Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Filtered by product Simatic S7-400 Pn\/dp V7
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-25622 1 Siemens 23 Simatic Cfu Diq, Simatic Cfu Diq Firmware, Simatic Cfu Pa and 20 more 2022-07-12 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC ET200AL IM157-1 PN (All versions), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 MF HF (All versions), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (All versions >= V5.1.1), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (All versions >= V5.1.1), SIMATIC PN/MF Coupler (All versions), SIMATIC PN/PN Coupler (All versions >= 4.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions), SINAMICS DCM (All versions with Ethernet interface), SINAMICS G110M (All versions with Ethernet interface), SINAMICS G115D (All versions with Ethernet interface), SINAMICS G120 (incl. SIPLUS variants) (All versions with Ethernet interface), SINAMICS G130 (All versions), SINAMICS G150 (All versions), SINAMICS S110 (All versions with Ethernet interface), SINAMICS S120 (incl. SIPLUS variants) (All versions), SINAMICS S150 (All versions), SINAMICS S210 (All versions), SINAMICS V90 (All versions with Ethernet interface), SIPLUS HCS4200 CIM4210 (All versions), SIPLUS HCS4200 CIM4210C (All versions), SIPLUS HCS4300 CIM4310 (All versions), SIPLUS NET PN/PN Coupler (All versions >= 4.2). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
CVE-2018-16557 1 Siemens 8 Simatic S7-400, Simatic S7-400 Firmware, Simatic S7-400 Pn\/dp V7 and 5 more 2020-09-18 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400H V4.5 and below (All versions), SIMATIC S7-400H V6 (All versions < V6.0.9), SIMATIC S7-410 (All versions < V8.2.1). Sending of specially crafted packets to port 102/tcp via Ethernet interface via PROFIBUS or Multi Point Interfaces (MPI) could cause a Denial-of-Service condition on affected devices. Flashing with a firmware image may be required to recover the CPU. Successful exploitation requires an attacker to have network access to port 102/tcp via Ethernet interface or to be able to send messages via PROFIBUS or Multi Point Interfaces (MPI) to the device. No user interaction is required. If no access protection is configured, no privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-16556 1 Siemens 10 Simatic S7-400, Simatic S7-400 Firmware, Simatic S7-400 Pn\/dp V7 and 7 more 2019-05-14 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-400 (incl. F) V6 and below (All versions), SIMATIC S7-400 PN/DP V7 (incl. F) (All versions), SIMATIC S7-400H V4.5 and below (All versions), SIMATIC S7-400H V6 (All versions < V6.0.9), SIMATIC S7-410 (All versions < V8.2.1). Specially crafted packets sent to port 102/tcp via Ethernet interface, via PROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected devices to go into defect mode. Manual reboot is required to resume normal operation. Successful exploitation requires an attacker to be able to send specially crafted packets to port 102/tcp via Ethernet interface, via PROFIBUS or Multi Point Interfaces (MPI). No user interaction and no user privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.