Vulnerabilities (CVE)

CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-36295 1 Dell 9 Emc Unity Operating Environment, Vnx5200, Vnx5400 and 6 more 2022-01-31 9.0 HIGH 7.2 HIGH
Dell VNX2 OE for File versions 8.1.21.266 and earlier, contain an authenticated remote code execution vulnerability. A remote malicious user with privileges may exploit this vulnerability to execute commands on the system.
CVE-2019-10953 5 Abb, Phoenixcontact, Schneider-electric and 2 more 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more 2022-01-31 5.0 MEDIUM 7.5 HIGH
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
CVE-2018-7821 1 Schneider-electric 3 Modicon M221, Modicon M221 Firmware, Somachine Basic 2022-01-31 5.0 MEDIUM 7.5 HIGH
An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated.
CVE-2018-7798 1 Schneider-electric 2 Modicon M221, Somachine Basic 2022-01-31 6.4 MEDIUM 8.2 HIGH
A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device.
CVE-2021-34868 1 Parallels 1 Parallels 2022-01-31 7.2 HIGH 8.8 HIGH
This vulnerability allows local attackers to escalate privileges on affected installations of Parallels Desktop 16.1.3-49160. An attacker must first obtain the ability to execute low-privileged code on the target guest system in order to exploit this vulnerability. The specific flaw exists within the Toolgate component. The issue results from the lack of proper validation of user-supplied data, which can result in an uncontrolled memory allocation. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of the hypervisor. Was ZDI-CAN-13712.
CVE-2021-34867 1 Parallels 1 Parallels 2022-01-31 7.2 HIGH 8.2 HIGH
This vulnerability allows local attackers to escalate privileges on affected installations of Parallels Desktop 16.1.3-49160. An attacker must first obtain the ability to execute high-privileged code on the target guest system in order to exploit this vulnerability. The specific flaw exists within the Toolgate component. The issue results from the lack of proper validation of user-supplied data, which can result in an uncontrolled memory allocation. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of the hypervisor. Was ZDI-CAN-13672.
CVE-2021-22766 1 Schneider-electric 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more 2022-01-31 5.0 MEDIUM 7.5 HIGH
** UNSUPPORTED WHEN ASSIGNED ** A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet.
CVE-2021-46086 1 Mindskip 1 Xzs-mysql 2022-01-31 5.0 MEDIUM 7.5 HIGH
xzs-mysql >= t3.4.0 is vulnerable to Insecure Permissions. The front end of this open source system is an online examination system. There is an unsafe vulnerability in the functional method of submitting examination papers. An attacker can use burpuite to modify parameters in the packet to destroy real data.
CVE-2020-7524 1 Schneider-electric 2 Modicon M218, Modicon M218 Firmware 2022-01-31 5.0 MEDIUM 7.5 HIGH
Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal.
CVE-2020-7502 1 Schneider-electric 2 Modicon M218, Modicon M218 Firmware 2022-01-31 5.0 MEDIUM 7.5 HIGH
A CWE-787: Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (Firmware version 4.3 and prior), which may cause a Denial of Service when specific TCP/IP crafted packets are sent to the Modicon M218 Logic Controller.
CVE-2020-7572 1 Schneider-electric 1 Webreports 2022-01-31 6.5 MEDIUM 8.8 HIGH
A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser.
CVE-2020-7569 1 Schneider-electric 1 Webreports 2022-01-31 6.5 MEDIUM 8.8 HIGH
A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.
CVE-2021-22777 1 Schneider-electric 1 Sosafe Configurable 2022-01-31 6.8 MEDIUM 7.8 HIGH
A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file.
CVE-2020-7501 1 Schneider-electric 1 Vijeo Designer 2022-01-31 6.5 MEDIUM 8.8 HIGH
A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer.
CVE-2020-7490 1 Schneider-electric 1 Vijeo Designer 2022-01-31 6.9 MEDIUM 7.8 HIGH
A CWE-426: Untrusted Search Path vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 15 and prior) and Vijeo Designer (V6.9 SP9 and prior), which could cause arbitrary code execution on the system running Vijeo Basic when a malicious DLL library is loaded by the Product.
CVE-2018-7783 1 Schneider-electric 1 Somachine Basic 2022-01-31 5.0 MEDIUM 7.5 HIGH
Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is triggered when input passed to the xml parser is not sanitized while parsing the xml project/template file.
CVE-2017-7965 1 Schneider-electric 1 Somachine Hvac 2022-01-31 4.6 MEDIUM 7.3 HIGH
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
CVE-2016-2290 1 Schneider-electric 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more 2022-01-31 6.8 MEDIUM 8.8 HIGH
Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors.
CVE-2021-43863 1 Nextcloud 1 Nextcloud 2022-01-31 5.0 MEDIUM 7.5 HIGH
The Nextcloud Android app is the Android client for Nextcloud, a self-hosted productivity platform. The Nextcloud Android app uses content providers to manage its data. Prior to version 3.18.1, the providers `FileContentProvider` and `DiskLruImageCacheFileProvider` have security issues (an SQL injection, and an insufficient permission control, respectively) that allow malicious apps in the same device to access Nextcloud's data bypassing the permission control system. Users should upgrade to version 3.18.1 to receive a patch. There are no known workarounds aside from upgrading.
CVE-2021-22705 1 Schneider-electric 9 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 6 more 2022-01-31 4.6 MEDIUM 7.8 HIGH
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert
CVE-2021-22698 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2022-01-31 6.8 MEDIUM 7.8 HIGH
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
CVE-2021-22697 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2022-01-31 6.8 MEDIUM 7.8 HIGH
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
CVE-2020-7560 1 Schneider-electric 2 Ecostruxure Control Expert, Unity Pro 2022-01-31 6.8 MEDIUM 8.6 HIGH
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software.
CVE-2020-7544 1 Schneider-electric 1 Operator Terminal Expert Runtime 2022-01-31 7.2 HIGH 7.8 HIGH
A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert.
CVE-2020-7538 1 Schneider-electric 1 Ecostruxure Control Expert 2022-01-31 5.0 MEDIUM 7.5 HIGH
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
CVE-2020-28213 1 Schneider-electric 1 Ecostruxure Control Expert 2022-01-31 6.5 MEDIUM 8.8 HIGH
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
CVE-2020-28211 1 Schneider-electric 1 Ecostruxure Control Expert 2022-01-31 4.6 MEDIUM 7.8 HIGH
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.
CVE-2020-28209 2 Microsoft, Schneider-electric 2 Windows, Enterprise Server Installer 2022-01-31 4.4 MEDIUM 7.0 HIGH
A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administrator privileges so the vulnerability is only valid if the application has been installed on a non-secure location.
CVE-2020-10626 2 Fazecast, Schneider-electric 2 Jserialcomm, Ecostruxure It Gateway 2022-01-31 6.9 MEDIUM 7.8 HIGH
In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code.
CVE-2019-6855 1 Schneider-electric 44 Ecostruxure Control Expert, Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware and 41 more 2022-01-31 7.5 HIGH 7.3 HIGH
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.
CVE-2019-3843 4 Canonical, Fedoraproject, Netapp and 1 more 8 Ubuntu Linux, Fedora, Cn1610 and 5 more 2022-01-31 4.6 MEDIUM 7.8 HIGH
It was discovered that a systemd service that uses DynamicUser property can create a SUID/SGID binary that would be allowed to run as the transient service UID/GID even after the service is terminated. A local attacker may use this flaw to access resources that will be owned by a potentially different service in the future, when the UID/GID will be recycled.
CVE-2019-3844 3 Canonical, Netapp, Systemd Project 7 Ubuntu Linux, Cn1610, Cn1610 Firmware and 4 more 2022-01-31 4.6 MEDIUM 7.8 HIGH
It was discovered that a systemd service that uses DynamicUser property can get new privileges through the execution of SUID binaries, which would allow to create binaries owned by the service transient group with the setgid bit set. A local attacker may use this flaw to access resources that will be owned by a potentially different service in the future, when the GID will be recycled.
CVE-2019-3842 4 Debian, Fedoraproject, Redhat and 1 more 4 Debian Linux, Fedora, Enterprise Linux and 1 more 2022-01-31 4.4 MEDIUM 7.0 HIGH
In systemd before v242-rc4, it was discovered that pam_systemd does not properly sanitize the environment before using the XDG_SEAT variable. It is possible for an attacker, in some particular configurations, to set a XDG_SEAT environment variable which allows for commands to be checked against polkit policies using the "allow_active" element rather than "allow_any".
CVE-2018-16865 5 Canonical, Debian, Oracle and 2 more 11 Ubuntu Linux, Debian Linux, Communications Session Border Controller and 8 more 2022-01-31 4.6 MEDIUM 7.8 HIGH
An allocation of memory without limits, that could result in the stack clashing with another memory region, was discovered in systemd-journald when many entries are sent to the journal socket. A local attacker, or a remote one if systemd-journal-remote is used, may use this flaw to crash systemd-journald or execute code with journald privileges. Versions through v240 are vulnerable.
CVE-2018-16864 5 Canonical, Debian, Oracle and 2 more 11 Ubuntu Linux, Debian Linux, Communications Session Border Controller and 8 more 2022-01-31 4.6 MEDIUM 7.8 HIGH
An allocation of memory without limits, that could result in the stack clashing with another memory region, was discovered in systemd-journald when a program with long command line arguments calls syslog. A local attacker may use this flaw to crash systemd-journald or escalate his privileges. Versions through v240 are vulnerable.
CVE-2018-15688 4 Canonical, Debian, Redhat and 1 more 9 Ubuntu Linux, Debian Linux, Enterprise Linux Desktop and 6 more 2022-01-31 5.8 MEDIUM 8.8 HIGH
A buffer overflow vulnerability in the dhcp6 client of systemd allows a malicious dhcp6 server to overwrite heap memory in systemd-networkd. Affected releases are systemd: versions up to and including 239.
CVE-2018-15687 2 Canonical, Systemd Project 2 Ubuntu Linux, Systemd 2022-01-31 6.9 MEDIUM 7.0 HIGH
A race condition in chown_one() of systemd allows an attacker to cause systemd to set arbitrary permissions on arbitrary files. Affected releases are systemd versions up to and including 239.
CVE-2018-15686 4 Canonical, Debian, Oracle and 1 more 4 Ubuntu Linux, Debian Linux, Communications Cloud Native Core Network Function Cloud Native Environment and 1 more 2022-01-31 7.2 HIGH 7.8 HIGH
A vulnerability in unit_deserialize of systemd allows an attacker to supply arbitrary state across systemd re-execution via NotifyAccess. This can be used to improperly influence systemd execution and possibly lead to root privilege escalation. Affected releases are systemd versions up to and including 239.
CVE-2018-6954 3 Canonical, Opensuse, Systemd Project 3 Ubuntu Linux, Leap, Systemd 2022-01-31 7.2 HIGH 7.8 HIGH
systemd-tmpfiles in systemd through 237 mishandles symlinks present in non-terminal path components, which allows local users to obtain ownership of arbitrary files via vectors involving creation of a directory and a file under that directory, and later replacing that directory with a symlink. This occurs even if the fs.protected_symlinks sysctl is turned on.
CVE-2017-18078 3 Debian, Opensuse, Systemd Project 3 Debian Linux, Leap, Systemd 2022-01-31 4.6 MEDIUM 7.8 HIGH
systemd-tmpfiles in systemd before 237 attempts to support ownership/permission changes on hardlinked files even if the fs.protected_hardlinks sysctl is turned off, which allows local users to bypass intended access restrictions via vectors involving a hard link to a file for which the user lacks write access, as demonstrated by changing the ownership of the /etc/passwd file.
CVE-2017-9445 1 Systemd Project 1 Systemd 2022-01-31 5.0 MEDIUM 7.5 HIGH
In systemd through 233, certain sizes passed to dns_packet_new in systemd-resolved can cause it to allocate a buffer that's too small. A malicious DNS server can exploit this via a response with a specially crafted TCP payload to trick systemd-resolved into allocating a buffer that's too small, and subsequently write arbitrary data beyond the end of it.
CVE-2017-9217 1 Systemd Project 1 Systemd 2022-01-31 5.0 MEDIUM 7.5 HIGH
systemd-resolved through 233 allows remote attackers to cause a denial of service (daemon crash) via a crafted DNS response with an empty question section.
CVE-2015-8539 3 Canonical, Linux, Suse 3 Ubuntu Linux, Linux Kernel, Linux Enterprise Real Time Extension 2022-01-31 7.2 HIGH 7.8 HIGH
The KEYS subsystem in the Linux kernel before 4.4 allows local users to gain privileges or cause a denial of service (BUG) via crafted keyctl commands that negatively instantiate a key, related to security/keys/encrypted-keys/encrypted.c, security/keys/trusted.c, and security/keys/user_defined.c.
CVE-2016-10197 2 Debian, Libevent Project 2 Debian Linux, Libevent 2022-01-31 5.0 MEDIUM 7.5 HIGH
The search_make_new function in evdns.c in libevent before 2.1.6-beta allows attackers to cause a denial of service (out-of-bounds read) via an empty hostname.
CVE-2016-10196 3 Debian, Libevent Project, Mozilla 5 Debian Linux, Libevent, Firefox and 2 more 2022-01-31 5.0 MEDIUM 7.5 HIGH
Stack-based buffer overflow in the evutil_parse_sockaddr_port function in evutil.c in libevent before 2.1.6-beta allows attackers to cause a denial of service (segmentation fault) via vectors involving a long string in brackets in the ip_as_string argument.
CVE-2016-5384 4 Canonical, Debian, Fedoraproject and 1 more 4 Ubuntu Linux, Debian Linux, Fedora and 1 more 2022-01-31 4.6 MEDIUM 7.8 HIGH
fontconfig before 2.12.1 does not validate offsets, which allows local users to trigger arbitrary free calls and consequently conduct double free attacks and execute arbitrary code via a crafted cache file.
CVE-2021-39031 1 Ibm 1 Websphere Application Server 2022-01-28 6.5 MEDIUM 8.8 HIGH
IBM WebSphere Application Server - Liberty 17.0.0.3 through 22.0.0.1 could allow a remote authenticated attacker to conduct an LDAP injection. By using a specially crafted request, an attacker could exploit this vulnerability and could result in in granting permission to unauthorized resources. IBM X-Force ID: 213875.
CVE-2021-38177 1 Sap 1 Commoncryptolib 2022-01-28 5.0 MEDIUM 7.5 HIGH
SAP CommonCryptoLib version 8.5.38 or lower is vulnerable to null pointer dereference vulnerability when an unauthenticated attacker sends crafted malicious data in the HTTP requests over the network, this causes the SAP application to crash and has high impact on the availability of the SAP system.
CVE-2021-45844 1 Freecadweb 1 Freecad 2022-01-28 7.6 HIGH 7.8 HIGH
Improper sanitization in the invocation of ODA File Converter from FreeCAD 0.19 allows an attacker to inject OS commands via a crafted filename.
CVE-2022-21711 1 Elfspirit Project 1 Elfspirit 2022-01-28 5.8 MEDIUM 7.1 HIGH
elfspirit is an ELF static analysis and injection framework that parses, manipulates, and camouflages ELF files. When analyzing the ELF file format in versions prior to 1.1, there is an out-of-bounds read bug, which can lead to application crashes or information leakage. By constructing a special format ELF file, the information of any address can be leaked. elfspirit version 1.1 contains a patch for this issue.