08 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition. | |||||
| CVE-2022-45937 | 1 Siemens | 18 Pxc00-e96.a, Pxc00-e96.a Firmware, Pxc100-e96.a and 15 more | 2023-08-08 | N/A | 6.5 MEDIUM |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials. | |||||
| CVE-2020-15795 | 1 Siemens | 2 Nucleus Net, Nucleus Source Code | 2023-08-08 | 6.8 MEDIUM | 8.1 HIGH |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition. | |||||
| CVE-2020-28388 | 4 Arm, Mips, Powerpc Project and 1 more | 8 Arm, Mips, Powerpc and 5 more | 2023-08-08 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones. | |||||
| CVE-2021-25677 | 1 Siemens | 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more | 2023-08-08 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving. | |||||
| CVE-2023-30986 | 1 Siemens | 1 Solid Edge Se2023 | 2023-08-08 | N/A | N/A |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561) | |||||
| CVE-2020-27736 | 1 Siemens | 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more | 2023-08-08 | 5.8 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. | |||||
| CVE-2020-27009 | 1 Siemens | 2 Nucleus Net, Nucleus Source Code | 2023-08-08 | 6.8 MEDIUM | 8.1 HIGH |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition. | |||||
| CVE-2023-30985 | 1 Siemens | 1 Solid Edge Se2023 | 2023-08-08 | N/A | 5.5 MEDIUM |
| A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted OBJ file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19426) | |||||
| CVE-2018-25032 | 10 Apple, Azul, Debian and 7 more | 37 Mac Os X, Macos, Zulu and 34 more | 2023-08-04 | 5.0 MEDIUM | 7.5 HIGH |
| zlib before 1.2.12 allows memory corruption when deflating (i.e., when compressing) if the input has many distant matches. | |||||
| CVE-2021-44478 | 1 Siemens | 2 Polarion Alm, Polarion Subversion Webclient | 2022-07-28 | 4.3 MEDIUM | 6.1 MEDIUM |
| A vulnerability has been identified in Polarion ALM (All versions < V21 R2 P2), Polarion WebClient for SVN (All versions). A cross-site scripting is present due to improper neutralization of data sent to the web page through the SVN WebClient in the affected product. An attacker could exploit this to execute arbitrary code and extract sensitive information by sending a specially crafted link to users with administrator privileges. | |||||
| CVE-2020-25226 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-28 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. | |||||
| CVE-2021-40364 | 1 Siemens | 2 Simatic Pcs 7, Simatic Wincc | 2022-07-28 | 2.1 LOW | 5.5 MEDIUM |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system. | |||||
| CVE-2020-15799 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-28 | 7.1 HIGH | 6.5 MEDIUM |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. | |||||
| CVE-2020-28391 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2022-07-28 | 4.3 MEDIUM | 5.9 MEDIUM |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. | |||||
| CVE-2021-22924 | 6 Debian, Fedoraproject, Haxx and 3 more | 52 Debian Linux, Fedora, Libcurl and 49 more | 2022-07-28 | 4.3 MEDIUM | 3.7 LOW |
| libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert' into account and it compared the involved paths *case insensitively*,which could lead to libcurl reusing wrong connections.File paths are, or can be, case sensitive on many systems but not all, and caneven vary depending on used file systems.The comparison also didn't include the 'issuer cert' which a transfer can setto qualify how to verify the server certificate. | |||||
| CVE-2014-0224 | 8 Fedoraproject, Filezilla-project, Mariadb and 5 more | 19 Fedora, Filezilla Server, Mariadb and 16 more | 2022-07-28 | 5.8 MEDIUM | 7.4 HIGH |
| OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability. | |||||
| CVE-2022-30938 | 1 Siemens | 6 En100 Ethernet Module, En100 Ethernet Module Dnp3 Ip Firmware, En100 Ethernet Module Iec 104 Firmware and 3 more | 2022-07-27 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition | |||||
| CVE-2022-22965 | 5 Cisco, Oracle, Siemens and 2 more | 27 Cx Cloud Agent, Communications Cloud Native Core Automated Test Suite, Communications Cloud Native Core Console and 24 more | 2022-07-25 | 7.5 HIGH | 9.8 CRITICAL |
| A Spring MVC or Spring WebFlux application running on JDK 9+ may be vulnerable to remote code execution (RCE) via data binding. The specific exploit requires the application to run on Tomcat as a WAR deployment. If the application is deployed as a Spring Boot executable jar, i.e. the default, it is not vulnerable to the exploit. However, the nature of the vulnerability is more general, and there may be other ways to exploit it. | |||||
| CVE-2021-45046 | 6 Apache, Debian, Fedoraproject and 3 more | 61 Log4j, Debian Linux, Fedora and 58 more | 2022-07-25 | 5.1 MEDIUM | 9.0 CRITICAL |
| It was found that the fix to address CVE-2021-44228 in Apache Log4j 2.15.0 was incomplete in certain non-default configurations. This could allows attackers with control over Thread Context Map (MDC) input data when the logging configuration uses a non-default Pattern Layout with either a Context Lookup (for example, $${ctx:loginId}) or a Thread Context Map pattern (%X, %mdc, or %MDC) to craft malicious input data using a JNDI Lookup pattern resulting in an information leak and remote code execution in some environments and local code execution in all environments. Log4j 2.16.0 (Java 8) and 2.12.2 (Java 7) fix this issue by removing support for message lookup patterns and disabling JNDI functionality by default. | |||||
| CVE-2021-3449 | 11 Checkpoint, Debian, Fedoraproject and 8 more | 163 Multi-domain Management, Multi-domain Management Firmware, Quantum Security Gateway and 160 more | 2022-07-25 | 4.3 MEDIUM | 5.9 MEDIUM |
| An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j). | |||||
| CVE-2020-7595 | 7 Canonical, Debian, Fedoraproject and 4 more | 32 Ubuntu Linux, Debian Linux, Fedora and 29 more | 2022-07-25 | 5.0 MEDIUM | 7.5 HIGH |
| xmlStringLenDecodeEntities in parser.c in libxml2 2.9.10 has an infinite loop in a certain end-of-file situation. | |||||
| CVE-2021-22947 | 7 Apple, Debian, Fedoraproject and 4 more | 30 Macos, Debian Linux, Fedora and 27 more | 2022-07-25 | 4.3 MEDIUM | 5.9 MEDIUM |
| When curl >= 7.20.0 and <= 7.78.0 connects to an IMAP or POP3 server to retrieve data using STARTTLS to upgrade to TLS security, the server can respond and send back multiple responses at once that curl caches. curl would then upgrade to TLS but not flush the in-queue of cached responses but instead continue using and trustingthe responses it got *before* the TLS handshake as if they were authenticated.Using this flaw, it allows a Man-In-The-Middle attacker to first inject the fake responses, then pass-through the TLS traffic from the legitimate server and trick curl into sending data back to the user thinking the attacker's injected data comes from the TLS-protected server. | |||||
| CVE-2021-22946 | 7 Apple, Debian, Fedoraproject and 4 more | 33 Macos, Debian Linux, Fedora and 30 more | 2022-07-25 | 5.0 MEDIUM | 7.5 HIGH |
| A user can tell curl >= 7.20.0 and <= 7.78.0 to require a successful upgrade to TLS when speaking to an IMAP, POP3 or FTP server (`--ssl-reqd` on the command line or`CURLOPT_USE_SSL` set to `CURLUSESSL_CONTROL` or `CURLUSESSL_ALL` withlibcurl). This requirement could be bypassed if the server would return a properly crafted but perfectly legitimate response.This flaw would then make curl silently continue its operations **withoutTLS** contrary to the instructions and expectations, exposing possibly sensitive data in clear text over the network. | |||||
| CVE-2021-42021 | 1 Siemens | 6 Siveillance Video Dlna Server, Siveillance Video Management Software 2019 R1, Siveillance Video Management Software 2019 R2 and 3 more | 2022-07-25 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application’s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks. | |||||
| CVE-2021-44003 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2022-07-25 | 4.3 MEDIUM | 5.5 MEDIUM |
| A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll is vulnerable to use of uninitialized memory while parsing user supplied TIFF files. This could allow an attacker to cause a denial-of-service condition. | |||||
| CVE-2021-44228 | 10 Apache, Bentley, Cisco and 7 more | 155 Log4j, Synchro, Synchro 4d and 152 more | 2022-07-22 | 9.3 HIGH | 10.0 CRITICAL |
| Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects. | |||||
| CVE-2019-5317 | 2 Arubanetworks, Siemens | 3 Instant, Scalance W1750d, Scalance W1750d Firmware | 2022-07-22 | 4.6 MEDIUM | 6.8 MEDIUM |
| A local authentication bypass vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x: 6.5.4.15 and below; Aruba Instant 8.3.x: 8.3.0.11 and below; Aruba Instant 8.4.x: 8.4.0.5 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability. | |||||
| CVE-2022-34465 | 1 Siemens | 2 Parasolid, Simcenter Femap | 2022-07-20 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Parasolid V33.1 (All versions), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap (All versions). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420) | |||||
| CVE-2022-34464 | 1 Siemens | 4 Sicam Gridedge Essential Arm, Sicam Gridedge Essential Gds Arm, Sicam Gridedge Essential Gds Intel and 1 more | 2022-07-19 | 2.1 LOW | 5.5 MEDIUM |
| A vulnerability has been identified in SICAM GridEdge Essential ARM (All versions), SICAM GridEdge Essential Intel (All versions < V2.7.3), SICAM GridEdge Essential with GDS ARM (All versions), SICAM GridEdge Essential with GDS Intel (All versions < V2.7.3). Affected software uses an improperly protected file to import SSH keys. Attackers with access to the filesystem of the host on which SICAM GridEdge runs, are able to inject a custom SSH key to that file. | |||||
| CVE-2022-33736 | 1 Siemens | 1 Opcenter Quality | 2022-07-19 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Opcenter Quality V13.1 (All versions < V13.1.20220624), Opcenter Quality V13.2 (All versions < V13.2.20220624). The affected applications do not properly validate login information during authentication. This could lead to denial of service condition for existing users or allow unauthenticated remote attackers to successfully login without credentials. | |||||
| CVE-2022-29884 | 1 Siemens | 6 Sicam A8000 Cp-8000, Sicam A8000 Cp-8000 Firmware, Sicam A8000 Cp-8021 and 3 more | 2022-07-19 | 7.1 HIGH | 7.5 HIGH |
| A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition. | |||||
| CVE-2022-29560 | 1 Siemens | 22 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Mx5000re and 19 more | 2022-07-19 | 10.0 HIGH | 7.2 HIGH |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < 2.15.1), RUGGEDCOM ROX MX5000RE (All versions < 2.15.1), RUGGEDCOM ROX RX1400 (All versions < 2.15.1), RUGGEDCOM ROX RX1500 (All versions < 2.15.1), RUGGEDCOM ROX RX1501 (All versions < 2.15.1), RUGGEDCOM ROX RX1510 (All versions < 2.15.1), RUGGEDCOM ROX RX1511 (All versions < 2.15.1), RUGGEDCOM ROX RX1512 (All versions < 2.15.1), RUGGEDCOM ROX RX1524 (All versions < 2.15.1), RUGGEDCOM ROX RX1536 (All versions < 2.15.1), RUGGEDCOM ROX RX5000 (All versions < 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user. | |||||
| CVE-2022-34821 | 1 Siemens | 30 Simatic Cp 1242-7 V2, Simatic Cp 1242-7 V2 Firmware, Simatic Cp 1243-1 and 27 more | 2022-07-15 | 9.3 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions). By injecting code to specific configuration options for OpenVPN, an attacker could execute arbitrary code with elevated privileges. | |||||
| CVE-2022-34820 | 1 Siemens | 30 Simatic Cp 1242-7 V2, Simatic Cp 1242-7 V2 Firmware, Simatic Cp 1243-1 and 27 more | 2022-07-15 | 9.3 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions). The application does not correctly escape some user provided fields during the authentication process. This could allow an attacker to inject custom commands and execute arbitrary code with elevated privileges. | |||||
| CVE-2022-34819 | 1 Siemens | 30 Simatic Cp 1242-7 V2, Simatic Cp 1242-7 V2 Firmware, Simatic Cp 1243-1 and 27 more | 2022-07-15 | 9.3 HIGH | 10.0 CRITICAL |
| A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 IRC (All versions >= V2.0), SIMATIC CP 1543-1 (All versions < V3.0.22), SIMATIC CP 1543SP-1 (All versions >= V2.0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions >= V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions >= V2.0), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 1543-1 (All versions < V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device. | |||||
| CVE-2021-44222 | 1 Siemens | 1 Simatic Easie Core Package | 2022-07-15 | 6.4 MEDIUM | 9.1 CRITICAL |
| A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The underlying MQTT service of affected systems does not perform authentication in the default configuration. This could allow an unauthenticated remote attacker to send arbitrary messages to the service and thereby issue arbitrary requests in the affected system. | |||||
| CVE-2021-44221 | 1 Siemens | 1 Simatic Easie Core Package | 2022-07-15 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow an remote attacker to trigger a denial of service of the affected system. | |||||