Filtered by vendor Siemens
Subscribe
Search
Total
179 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2015-2177 | 1 Siemens | 2 Simatic S7-300 Cpu, Simatic S7-300 Cpu Firmware | 2018-06-02 | 7.8 HIGH | N/A |
| Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus. | |||||
| CVE-2014-5074 | 1 Siemens | 8 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1513-1 Pn Cpu and 5 more | 2018-05-25 | 7.1 HIGH | N/A |
| Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets. | |||||
| CVE-2014-2908 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2018-05-25 | 4.3 MEDIUM | N/A |
| Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
| CVE-2015-5374 | 1 Siemens | 3 Siprotec 4, Siprotec Compact, Siprotec Firmware | 2018-03-23 | 7.8 HIGH | N/A |
| A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. | |||||
| CVE-2000-0964 | 1 Siemens | 1 Hinet Lp | 2017-10-10 | 10.0 HIGH | N/A |
| Buffer overflow in the web administration service for the HiNet LP5100 IP-phone allows remote attackers to cause a denial of service and possibly execute arbitrary commands via a long GET request. | |||||
| CVE-2009-1152 | 1 Siemens | 1 Gigaset Se461 Wimax Router | 2017-09-29 | 7.3 HIGH | N/A |
| Siemens Gigaset SE461 WiMAX router 1.5-BL024.9.6401, and possibly other versions, allows remote attackers to cause a denial of service (device restart and loss of configuration) by connecting to TCP port 53, then closing the connection. | |||||
| CVE-2008-6916 | 2 John Doe, Siemens | 2 Netport Software, Speedstream 5200 | 2017-09-29 | 10.0 HIGH | N/A |
| Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname. | |||||
| CVE-2015-5084 | 1 Siemens | 2 Simatic Wincc Sm\@rtclient, Simatic Wincc Sm\@rtclient Lite | 2017-09-21 | 2.1 LOW | N/A |
| The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors. | |||||
| CVE-2015-7836 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2017-09-15 | 3.3 LOW | N/A |
| Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame. | |||||
| CVE-2014-1698 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2017-08-29 | 5.0 MEDIUM | N/A |
| Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999. | |||||
| CVE-2014-1699 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2017-08-29 | 5.0 MEDIUM | N/A |
| Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999. | |||||
| CVE-2014-1696 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2017-08-29 | 5.0 MEDIUM | N/A |
| Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack. | |||||
| CVE-2014-1697 | 1 Siemens | 1 Simatic Wincc Open Architecture | 2017-08-29 | 7.5 HIGH | N/A |
| The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999. | |||||
| CVE-2013-4911 | 1 Siemens | 1 Wincc | 2017-08-29 | 6.8 MEDIUM | N/A |
| Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | |||||
| CVE-2013-4912 | 1 Siemens | 1 Wincc | 2017-08-29 | 5.8 MEDIUM | N/A |
| Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product. | |||||
| CVE-2011-4876 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2017-08-29 | 9.3 HIGH | N/A |
| Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. | |||||
| CVE-2011-4875 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2017-08-29 | 9.3 HIGH | N/A |
| Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings. | |||||
| CVE-2011-3321 | 1 Siemens | 2 Simatic Wincc Flexible Runtime, Simatic Wincc Runtime | 2017-08-29 | 9.3 HIGH | N/A |
| Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. | |||||
| CVE-2011-4055 | 1 Siemens | 1 Tecnomatix Factorylink | 2017-08-29 | 9.3 HIGH | N/A |
| Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL. | |||||
| CVE-2011-4878 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2017-08-29 | 7.8 HIGH | N/A |
| Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. | |||||
| CVE-2011-4879 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2017-08-29 | 8.5 HIGH | N/A |
| miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. | |||||
| CVE-2011-4877 | 1 Siemens | 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more | 2017-08-29 | 7.1 HIGH | N/A |
| HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. | |||||
| CVE-2010-2772 | 1 Siemens | 2 Simatic Pcs 7, Simatic Wincc | 2017-08-17 | 6.9 MEDIUM | N/A |
| Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. | |||||
| CVE-2008-3972 | 2 Opensc-project, Siemens | 2 Opensc, Cardos | 2017-08-08 | 6.6 MEDIUM | N/A |
| pkcs15-tool in OpenSC before 0.11.6 does not apply security updates to a smart card unless the card's label matches the "OpenSC" string, which might allow physically proximate attackers to exploit vulnerabilities that the card owner expected were patched, as demonstrated by exploitation of CVE-2008-2235. | |||||
| CVE-2008-2235 | 2 Opensc-project, Siemens | 2 Opensc, Cardos | 2017-08-08 | 4.9 MEDIUM | N/A |
| OpenSC before 0.11.5 uses weak permissions (ADMIN file control information of 00) for the 5015 directory on smart cards and USB crypto tokens running Siemens CardOS M4, which allows physically proximate attackers to change the PIN. | |||||
| CVE-2003-1464 | 1 Siemens | 2 M45, S45 | 2017-07-29 | 7.8 HIGH | N/A |
| Buffer overflow in Siemens 45 series mobile phones allows remote attackers to cause a denial of service (disconnect and unavailable inbox) via a Short Message Service (SMS) message with a long image name. | |||||
| CVE-2004-2626 | 1 Siemens | 1 S55 | 2017-07-20 | 3.7 LOW | N/A |
| GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message. | |||||
| CVE-2005-2424 | 1 Siemens | 1 Santis 50 | 2017-07-11 | 7.5 HIGH | N/A |
| The management interface for Siemens SANTIS 50 running firmware 4.2.8.0, and possibly other products including Ericsson HN294dp and Dynalink RTA300W, allows remote attackers to access the Telnet port without authentication via certain packets to the web interface that cause the interface to freeze. | |||||
| CVE-2015-5698 | 1 Siemens | 2 Simatic S7 1200 Cpu, Simatic S7 1200 Cpu Firmware | 2016-12-22 | 7.5 HIGH | N/A |
| Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. | |||||
| CVE-2015-6675 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2016-12-22 | 4.3 MEDIUM | N/A |
| Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic. | |||||
| CVE-2015-4174 | 1 Siemens | 1 Climatix Bacnet\/ip | 2016-12-07 | 4.3 MEDIUM | N/A |
| Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
| CVE-2015-1358 | 1 Siemens | 1 Wincc | 2016-11-30 | 5.0 MEDIUM | N/A |
| The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack. | |||||
| CVE-2015-2823 | 1 Siemens | 6 Simatic Hmi Basic Panels Generation 1, Simatic Hmi Basic Panels Generation 2, Simatic Hmi Comfort Panels and 3 more | 2016-11-28 | 6.8 MEDIUM | N/A |
| Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. | |||||
| CVE-2015-2822 | 1 Siemens | 1 Wincc | 2016-11-28 | 4.3 MEDIUM | N/A |
| Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. | |||||
| CVE-2015-1601 | 1 Siemens | 1 Simatic Step 7 | 2016-11-28 | 6.8 MEDIUM | N/A |
| Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors. | |||||
| CVE-2001-0411 | 1 Siemens | 1 Reliant Unix | 2016-10-18 | 5.0 MEDIUM | N/A |
| Reliant Unix 5.44 and earlier allows remote attackers to cause a denial of service via an ICMP port unreachable packet, which causes Reliant to drop all connections to the source address of the packet. | |||||
| CVE-2015-1594 | 1 Siemens | 5 Simatic Cfc, Simatic Prosave, Simatic Step 7 and 2 more | 2016-08-24 | 6.9 MEDIUM | N/A |
| Untrusted search path vulnerability in Siemens SIMATIC ProSave before 13 SP1; SIMATIC CFC before 8.0 SP4 Upd9 and 8.1 before Upd1; SIMATIC STEP 7 before 5.5 SP1 HF2, 5.5 SP2 before HF7, 5.5 SP3, and 5.5 SP4 before HF4; SIMOTION Scout before 4.4; and STARTER before 4.4 HF3 allows local users to gain privileges via a Trojan horse application file. | |||||
| CVE-2014-5233 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2015-11-13 | 1.9 LOW | N/A |
| The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism. | |||||
| CVE-2014-5231 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2015-11-13 | 2.1 LOW | N/A |
| The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors. | |||||
| CVE-2014-5232 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2015-11-13 | 1.9 LOW | N/A |
| The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state. | |||||
| CVE-2015-5717 | 1 Siemens | 1 Compas | 2015-11-04 | 5.8 MEDIUM | N/A |
| The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. | |||||
| CVE-2014-2732 | 1 Siemens | 1 Sinema Server | 2015-10-08 | 5.0 MEDIUM | N/A |
| Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80. | |||||
| CVE-2015-5386 | 1 Siemens | 2 Sicam Mic, Sicam Mic Firmware | 2015-07-17 | 9.3 HIGH | N/A |
| Siemens SICAM MIC devices with firmware before 2404 allow remote attackers to bypass authentication and obtain administrative access via unspecified HTTP requests. | |||||
| CVE-2015-1595 | 1 Siemens | 1 Spcanywhere | 2015-07-15 | 4.3 MEDIUM | N/A |
| The Siemens SPCanywhere application for Android and iOS does not use encryption during lookups of system ID to IP address mappings, which allows man-in-the-middle attackers to discover alarm IP addresses and spoof servers by intercepting the client-server data stream. | |||||
| CVE-2015-3610 | 1 Siemens | 1 Homecontrol For Room Automation | 2015-05-07 | 5.4 MEDIUM | N/A |
| The Siemens HomeControl for Room Automation application before 2.0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information or modify data via a crafted certificate. | |||||
| CVE-2015-1602 | 1 Siemens | 1 Simatic Step 7 | 2015-04-23 | 2.1 LOW | N/A |
| Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files. | |||||
| CVE-2015-1599 | 1 Siemens | 1 Spcanywhere | 2015-03-09 | 2.1 LOW | N/A |
| The Siemens SPCanywhere application for iOS allows physically proximate attackers to bypass intended access restrictions by leveraging a filesystem architectural error. | |||||
| CVE-2015-1596 | 1 Siemens | 1 Spcanywhere | 2015-03-09 | 5.8 MEDIUM | N/A |
| The Siemens SPCanywhere application for Android and iOS does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. | |||||
| CVE-2015-1598 | 1 Siemens | 1 Spcanywhere | 2015-03-09 | 2.1 LOW | N/A |
| The Siemens SPCanywhere application for Android does not properly store application passwords, which allows physically proximate attackers to obtain sensitive information by examining the device filesystem. | |||||
| CVE-2015-1597 | 1 Siemens | 1 Spcanywhere | 2015-03-09 | 6.8 MEDIUM | N/A |
| The Siemens SPCanywhere application for Android does not use encryption during the loading of code, which allows man-in-the-middle attackers to execute arbitrary code by modifying the client-server data stream. | |||||