Vulnerabilities (CVE)

CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-22413 1 Ibm 1 Robotic Process Automation 2022-05-21 7.5 HIGH 9.8 CRITICAL
IBM Robotic Process Automation 21.0.0, 21.0.1, and 21.0.2 is vulnerable to SQL injection. A remote attacker could send specially crafted SQL statements, which could allow the attacker to view, add, modify or delete information in the back-end database. IBM X-Force ID: 223022.
CVE-2022-29307 1 Ionizecms 1 Ionize 2022-05-21 7.5 HIGH 9.8 CRITICAL
IonizeCMS v1.0.8.1 was discovered to contain a command injection vulnerability via the function copy_lang_content in application/models/lang_model.php.
CVE-2021-28794 1 Shellcheck Project 1 Shellcheck 2022-05-20 7.5 HIGH 9.8 CRITICAL
The unofficial ShellCheck extension before 0.13.4 for Visual Studio Code mishandles shellcheck.executablePath.
CVE-2021-28967 1 Microsoft 1 Visual Studio Code 2022-05-20 7.5 HIGH 9.8 CRITICAL
The unofficial MATLAB extension before 2.0.1 for Visual Studio Code allows attackers to execute arbitrary code via a crafted workspace because of lint configuration settings.
CVE-2021-28955 1 Git-bug Project 1 Git-bug 2022-05-20 7.5 HIGH 9.8 CRITICAL
git-bug before 0.7.2 has an Uncontrolled Search Path Element. It will execute git.bat from the current directory in certain PATH situations (most often seen on Windows).
CVE-2022-30592 1 Litespeedtech 1 Lsquic 2022-05-20 7.5 HIGH 9.8 CRITICAL
liblsquic/lsquic_qenc_hdl.c in LiteSpeed QUIC (aka LSQUIC) before 3.1.0 mishandles MAX_TABLE_CAPACITY.
CVE-2022-29596 1 Microstrategy 1 Enterprise Manager 2022-05-20 7.5 HIGH 9.8 CRITICAL
MicroStrategy Enterprise Manager 2022 allows authentication bypass by triggering a login failure and then entering the Uid=/../../../../../../../../../../../windows/win.ini%00.jpg&Pwd=_any_password_&ConnMode=1&3054=Login substring for directory traversal.
CVE-2022-30450 1 Waimairencms Project 1 Waimairencms 2022-05-20 7.5 HIGH 9.8 CRITICAL
A Remote Code Execution (RCE) vulnerability exists in waimairen 9.1 via wx.php
CVE-2022-30449 1 Hospital Management System Project 1 Hospital Management System 2022-05-20 7.5 HIGH 9.8 CRITICAL
Hospital Management System in PHP with Source Code (HMS) 1.0 was discovered to contain a SQL injection vulnerability via the editid parameter in room.php.
CVE-2022-30448 1 Hospital Management System Project 1 Hospital Management System 2022-05-20 7.5 HIGH 9.8 CRITICAL
Hospital Management System in PHP with Source Code (HMS) 1.0 was discovered to contain a File upload vulnerability in treatmentrecord.php.
CVE-2022-30063 1 Ftcms 1 Ftcms 2022-05-20 7.5 HIGH 9.8 CRITICAL
ftcms <=2.1 was discovered to be vulnerable to code execution attacks .
CVE-2022-30453 1 Shopwind 1 Shopwind 2022-05-20 7.5 HIGH 9.8 CRITICAL
ShopWind <= 3.4.2 has a RCE vulnerability in Database.php
CVE-2022-30048 1 Mingsoft 1 Mcms 2022-05-20 7.5 HIGH 9.8 CRITICAL
Mingsoft MCMS 5.2.7 was discovered to contain a SQL injection vulnerability in /mdiy/dict/list URI via orderBy parameter.
CVE-2022-30047 1 Mingsoft 1 Mcms 2022-05-20 7.5 HIGH 9.8 CRITICAL
Mingsoft MCMS v5.2.7 was discovered to contain a SQL injection vulnerability in /mdiy/dict/listExcludeApp URI via orderBy parameter.
CVE-2022-29898 1 Phoenixcontact 6 Rad-ism-900-en-bd, Rad-ism-900-en-bd-bus, Rad-ism-900-en-bd-bus Firmware and 3 more 2022-05-20 9.0 HIGH 9.1 CRITICAL
On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.
CVE-2022-29897 1 Phoenixcontact 6 Rad-ism-900-en-bd, Rad-ism-900-en-bd-bus, Rad-ism-900-en-bd-bus Firmware and 3 more 2022-05-20 9.0 HIGH 9.1 CRITICAL
On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the traceroute utility integrated in the WebUI to execute arbitrary code with root privileges on the OS due to an improper input validation in all versions of the firmware.
CVE-2022-24042 1 Siemens 8 Desigo Dxr2, Desigo Dxr2 Firmware, Desigo Pxc3 and 5 more 2022-05-20 6.4 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application returns an AuthToken that does not expire at the defined auto logoff delay timeout. An attacker could be able to capture this token and re-use old session credentials or session IDs for authorization.
CVE-2022-24039 1 Siemens 4 Desigo Pxc4, Desigo Pxc4 Firmware, Desigo Pxc5 and 1 more 2022-05-20 8.5 HIGH 9.0 CRITICAL
A vulnerability has been identified in Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The “addCell” JavaScript function fails to properly sanitize user-controllable input before including it into the generated XML body of the XLS report document, such that it is possible to inject arbitrary content (e.g., XML tags) into the generated file. An attacker with restricted privileges, by poisoning any of the content used to generate XLS reports, could be able to leverage the application to deliver malicious files against higher-privileged users and obtain Remote Code Execution (RCE) against the administrator’s workstation.
CVE-2021-40358 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2022-05-20 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
CVE-2021-31890 1 Siemens 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more 2022-05-20 6.4 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)
CVE-2021-31889 1 Siemens 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more 2022-05-20 6.4 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)
CVE-2021-31886 1 Siemens 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more 2022-05-20 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
CVE-2021-31884 1 Siemens 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more 2022-05-20 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The DHCP client application assumes that the data supplied with the “Hostname” DHCP option is NULL terminated. In cases when global hostname variable is not defined, this may lead to Out-of-bound reads, writes, and Denial-of-service conditions. (FSMD-2021-0014)
CVE-2021-31346 1 Siemens 17 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 14 more 2022-05-20 6.4 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
CVE-2021-31345 1 Siemens 16 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 13 more 2022-05-20 6.4 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
CVE-2022-27007 1 F5 1 Njs 2022-05-19 7.5 HIGH 9.8 CRITICAL
nginx njs 0.7.2 is affected suffers from Use-after-free in njs_function_frame_alloc() when it try to invoke from a restored frame saved with njs_function_frame_save().
CVE-2022-22774 1 Tibco 2 Managed File Transfer Command Center, Managed File Transfer Internet Server 2022-05-19 6.4 MEDIUM 9.1 CRITICAL
The DOM XML parser and SAX XML parser components of TIBCO Software Inc.'s TIBCO Managed File Transfer Command Center, TIBCO Managed File Transfer Command Center, TIBCO Managed File Transfer Internet Server, and TIBCO Managed File Transfer Internet Server contains an easily exploitable vulnerability that allows an unauthenticated attacker with network access to execute XML External Entity (XXE) attacks on the affected system. Affected releases are TIBCO Software Inc.'s TIBCO Managed File Transfer Command Center: versions 8.3.1 and below, TIBCO Managed File Transfer Command Center: versions 8.4.0 and 8.4.1, TIBCO Managed File Transfer Internet Server: versions 8.3.1 and below, and TIBCO Managed File Transfer Internet Server: versions 8.4.0 and 8.4.1.
CVE-2021-38969 1 Ibm 1 Spectrum Virtualize 2022-05-19 5.0 MEDIUM 9.8 CRITICAL
IBM Spectrum Virtualize 8.2, 8.3, and 8.4 could allow an attacker to allow unauthorized access due to the reuse of support generated credentials. IBM X-Force ID: 212609.
CVE-2022-29751 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/classes/Master.php?f=delete_client.
CVE-2022-29750 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/classes/Master.php?f=delete_service.
CVE-2022-29749 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/classes/Master.php?f=delete_invoice.
CVE-2022-29748 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via \cms\admin?page=client/manage_client&id=.
CVE-2022-29747 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/admin/?page=invoice/manage_invoice&id= // Leak place ---> id.
CVE-2022-29986 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via \scbs\classes\Master.php?f=delete_facility.
CVE-2022-29985 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via \scbs\classes\Master.php?f=delete_category.
CVE-2022-29984 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/admin/?page=client/view_client&id=.
CVE-2022-29982 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/admin/maintenance/manage_service.php?id=.
CVE-2022-29981 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/classes/Users.php?f=delete.
CVE-2022-29979 1 Simple Client Management System Project 1 Simple Client Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/classes/Master.php?f=delete_designation.
CVE-2022-29992 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via /scbs/admin/categories/manage_category.php?id=.
CVE-2022-29987 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via /scbs/admin/?page=user/manage_user&id=.
CVE-2022-29993 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via /scbs/admin/bookings/view_booking.php?id=.
CVE-2022-29306 1 Ionizecms 1 Ionize 2022-05-19 7.5 HIGH 9.8 CRITICAL
IonizeCMS v1.0.8.1 was discovered to contain a SQL injection vulnerability via the id_page parameter in application/models/article_model.php.
CVE-2022-29995 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via /scbs/admin/?page=clients/manage_client&id=.
CVE-2022-29988 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via \scbs\classes\Master.php?f=delete.
CVE-2022-29746 1 Money Transfer Management System Project 1 Money Transfer Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Money Transfer Management System 1.0 is vulnerable to SQL Injection via /mtms/classes/Users.php?f=delete.
CVE-2022-29739 1 Money Transfer Management System Project 1 Money Transfer Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Money Transfer Management System 1.0 is vulnerable to SQL Injection via /mtms/admin/?page=user/manage_user&id=.
CVE-2022-29738 1 Money Transfer Management System Project 1 Money Transfer Management System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Money Transfer Management System 1.0 is vulnerable to SQL Injection via /mtms/admin/?page=transaction/send&id=, id.
CVE-2022-29994 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via /scbs/admin/?page=facilities/manage_facility&id=.
CVE-2022-29990 1 Online Sports Complex Booking System Project 1 Online Sports Complex Booking System 2022-05-19 7.5 HIGH 9.8 CRITICAL
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via /scbs/admin/categories/view_category.php?id=.