Search
Total
109 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-5155 | 1 Schneider-electric | 1 Wonderware Historian | 2019-10-03 | 7.5 HIGH | 7.3 HIGH |
| An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well. | |||||
| CVE-2017-4971 | 1 Pivotal | 1 Spring Web Flow | 2019-10-03 | 4.3 MEDIUM | 5.9 MEDIUM |
| An issue was discovered in Pivotal Spring Web Flow through 2.4.4. Applications that do not change the value of the MvcViewFactoryCreator useSpringBinding property which is disabled by default (i.e., set to 'false') can be vulnerable to malicious EL expressions in view states that process form submissions but do not have a sub-element to declare explicit data binding property mappings. | |||||
| CVE-2017-12739 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2019-10-03 | 10.0 HIGH | 9.8 CRITICAL |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. | |||||
| CVE-2017-8039 | 1 Pivotal | 1 Spring Web Flow | 2019-10-03 | 4.3 MEDIUM | 5.9 MEDIUM |
| An issue was discovered in Pivotal Spring Web Flow through 2.4.5. Applications that do not change the value of the MvcViewFactoryCreator useSpringBinding property which is disabled by default (i.e., set to 'false') can be vulnerable to malicious EL expressions in view states that process form submissions but do not have a sub-element to declare explicit data binding property mappings. NOTE: this issue exists because of an incomplete fix for CVE-2017-4971. | |||||
| CVE-2018-3667 | 1 Intel | 1 Processor Diagnostic Tool | 2019-10-03 | 4.6 MEDIUM | 7.8 HIGH |
| Installation tool IPDT (Intel Processor Diagnostic Tool) 4.1.0.24 sets permissions of installed files incorrectly, allowing for execution of arbitrary code and potential privilege escalation. | |||||
| CVE-2018-3591 | 1 Qualcomm | 54 Mdm9206, Mdm9206 Firmware, Mdm9607 and 51 more | 2019-10-03 | 10.0 HIGH | 9.8 CRITICAL |
| In Android before security patch level 2018-04-05 on Qualcomm Snapdragon Mobile and Snapdragon Wear MDM9206, MDM9607, MDM9635M, MDM9650, MDM9655, SD 210/SD 212/SD 205, SD 410/12, SD 425, SD 427, SD 430, SD 435, SD 450, SD 615/16/SD 415, SD 625, SD 650/52, SD 820, SD 835, SD 845, SDM630, SDM636, SDM660, Snapdragon_High_Med_2016, the default build configuration of deviceprogrammer in BOOT.BF.3.0 enables the flag SKIP_SECBOOT_CHECK_NOT_RECOMMENDED_BY_QUALCOMM which will open up the peek and poke commands to any memory location on the target. | |||||
| CVE-2018-20402 | 1 Safe | 1 Fme Server | 2019-10-03 | 6.5 MEDIUM | 8.8 HIGH |
| Safe Software FME Server through 2018.1 creates and enables three additional accounts in addition to the initial administrator account. The passwords to the three accounts are the same as the usernames, which are guest, user, and author. Logging in with these accounts will grant any user the default privilege roles that were also created for each of the accounts. | |||||
| CVE-2018-20052 | 1 Cerner | 2 Connectivity Engine 4, Connectivity Engine 4 Firmware | 2019-10-03 | 7.2 HIGH | 7.8 HIGH |
| An issue was discovered on Cerner Connectivity Engine (CCE) 4 devices. The user running the main CCE firmware has NOPASSWD sudo privileges to several utilities that could be used to escalate privileges to root. One example is the "sudo ln -s /tmp/script /etc/cron.hourly/script" command. | |||||
| CVE-2018-16752 | 1 Linknet-usa | 2 Lw-n605r, Lw-n605r Firmware | 2019-10-03 | 9.0 HIGH | 8.8 HIGH |
| LINK-NET LW-N605R devices with firmware 12.20.2.1486 allow Remote Code Execution via shell metacharacters in the HOST field of the ping feature at adm/systools.asp. Authentication is needed but the default password of admin for the admin account may be used in some cases. | |||||