| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-26845 | 1 Abb | 1 Esoms | 2021-06-25 | 5.0 MEDIUM | 7.5 HIGH |
| Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions prior to 6.0.4.2.2; 6.1 versions prior to 6.1.4; 6.3 versions prior to 6.3. | |||||
| CVE-2020-24686 | 1 Abb | 12 Pm554, Pm554 Firmware, Pm556 and 9 more | 2021-03-05 | 5.0 MEDIUM | 7.5 HIGH |
| The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet. | |||||
| CVE-2020-24685 | 1 Abb | 3 Ac500 Cpu Firmware, Pm573-eth, Pm583-eth | 2021-02-16 | 5.0 MEDIUM | 8.6 HIGH |
| An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. Vulnerability allows attacker to stop the PLC. After stopping (ERR LED flashing red), physical access to the PLC is required in order to restart the application. This issue affects: ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions. | |||||
| CVE-2019-18997 | 1 Abb | 1 Pb610 Panel Builder 600 | 2020-10-22 | 5.0 MEDIUM | 7.5 HIGH |
| The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access. | |||||
| CVE-2019-19089 | 1 Abb | 1 Esoms | 2020-10-19 | 4.3 MEDIUM | 6.1 MEDIUM |
| For ABB eSOMS versions 4.0 to 6.0.3, the X-Content-Type-Options Header is missing in the HTTP response, potentially causing the response body to be interpreted and displayed as different content type other than declared. A possible attack scenario would be unauthorized code execution via text interpreted as JavaScript. | |||||
| CVE-2019-7230 | 1 Abb | 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware | 2020-08-24 | 5.8 MEDIUM | 8.8 HIGH |
| The ABB IDAL FTP server mishandles format strings in a username during the authentication process. Attempting to authenticate with the username %s%p%x%d will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack. | |||||
| CVE-2019-7232 | 1 Abb | 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware | 2020-08-24 | 5.8 MEDIUM | 8.8 HIGH |
| The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is sent in a web request. The Host header value overflows a buffer and overwrites a Structured Exception Handler (SEH) address. An unauthenticated attacker can submit a Host header value of 2047 bytes or more to overflow the buffer and overwrite the SEH address, which can then be leveraged to execute attacker-controlled code on the server. | |||||
| CVE-2019-7228 | 1 Abb | 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware | 2020-08-24 | 5.8 MEDIUM | 8.8 HIGH |
| The ABB IDAL HTTP server mishandles format strings in a username or cookie during the authentication process. Attempting to authenticate with the username %25s%25p%25x%25n will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack. | |||||
| CVE-2020-10287 | 1 Abb | 4 Irb140, Irb140 Firmware, Irc5 and 1 more | 2020-07-24 | 7.5 HIGH | 9.8 CRITICAL |
| The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them). | |||||
| CVE-2020-10288 | 2 Abb, Windriver | 4 Irb140, Irc5, Robotware and 1 more | 2020-07-23 | 7.5 HIGH | 9.8 CRITICAL |
| IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted. | |||||
| CVE-2020-8479 | 1 Abb | 3 800xa System, Compact Hmi, Control Builder Safe | 2020-06-09 | 7.5 HIGH | 9.8 CRITICAL |
| For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling. | |||||
| CVE-2020-8476 | 1 Abb | 3 800xa System, Compact Hmi, Control Builder Safe | 2020-06-09 | 5.0 MEDIUM | 7.5 HIGH |
| For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service. | |||||
| CVE-2020-8475 | 1 Abb | 3 800xa System, Compact Hmi, Control Builder Safe | 2020-06-09 | 2.1 LOW | 7.5 HIGH |
| For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service. | |||||
| CVE-2020-8471 | 1 Abb | 3 800xa System, Compact Hmi, Control Builder Safe | 2020-06-09 | 4.6 MEDIUM | 7.8 HIGH |
| For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code. | |||||
| CVE-2020-8482 | 1 Abb | 1 Device Library Wizard | 2020-06-01 | 2.1 LOW | 5.5 MEDIUM |
| Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data | |||||
| CVE-2020-8473 | 1 Abb | 1 800xa Base System | 2020-05-14 | 6.8 MEDIUM | 7.8 HIGH |
| Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications. | |||||
| CVE-2020-8472 | 1 Abb | 5 Ac800m, Base Software, Control Builder M and 2 more | 2020-05-14 | 6.8 MEDIUM | 7.8 HIGH |
| Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications. | |||||
| CVE-2020-8478 | 1 Abb | 4 Ac800m, Base Software, Mms Server and 1 more | 2020-05-13 | 2.1 LOW | 3.3 LOW |
| Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder. | |||||
| CVE-2020-8489 | 1 Abb | 1 800xa Information Management | 2020-05-08 | 4.6 MEDIUM | 7.8 HIGH |
| Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable. | |||||
| CVE-2020-8488 | 1 Abb | 1 800xa Batch Management | 2020-05-08 | 4.6 MEDIUM | 7.8 HIGH |
| Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities. | |||||
| CVE-2020-8484 | 1 Abb | 1 800xa | 2020-05-08 | 4.6 MEDIUM | 7.8 HIGH |
| Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. | |||||
| CVE-2020-8487 | 1 Abb | 1 800xa Base System | 2020-05-08 | 4.6 MEDIUM | 7.8 HIGH |
| Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | |||||
| CVE-2020-8486 | 1 Abb | 1 800xa Rnrp | 2020-05-07 | 4.6 MEDIUM | 7.8 HIGH |
| Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | |||||
| CVE-2020-8485 | 1 Abb | 1 800xa | 2020-05-07 | 4.6 MEDIUM | 7.8 HIGH |
| Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. | |||||
| CVE-2019-5620 | 2 Abb, Microsoft | 3 Microscada Pro Sys600, Windows 7, Windows Xp | 2020-05-06 | 7.5 HIGH | 9.8 CRITICAL |
| ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function. | |||||
| CVE-2020-8477 | 1 Abb | 1 800xa Information Manager | 2020-04-30 | 6.8 MEDIUM | 8.8 HIGH |
| The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code. | |||||
| CVE-2020-8474 | 1 Abb | 1 800xa Base System | 2020-04-30 | 4.6 MEDIUM | 7.8 HIGH |
| Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction. | |||||
| CVE-2019-19105 | 2 Abb, Busch-jaeger | 4 Tg\/s3.2, Tg\/s3.2 Firmware, 6186\/11 and 1 more | 2020-04-29 | 2.1 LOW | 5.5 MEDIUM |
| The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext. | |||||
| CVE-2019-19090 | 1 Abb | 1 Esoms | 2020-04-03 | 3.5 LOW | 3.5 LOW |
| For ABB eSOMS versions 4.0 to 6.0.2, the Secure Flag is not set in the HTTP response header. Unencrypted connections might access the cookie information, thus making it susceptible to eavesdropping. | |||||
| CVE-2019-19091 | 1 Abb | 1 Esoms | 2020-04-03 | 4.0 MEDIUM | 4.3 MEDIUM |
| For ABB eSOMS versions 4.0 to 6.0.3, HTTPS responses contain comments with sensitive information about the application. An attacker might use this detail information to specifically craft the attack. | |||||
| CVE-2019-19003 | 1 Abb | 1 Esoms | 2020-04-03 | 4.3 MEDIUM | 6.1 MEDIUM |
| For ABB eSOMS versions 4.0 to 6.0.2, the HTTPOnly flag is not set. This can allow Javascript to access the cookie contents, which in turn might enable Cross Site Scripting. | |||||
| CVE-2019-19002 | 1 Abb | 1 Esoms | 2020-04-03 | 3.5 LOW | 5.4 MEDIUM |
| For ABB eSOMS versions 4.0 to 6.0.2, the X-XSS-Protection HTTP response header is not set in responses from the web server. For older web browser not supporting Content Security Policy, this might increase the risk of Cross Site Scripting. | |||||
| CVE-2019-19000 | 1 Abb | 1 Esoms | 2020-04-03 | 6.4 MEDIUM | 6.5 MEDIUM |
| For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. This can potentially allow browsers and proxies to cache sensitive information. | |||||
| CVE-2019-19001 | 1 Abb | 1 Esoms | 2020-04-03 | 4.3 MEDIUM | 6.5 MEDIUM |
| For ABB eSOMS versions 4.0 to 6.0.2, the X-Frame-Options header is not configured in HTTP response. This can potentially allow 'ClickJacking' attacks where an attacker can frame parts of the application on a malicious web site, revealing sensitive user information such as authentication credentials. | |||||
| CVE-2019-19097 | 1 Abb | 1 Esoms | 2020-04-03 | 4.3 MEDIUM | 7.5 HIGH |
| ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers. If a connection is enabled using such a cipher, an attacker might be able to eavesdrop and/or intercept the connection. | |||||
| CVE-2019-19096 | 1 Abb | 1 Esoms | 2020-04-03 | 3.6 LOW | 6.1 MEDIUM |
| The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality. | |||||
| CVE-2019-19095 | 1 Abb | 1 Esoms | 2020-04-03 | 3.5 LOW | 5.4 MEDIUM |
| Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing malicious content in the database. | |||||
| CVE-2019-19094 | 1 Abb | 1 Esoms | 2020-04-03 | 6.5 MEDIUM | 7.6 HIGH |
| Lack of input checks for SQL queries in ABB eSOMS versions 3.9 to 6.0.3 might allow an attacker SQL injection attacks against the backend database. | |||||
| CVE-2019-19093 | 1 Abb | 1 Esoms | 2020-04-03 | 6.4 MEDIUM | 6.5 MEDIUM |
| eSOMS versions 4.0 to 6.0.3 do not enforce password complexity settings, potentially resulting in lower access security due to insecure user passwords. | |||||
| CVE-2019-19092 | 1 Abb | 1 Esoms | 2020-04-03 | 3.5 LOW | 3.5 LOW |
| ABB eSOMS versions 4.0 to 6.0.3 use ASP.NET Viewstate without Message Authentication Code (MAC). Alterations to Viewstate might thus not be noticed. | |||||
| CVE-2019-18996 | 1 Abb | 1 Pb610 Panel Builder 600 | 2020-02-10 | 4.4 MEDIUM | 7.8 HIGH |
| Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context. | |||||
| CVE-2019-10995 | 1 Abb | 16 Cp651, Cp651-web, Cp651-web Firmware and 13 more | 2020-01-24 | 5.8 MEDIUM | 8.8 HIGH |
| ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. | |||||
| CVE-2019-18995 | 1 Abb | 1 Pb610 Panel Builder 600 | 2019-12-31 | 5.0 MEDIUM | 5.3 MEDIUM |
| The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting. | |||||
| CVE-2019-18994 | 1 Abb | 1 Pb610 Panel Builder 600 | 2019-12-31 | 3.5 LOW | 6.5 MEDIUM |
| Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service. | |||||
| CVE-2019-18253 | 1 Abb | 2 Relion 670, Relion 670 Firmware | 2019-12-17 | 7.5 HIGH | 10.0 CRITICAL |
| An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior) outside the intended directory. | |||||
| CVE-2019-18247 | 1 Abb | 4 Relion 650, Relion 650 Firmware, Relion 670 and 1 more | 2019-12-11 | 7.8 HIGH | 7.5 HIGH |
| An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could cause a denial of service. | |||||
| CVE-2019-7231 | 1 Abb | 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware | 2019-10-09 | 2.7 LOW | 5.7 MEDIUM |
| The ABB IDAL FTP server is vulnerable to a buffer overflow when a long string is sent by an authenticated attacker. This overflow is handled, but terminates the process. An authenticated attacker can send a FTP command string of 472 bytes or more to overflow a buffer, causing an exception that terminates the server. | |||||
| CVE-2019-7227 | 1 Abb | 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware | 2019-10-09 | 4.1 MEDIUM | 7.3 HIGH |
| In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to become an authenticated attacker. | |||||
| CVE-2019-7226 | 1 Abb | 2 Pb610 Panel Builder 600, Pb610 Panel Builder 600 Firmware | 2019-10-09 | 5.8 MEDIUM | 8.8 HIGH |
| The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response. | |||||
| CVE-2019-7225 | 1 Abb | 32 Cp620, Cp620-web, Cp620-web Firmware and 29 more | 2019-10-09 | 5.8 MEDIUM | 8.8 HIGH |
| The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are the idal123 password for the IdalMaster account, and the exor password for the exor account. These credentials are used over both HTTP(S) and FTP. There is no option to disable or change these undocumented credentials. An attacker can use these credentials to login to ABB HMI to read/write HMI configuration files and also to reset the device. This affects ABB CP635 HMI, CP600 HMIClient, Panel Builder 600, IDAL FTP server, IDAL HTTP server, and multiple other HMI components. | |||||