CVE-2021-41536 1 Siemens 1 Solid Edge 2021-10-01 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).
CVE-2021-31891 2 Debian, Siemens 6 Debian Linux, Desigo Cc, Gma-manager and 3 more 2021-09-28 10.0 HIGH 10.0 CRITICAL
A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges.
CVE-2021-27391 1 Siemens 16 Apogee Mbc \(ppc\) \(p2 Ethernet\), Apogee Mbc \(ppc\) \(p2 Ethernet\) Firmware, Apogee Mec \(ppc\) \(p2 Ethernet\) and 13 more 2021-09-28 10.0 HIGH 9.8 CRITICAL
A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.
CVE-2021-40357 1 Siemens 1 Teamcenter Active Workspace 2021-09-28 4.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.10), Teamcenter Active Workspace V5.0 (All versions < V5.0.8), Teamcenter Active Workspace V5.1 (All versions < V5.1.5), Teamcenter Active Workspace V5.2 (All versions < V5.2.1). A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host.
CVE-2021-40356 1 Siemens 1 Teamcenter Visualization 2021-09-28 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.
CVE-2021-40355 1 Siemens 1 Teamcenter Visualization 2021-09-28 6.5 MEDIUM 8.8 HIGH
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly.
CVE-2021-40354 1 Siemens 1 Teamcenter Visualization 2021-09-28 5.5 MEDIUM 7.1 HIGH
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The "surrogate" functionality on the user profile of the application does not perform sufficient access control that could lead to an account takeover. Any profile on the application can perform this attack and access any other user assigned tasks via the "inbox/surrogate tasks".
CVE-2021-37181 1 Siemens 3 Cerberus Dms, Desigo Cc, Desigo Cc Compact 2021-09-24 7.5 HIGH 10.0 CRITICAL
A vulnerability has been identified in Cerberus DMS V4.0 (All versions), Cerberus DMS V4.1 (All versions), Cerberus DMS V4.2 (All versions), Cerberus DMS V5.0 (All versions < v5.0 QU1), Desigo CC Compact V4.0 (All versions), Desigo CC Compact V4.1 (All versions), Desigo CC Compact V4.2 (All versions), Desigo CC Compact V5.0 (All versions < V5.0 QU1), Desigo CC V4.0 (All versions), Desigo CC V4.1 (All versions), Desigo CC V4.2 (All versions), Desigo CC V5.0 (All versions < V5.0 QU1). The application deserialises untrusted data without sufficient validations, that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system. The CCOM communication component used for Windows App / Click-Once and IE Web / XBAP client connectivity are affected by the vulnerability.
CVE-2021-37201 1 Siemens 1 Sinec Network Management System 2021-09-24 6.8 MEDIUM 8.8 HIGH
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINEC NMS configuration by tricking an unsuspecting user with administrative privileges to click on a malicious link.
CVE-2021-37200 1 Siemens 1 Sinec Network Management System 2021-09-24 4.0 MEDIUM 7.7 HIGH
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). An attacker with access to the webserver of an affected system could download arbitrary files from the underlying filesystem by sending a specially crafted HTTP request.
CVE-2021-37184 1 Siemens 1 Industrial Edge Management 2021-09-24 6.8 MEDIUM 9.8 CRITICAL
A vulnerability has been identified in Industrial Edge Management (All versions < V1.3). An unauthenticated attacker could change the the password of any user in the system under certain circumstances. With this an attacker could impersonate any valid user on an affected system.
CVE-2021-37190 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve VPN connection for a known user.
CVE-2021-37183 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software allows sending send-to-sleep notifications to the managed devices. An unauthenticated attacker in the same network of the affected system can abuse these notifications to cause a Denial-of-Service condition in the managed devices.
CVE-2021-37193 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). An unauthenticated attacker in the same network of the affected system could manipulate certain parameters and set a valid user of the affected software as invalid (or vice-versa).
CVE-2021-37191 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). An unauthenticated attacker in the same network of the affected system could brute force the usernames from the affected software.
CVE-2021-37177 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system.
CVE-2021-37192 1 Siemens 1 Sinema Remote Connect Server 2021-09-23 3.3 LOW 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve a list of network devices a known user can manage.
CVE-2021-37176 1 Siemens 1 Simcenter Femap 2021-09-23 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260)
CVE-2021-37175 1 Siemens 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more 2021-09-23 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices.
CVE-2021-37174 1 Siemens 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more 2021-09-23 9.0 HIGH 8.8 HIGH
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access.
CVE-2021-25665 1 Siemens 1 Simcenter Star-ccm\+ 2021-09-23 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700)
CVE-2019-10941 1 Siemens 1 Sinema Server 2021-09-23 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.
CVE-2007-1917 8 Apple, Hp, Ibm and 5 more 11 Macos, Hp-ux, Tru64 and 8 more 2021-09-22 10.0 HIGH N/A
Buffer overflow in the SYSTEM_CREATE_INSTANCE function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
CVE-2007-1915 7 Apple, Hp, Ibm and 4 more 10 Macos, Hp-ux, Tru64 and 7 more 2021-09-22 7.5 HIGH N/A
Buffer overflow in the RFC_START_PROGRAM function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
CVE-2007-1916 8 Apple, Hp, Ibm and 5 more 11 Macos, Hp-ux, Tru64 and 8 more 2021-09-22 10.0 HIGH N/A
Buffer overflow in the RFC_START_GUI function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
CVE-2007-1918 8 Apple, Hp, Ibm and 5 more 11 Macos, Hp-ux, Tru64 and 8 more 2021-09-22 5.0 MEDIUM N/A
The RFC_SET_REG_SERVER_PROPERTY function in the SAP RFC Library 6.40 and 7.00 before 20070109 implements an option for exclusive access to an RFC server, which allows remote attackers to cause a denial of service (client lockout) via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
CVE-2007-1913 8 Apple, Hp, Ibm and 5 more 11 Macos, Hp-ux, Tru64 and 8 more 2021-09-22 5.0 MEDIUM N/A
The TRUSTED_SYSTEM_SECURITY function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to verify the existence of users and groups on systems and domains via unspecified vectors, a different vulnerability than CVE-2006-6010. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
CVE-2021-31343 1 Siemens 4 Solid Edge Se2020, Solid Edge Se2020 Firmware, Solid Edge Se2021 and 1 more 2021-09-21 6.8 MEDIUM 8.8 HIGH
The jutil.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocation structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-31342 1 Siemens 4 Solid Edge Se2020, Solid Edge Se2020 Firmware, Solid Edge Se2021 and 1 more 2021-09-21 6.8 MEDIUM 8.8 HIGH
The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
CVE-2021-32936 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 6.8 MEDIUM 7.8 HIGH
An out-of-bounds write issue exists in the DXF file-recovering procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
CVE-2021-32946 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 6.8 MEDIUM 7.8 HIGH
An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
CVE-2021-32938 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 5.8 MEDIUM 7.1 HIGH
Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.
CVE-2021-32944 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 6.8 MEDIUM 7.8 HIGH
A use-after-free issue exists in the DGN file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.
CVE-2021-32940 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 5.8 MEDIUM 7.1 HIGH
An out-of-bounds read issue exists in the DWG file-recovering procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.
CVE-2021-32950 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 5.8 MEDIUM 7.1 HIGH
An out-of-bounds read issue exists within the parsing of DXF files in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of-service condition or read sensitive information from memory locations.
CVE-2021-32948 2 Opendesign, Siemens 3 Drawings Sdk, Jt2go, Teamcenter Visualization 2021-09-21 6.8 MEDIUM 7.8 HIGH
An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
CVE-2021-33738 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-09-21 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)
CVE-2021-34318 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-09-20 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13403)
CVE-2021-34313 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-09-20 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13354)
CVE-2021-34330 1 Siemens 2 Jt2go, Teamcenter Visualization 2021-09-20 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13430)
CVE-2019-10940 1 Siemens 1 Sinema Server 2021-09-20 9.0 HIGH 9.9 CRITICAL
A vulnerability has been identified in SINEMA Server (All versions < V14.0 SP2 Update 1). Incorrect session validation could allow an attacker with a valid session, with low privileges, to perform firmware updates and other administrative operations on connected devices. The security vulnerability could be exploited by an attacker with network access to the affected system. An attacker must have access to a low privileged account in order to exploit the vulnerability. An attacker could use the vulnerability to compromise confidentiality, integrity, and availability of the affected system and underlying components. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2020-7461 2 Freebsd, Siemens 5 Freebsd, Simatic Rf350m, Simatic Rf350m Firmware and 2 more 2021-09-16 7.5 HIGH 7.3 HIGH
In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.
CVE-2020-9273 5 Debian, Fedoraproject, Opensuse and 2 more 9 Debian Linux, Fedora, Backports Sle and 6 more 2021-09-14 9.0 HIGH 8.8 HIGH
In ProFTPD 1.3.7, it is possible to corrupt the memory pool by interrupting the data transfer channel. This triggers a use-after-free in alloc_pool in pool.c, and possible remote code execution.
CVE-2020-15782 1 Siemens 63 6es7510-1dj01-0ab0, 6es7510-1sj01-0ab0, 6es7511-1ak01-0ab0 and 60 more 2021-09-14 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
CVE-2021-31895 1 Siemens 104 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 101 more 2021-08-27 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in RUGGEDCOM ROS M2100 (All versions < V4.3.7), RUGGEDCOM ROS M2200 (All versions < V4.3.7), RUGGEDCOM ROS M969 (All versions < V4.3.7), RUGGEDCOM ROS RMC (All versions < V4.3.7), RUGGEDCOM ROS RMC20 (All versions < V4.3.7), RUGGEDCOM ROS RMC30 (All versions < V4.3.7), RUGGEDCOM ROS RMC40 (All versions < V4.3.7), RUGGEDCOM ROS RMC41 (All versions < V4.3.7), RUGGEDCOM ROS RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RP110 (All versions < V4.3.7), RUGGEDCOM ROS RS400 (All versions < V4.3.7), RUGGEDCOM ROS RS401 (All versions < V4.3.7), RUGGEDCOM ROS RS416 (All versions < V4.3.7), RUGGEDCOM ROS RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM ROS RS8000 (All versions < V4.3.7), RUGGEDCOM ROS RS8000A (All versions < V4.3.7), RUGGEDCOM ROS RS8000H (All versions < V4.3.7), RUGGEDCOM ROS RS8000T (All versions < V4.3.7), RUGGEDCOM ROS RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RS900G (All versions < V4.3.7), RUGGEDCOM ROS RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RS900GP (All versions < V4.3.7), RUGGEDCOM ROS RS900L (All versions < V4.3.7), RUGGEDCOM ROS RS900W (All versions < V4.3.7), RUGGEDCOM ROS RS910 (All versions < V4.3.7), RUGGEDCOM ROS RS910L (All versions < V4.3.7), RUGGEDCOM ROS RS910W (All versions < V4.3.7), RUGGEDCOM ROS RS920L (All versions < V4.3.7), RUGGEDCOM ROS RS920W (All versions < V4.3.7), RUGGEDCOM ROS RS930L (All versions < V4.3.7), RUGGEDCOM ROS RS930W (All versions < V4.3.7), RUGGEDCOM ROS RS940G (All versions < V4.3.7), RUGGEDCOM ROS RS969 (All versions < V4.3.7), RUGGEDCOM ROS RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2100 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2100P (All versions < V4.3.7), RUGGEDCOM ROS RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2200 (All versions < V4.3.7), RUGGEDCOM ROS RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG900 V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG900 V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG900C (All versions < V5.5.4), RUGGEDCOM ROS RSG900G V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG900G V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSG900R (All versions < V5.5.4), RUGGEDCOM ROS RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM ROS RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM ROS RSL910 (All versions < V5.5.4), RUGGEDCOM ROS RST2228 (All versions < V5.5.4), RUGGEDCOM ROS RST916C (All versions < V5.5.4), RUGGEDCOM ROS RST916P (All versions < V5.5.4), RUGGEDCOM ROS i800 (All versions < V4.3.7), RUGGEDCOM ROS i801 (All versions < V4.3.7), RUGGEDCOM ROS i802 (All versions < V4.3.7), RUGGEDCOM ROS i803 (All versions < V4.3.7). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution.
CVE-2020-35684 2 Hcc-embedded, Siemens 5 Nichestack, Sentron 3wa Com190, Sentron 3wa Com190 Firmware and 2 more 2021-08-26 5.0 MEDIUM 7.5 HIGH
An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible).
CVE-2020-35685 2 Hcc-embedded, Siemens 5 Nichestack, Sentron 3wa Com190, Sentron 3wa Com190 Firmware and 2 more 2021-08-26 6.4 MEDIUM 9.1 CRITICAL
An issue was discovered in HCC Nichestack 3.0. The code that generates Initial Sequence Numbers (ISNs) for TCP connections derives the ISN from an insufficiently random source. As a result, an attacker may be able to determine the ISN of current and future TCP connections and either hijack existing ones or spoof future ones. (Proper ISN generation should aim to follow at least the specifications outlined in RFC 6528.)
CVE-2021-31401 2 Hcc-embedded, Siemens 5 Nichestack, Sentron 3wa Com190, Sentron 3wa Com190 Firmware and 2 more 2021-08-26 5.0 MEDIUM 7.5 HIGH
An issue was discovered in tcp_rcv() in nptcp.c in HCC embedded InterNiche 4.0.1. The TCP header processing code doesn't sanitize the value of the IP total length field (header length + data length). With a crafted IP packet, an integer overflow occurs whenever the value of the IP data length is calculated by subtracting the length of the header from the total length of the IP packet.
CVE-2021-31338 1 Siemens 1 Sinema Remote Connect 2021-08-26 4.6 MEDIUM 7.8 HIGH
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to escalate privileges and execute own code on the device.
CVE-2021-37178 1 Siemens 2 Solid Edge Se2021, Solid Edge Se2021 Firmware 2021-08-20 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). An XML external entity injection vulnerability in the underlying XML parser could cause the affected application to disclose arbitrary files to remote attackers by loading a specially crafted xml file.