Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-2688 1 Siemens 1 Ruggedcom Rox I 2017-07-12 6.8 MEDIUM 8.8 HIGH
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF.
CVE-2017-6864 1 Siemens 1 Ruggedcom Rox I 2017-07-12 3.5 LOW 5.4 MEDIUM
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks.
CVE-2017-2687 1 Siemens 1 Ruggedcom Rox I 2017-07-12 4.3 MEDIUM 6.1 MEDIUM
Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link.
CVE-2005-2424 1 Siemens 1 Santis 50 2017-07-11 7.5 HIGH N/A
The management interface for Siemens SANTIS 50 running firmware 4.2.8.0, and possibly other products including Ericsson HN294dp and Dynalink RTA300W, allows remote attackers to access the Telnet port without authentication via certain packets to the web interface that cause the interface to freeze.
CVE-2016-9156 1 Siemens 1 Sicam Pas 2017-06-13 7.5 HIGH 7.3 HIGH
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP.
CVE-2016-9157 1 Siemens 1 Sicam Pas 2017-06-13 7.5 HIGH 9.8 CRITICAL
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to cause a Denial of Service condition and potentially lead to unauthenticated remote code execution by sending specially crafted packets to port 19234/TCP.
CVE-2016-7987 1 Siemens 8 Eta2 Firmware, Eta4 Firmware, Sicam Ak and 5 more 2017-03-14 7.8 HIGH 7.5 HIGH
An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of the SM-2558 extension module for: SICAM AK, SICAM TM 1703, SICAM BC 1703, and SICAM AK 3. Specially crafted packets sent to Port 2404/TCP could cause the affected device to go into defect mode. A cold start might be required to recover the system, a Denial-of-Service Vulnerability.
CVE-2016-8566 1 Siemens 1 Sicam Pas 2017-02-28 4.6 MEDIUM 7.8 HIGH
An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database.
CVE-2016-8567 1 Siemens 1 Sicam Pas 2017-02-28 7.5 HIGH 9.8 CRITICAL
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.
CVE-2016-9155 1 Siemens 30 Ccid1445-dn18, Ccid1445-dn18 Firmware, Ccid1445-dn28 and 27 more 2016-12-23 5.0 MEDIUM 9.8 CRITICAL
The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances.
CVE-2016-7960 1 Siemens 1 Simatic Step 7 2016-12-22 1.9 LOW 2.5 LOW
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors.
CVE-2016-8562 1 Siemens 2 Simatic Cp 1543-1, Simatic Cp 1543-1 Firmware 2016-12-22 3.5 LOW 5.3 MEDIUM
Siemens SIMATIC CP 1543-1 before 2.0.28, when SNMPv3 write access or SNMPv1 is enabled, allows remote authenticated users to cause a denial of service by modifying SNMP variables.
CVE-2015-5698 1 Siemens 2 Simatic S7 1200 Cpu, Simatic S7 1200 Cpu Firmware 2016-12-22 7.5 HIGH N/A
Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
CVE-2016-8561 1 Siemens 2 Simatic Cp 1543-1, Simatic Cp 1543-1 Firmware 2016-12-22 6.0 MEDIUM 6.6 MEDIUM
Siemens SIMATIC CP 1543-1 before 2.0.28 allows remote authenticated users to gain privileges by leveraging certain TIA-Portal access and project-data access.
CVE-2015-6675 1 Siemens 1 Ruggedcom Rugged Operating System 2016-12-22 4.3 MEDIUM N/A
Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic.
CVE-2016-7959 1 Siemens 1 Simatic Step 7 2016-12-22 1.9 LOW 4.7 MEDIUM
Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack.
CVE-2015-4174 1 Siemens 1 Climatix Bacnet\/ip 2016-12-07 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2016-2846 1 Siemens 2 Simatic S7 1200 Cpu, Simatic S7 Cpu 1200 Firmware 2016-12-03 6.4 MEDIUM 6.5 MEDIUM
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors.
CVE-2016-3155 1 Siemens 1 Apogee Insight 2016-12-03 3.6 LOW 3.4 LOW
Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors.
CVE-2015-1358 1 Siemens 1 Wincc 2016-11-30 5.0 MEDIUM N/A
The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack.
CVE-2016-7090 1 Siemens 4 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 1 more 2016-11-28 4.3 MEDIUM 4.0 MEDIUM
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.
CVE-2016-6486 1 Siemens 1 Sinema Server 2016-11-28 7.2 HIGH 7.8 HIGH
Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors.
CVE-2016-6204 1 Siemens 1 Sinema Remote Connect Server 2016-11-28 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2016-5848 1 Siemens 1 Sicam Pas 2016-11-28 1.7 LOW 6.7 MEDIUM
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges.
CVE-2016-5743 1 Siemens 5 Simatic Batch, Simatic Openpcs 7, Simatic Pcs 7 and 2 more 2016-11-28 10.0 HIGH 9.8 CRITICAL
Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets.
CVE-2016-5744 1 Siemens 1 Simatic Wincc 2016-11-28 5.0 MEDIUM 7.5 HIGH
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.
CVE-2016-5874 1 Siemens 1 Simatic Net Pc-software 2016-11-28 5.0 MEDIUM 7.5 HIGH
Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service (OPC UA service outage) via crafted TCP packets.
CVE-2016-5849 1 Siemens 1 Sicam Pas 2016-11-28 1.9 LOW 2.5 LOW
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage.
CVE-2015-2822 1 Siemens 1 Wincc 2016-11-28 4.3 MEDIUM N/A
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102.
CVE-2015-2823 1 Siemens 6 Simatic Hmi Basic Panels Generation 1, Simatic Hmi Basic Panels Generation 2, Simatic Hmi Comfort Panels and 3 more 2016-11-28 6.8 MEDIUM N/A
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
CVE-2015-1601 1 Siemens 1 Simatic Step 7 2016-11-28 6.8 MEDIUM N/A
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors.
CVE-2001-0411 1 Siemens 1 Reliant Unix 2016-10-18 5.0 MEDIUM N/A
Reliant Unix 5.44 and earlier allows remote attackers to cause a denial of service via an ICMP port unreachable packet, which causes Reliant to drop all connections to the source address of the packet.
CVE-2015-1594 1 Siemens 5 Simatic Cfc, Simatic Prosave, Simatic Step 7 and 2 more 2016-08-24 6.9 MEDIUM N/A
Untrusted search path vulnerability in Siemens SIMATIC ProSave before 13 SP1; SIMATIC CFC before 8.0 SP4 Upd9 and 8.1 before Upd1; SIMATIC STEP 7 before 5.5 SP1 HF2, 5.5 SP2 before HF7, 5.5 SP3, and 5.5 SP4 before HF4; SIMOTION Scout before 4.4; and STARTER before 4.4 HF3 allows local users to gain privileges via a Trojan horse application file.
CVE-2016-1488 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2016-03-04 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2014-5233 2 Apple, Siemens 2 Iphone Os, Simatic Wincc Sm\@rtclient 2015-11-13 1.9 LOW N/A
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism.
CVE-2014-5232 2 Apple, Siemens 2 Iphone Os, Simatic Wincc Sm\@rtclient 2015-11-13 1.9 LOW N/A
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state.
CVE-2014-5231 2 Apple, Siemens 2 Iphone Os, Simatic Wincc Sm\@rtclient 2015-11-13 2.1 LOW N/A
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors.
CVE-2015-5717 1 Siemens 1 Compas 2015-11-04 5.8 MEDIUM N/A
The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
CVE-2014-2732 1 Siemens 1 Sinema Server 2015-10-08 5.0 MEDIUM N/A
Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80.
CVE-2015-5386 1 Siemens 2 Sicam Mic, Sicam Mic Firmware 2015-07-17 9.3 HIGH N/A
Siemens SICAM MIC devices with firmware before 2404 allow remote attackers to bypass authentication and obtain administrative access via unspecified HTTP requests.
CVE-2015-1595 1 Siemens 1 Spcanywhere 2015-07-15 4.3 MEDIUM N/A
The Siemens SPCanywhere application for Android and iOS does not use encryption during lookups of system ID to IP address mappings, which allows man-in-the-middle attackers to discover alarm IP addresses and spoof servers by intercepting the client-server data stream.
CVE-2015-3610 1 Siemens 1 Homecontrol For Room Automation 2015-05-07 5.4 MEDIUM N/A
The Siemens HomeControl for Room Automation application before 2.0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information or modify data via a crafted certificate.
CVE-2015-1602 1 Siemens 1 Simatic Step 7 2015-04-23 2.1 LOW N/A
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files.
CVE-2015-1599 1 Siemens 1 Spcanywhere 2015-03-09 2.1 LOW N/A
The Siemens SPCanywhere application for iOS allows physically proximate attackers to bypass intended access restrictions by leveraging a filesystem architectural error.
CVE-2015-1596 1 Siemens 1 Spcanywhere 2015-03-09 5.8 MEDIUM N/A
The Siemens SPCanywhere application for Android and iOS does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
CVE-2015-1598 1 Siemens 1 Spcanywhere 2015-03-09 2.1 LOW N/A
The Siemens SPCanywhere application for Android does not properly store application passwords, which allows physically proximate attackers to obtain sensitive information by examining the device filesystem.
CVE-2015-1597 1 Siemens 1 Spcanywhere 2015-03-09 6.8 MEDIUM N/A
The Siemens SPCanywhere application for Android does not use encryption during the loading of code, which allows man-in-the-middle attackers to execute arbitrary code by modifying the client-server data stream.
CVE-2014-9369 1 Siemens 6 Spc4000, Spc4000 Firmware, Spc5000 and 3 more 2015-03-09 7.8 HIGH N/A
Siemens SPC controllers SPC4000, SPC5000, and SPC6000 before 3.6.0 allow remote attackers to cause a denial of service (device restart) via crafted packets.
CVE-2015-1356 1 Siemens 1 Simatic Step 7 2015-02-18 4.4 MEDIUM N/A
Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file.
CVE-2015-1355 1 Siemens 1 Simatic Step 7 2015-02-18 2.1 LOW N/A
Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack.