Filtered by vendor Siemens
Subscribe
Filtered by product En100 Ethernet Module Iec 104 Firmware
Subscribe
Search
Total
4 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-30938 | 1 Siemens | 6 En100 Ethernet Module, En100 Ethernet Module Dnp3 Ip Firmware, En100 Ethernet Module Iec 104 Firmware and 3 more | 2022-07-27 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition | |||||
| CVE-2022-30937 | 1 Siemens | 6 En100 Ethernet Module, En100 Ethernet Module Dnp3 Firmware, En100 Ethernet Module Iec 104 Firmware and 3 more | 2022-06-22 | 7.8 HIGH | 7.5 HIGH |
| A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition. | |||||
| CVE-2018-4840 | 1 Siemens | 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Siemens DIGSI 4 (All versions < V4.92), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 104 variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords. | |||||
| CVE-2018-4838 | 1 Siemens | 10 En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware, En100 Ethernet Module Iec 104 and 7 more | 2019-10-03 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities. | |||||