Filtered by vendor Ge
Subscribe
Search
Total
19 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-5908 | 4 Ge, Ptc, Rockwellautomation and 1 more | 8 Industrial Gateway Server, Keepserverex, Opc-aggregator and 5 more | 2023-12-06 | N/A | 9.1 CRITICAL |
| KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information. | |||||
| CVE-2023-3463 | 1 Ge | 1 Cimplicity | 2023-07-28 | N/A | 9.8 CRITICAL |
| All versions of GE Digital CIMPLICITY that are not adhering to SDG guidance and accepting documents from untrusted sources are vulnerable to memory corruption issues due to insufficient input validation, including issues such as out-of-bounds reads and writes, use-after-free, stack-based buffer overflows, uninitialized pointers, and a heap-based buffer overflow. Successful exploitation could allow an attacker to execute arbitrary code. | |||||
| CVE-2018-5473 | 1 Ge | 2 D60 Line Distance Relay, D60 Line Distance Relay Firmware | 2021-08-18 | 10.0 HIGH | 9.8 CRITICAL |
| An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote attacker to execute arbitrary code on the device. | |||||
| CVE-2021-27440 | 1 Ge | 2 Reason Dr60, Reason Dr60 Firmware | 2021-03-30 | 7.5 HIGH | 9.8 CRITICAL |
| The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1). | |||||
| CVE-2016-2310 | 1 Ge | 8 Multilink Firmware, Multilink Ml1200, Multilink Ml1600 and 5 more | 2021-03-29 | 10.0 HIGH | 9.8 CRITICAL |
| General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface. | |||||
| CVE-2021-27452 | 1 Ge | 2 Mu320e, Mu320e Firmware | 2021-03-29 | 10.0 HIGH | 9.8 CRITICAL |
| The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1). | |||||
| CVE-2020-27265 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2021-01-21 | 7.5 HIGH | 9.8 CRITICAL |
| KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. | |||||
| CVE-2020-27267 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2021-01-21 | 6.4 MEDIUM | 9.1 CRITICAL |
| KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | |||||
| CVE-2020-27263 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2021-01-21 | 6.4 MEDIUM | 9.1 CRITICAL |
| KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | |||||
| CVE-2018-5475 | 1 Ge | 2 D60 Line Distance Relay, D60 Line Distance Relay Firmware | 2020-09-18 | 7.5 HIGH | 9.8 CRITICAL |
| A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution. | |||||
| CVE-2020-12017 | 1 Ge | 6 Rt430, Rt430 Firmware, Rt431 and 3 more | 2020-06-08 | 9.0 HIGH | 9.8 CRITICAL |
| GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system. | |||||
| CVE-2018-10611 | 1 Ge | 1 Mds Pulsenet | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services. | |||||
| CVE-2017-7905 | 1 Ge | 20 Multilin Sr 369 Motor Protection Relay, Multilin Sr 369 Motor Protection Relay Firmware, Multilin Sr 469 Motor Protection Relay and 17 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. | |||||
| CVE-2017-14008 | 1 Ge | 1 Centricity Pacs Ra1000 | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices. | |||||
| CVE-2017-14006 | 1 Ge | 1 Xeleris | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices. | |||||
| CVE-2017-14004 | 1 Ge | 1 Gemnet License Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices. | |||||
| CVE-2017-14002 | 1 Ge | 2 Infinia Hawkeye 4, Infinia Hawkeye 4 Firmware | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices. | |||||
| CVE-2018-15362 | 1 Ge | 1 Cimplicity | 2019-02-06 | 6.4 MEDIUM | 9.1 CRITICAL |
| XXE in GE Proficy Cimplicity GDS versions 9.0 R2, 9.5, 10.0 | |||||
| CVE-2016-5788 | 1 Ge | 4 Bently Nevada 3500\/22m Serial, Bently Nevada 3500\/22m Serial Firmware, Bently Nevada 3500\/22m Usb and 1 more | 2016-11-28 | 10.0 HIGH | 10.0 CRITICAL |
| General Electric (GE) Bently Nevada 3500/22M USB with firmware before 5.0 and Bently Nevada 3500/22M Serial have open ports, which makes it easier for remote attackers to obtain privileged access via unspecified vectors. | |||||