| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2019-12327 | 1 Akuvox | 2 Sp-r50p, Sp-r50p Firmware | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| Hardcoded credentials in the Akuvox R50P VoIP phone 50.0.6.156 allow an attacker to get access to the device via telnet. The telnet service is running on port 2323; it cannot be turned off and the credentials cannot be changed. | |||||
| CVE-2019-11926 | 1 Facebook | 1 Hhvm | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Insufficient boundary checks when processing M_SOFx markers from JPEG headers in the GD extension could allow access to out-of-bounds memory via a maliciously constructed invalid JPEG input. This issue affects HHVM versions prior to 3.30.9, all versions between 4.0.0 and 4.8.3, all versions between 4.9.0 and 4.15.2, and versions 4.16.0 to 4.16.3, 4.17.0 to 4.17.2, 4.18.0 to 4.18.1, 4.19.0, 4.20.0 to 4.20.1. | |||||
| CVE-2019-10959 | 1 Bd | 10 Alaris Cc Syringe Pump, Alaris Cc Syringe Pump Firmware, Alaris Gateway Workstation and 7 more | 2019-10-09 | 7.5 HIGH | 10.0 CRITICAL |
| BD Alaris Gateway Workstation Versions, 1.1.3 Build 10, 1.1.3 MR Build 11, 1.2 Build 15, 1.3.0 Build 14, 1.3.1 Build 13, This does not impact the latest firmware Versions 1.3.2 and 1.6.1, Additionally, the following products using software Version 2.3.6 and below, Alaris GS, Alaris GH, Alaris CC, Alaris TIVA, The application does not restrict the upload of malicious files during a firmware update. | |||||
| CVE-2019-10431 | 1 Jenkins | 1 Script Security | 2019-10-09 | 6.5 MEDIUM | 9.9 CRITICAL |
| A sandbox bypass vulnerability in Jenkins Script Security Plugin 1.64 and earlier related to the handling of default parameter expressions in constructors allowed attackers to execute arbitrary code in sandboxed scripts. | |||||
| CVE-2019-1010062 | 1 Pluck-cms | 1 Pluckcms | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| PluckCMS 4.7.4 and earlier is affected by: CWE-434 Unrestricted Upload of File with Dangerous Type. The impact is: get webshell. The component is: data/inc/images.php line36. The attack vector is: modify the MIME TYPE on HTTP request to upload a php file. The fixed version is: after commit 09f0ab871bf633973cfd9fc4fe59d4a912397cf8. | |||||
| CVE-2019-10137 | 1 Redhat | 2 Satellite, Spacewalk | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A path traversal flaw was found in spacewalk-proxy, all versions through 2.9, in the way the proxy processes cached client tokens. A remote, unauthenticated attacker could use this flaw to test the existence of arbitrary files, if they have access to the proxy's filesystem, or can execute arbitrary code in the context of the httpd process. | |||||
| CVE-2019-1010275 | 1 Helm | 1 Helm | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| helm Before 2.7.2 is affected by: CWE-295: Improper Certificate Validation. The impact is: Unauthorized clients could connect to the server because self-signed client certs were aloowed. The component is: helm (many files updated, see https://github.com/helm/helm/pull/3152/files/1096813bf9a425e2aa4ac755b6c991b626dfab50). The attack vector is: A malicious client could connect to the server over the network. The fixed version is: 2.7.2. | |||||
| CVE-2019-1010200 | 1 Google | 1 Voice Builder | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| Voice Builder Prior to commit c145d4604df67e6fc625992412eef0bf9a85e26b and f6660e6d8f0d1d931359d591dbdec580fef36d36 is affected by: CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'). The impact is: Remote code execution with the same privileges as the servers. The component is: Two web servers in the projects expose three vulnerable endpoints that can be accessed remotely. The endpoints are defined at: - /tts: https://github.com/google/voice-builder/blob/3a449a3e8d5100ff323161c89b897f6d5ccdb6f9/merlin_model_server/api.js#L34 - /alignment: https://github.com/google/voice-builder/blob/3a449a3e8d5100ff323161c89b897f6d5ccdb6f9/festival_model_server/api.js#L28 - /tts: https://github.com/google/voice-builder/blob/3a449a3e8d5100ff323161c89b897f6d5ccdb6f9/festival_model_server/api.js#L65. The attack vector is: Attacker sends a GET request to the vulnerable endpoint with a specially formatted query parameter. The fixed version is: After commit f6660e6d8f0d1d931359d591dbdec580fef36d36. | |||||
| CVE-2019-1003015 | 1 Jenkins | 1 Job Import | 2019-10-09 | 6.4 MEDIUM | 9.1 CRITICAL |
| An XML external entity processing vulnerability exists in Jenkins Job Import Plugin 2.1 and earlier in src/main/java/org/jenkins/ci/plugins/jobimport/client/RestApiClient.java that allows attackers with the ability to control the HTTP server (Jenkins) queried in preparation of job import to read arbitrary files, perform a denial of service attack, etc. | |||||
| CVE-2019-0022 | 1 Juniper | 3 Advanced Threat Prevention, Atp400, Atp700 | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3. | |||||
| CVE-2018-8914 | 1 Synology | 1 Media Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| SQL injection vulnerability in UPnP DMA in Synology Media Server before 1.7.6-2842 and before 1.4-2654 allows remote attackers to execute arbitrary SQL commands via the ObjectID parameter. | |||||
| CVE-2018-8919 | 1 Synology | 1 Diskstation Manager | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| Information exposure vulnerability in SYNO.Core.Desktop.SessionData in Synology DiskStation Manager (DSM) before 6.1.6-15266 allows remote attackers to steal credentials via unspecified vectors. | |||||
| CVE-2018-9866 | 1 Sonicwall | 1 Global Management System | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability in lack of validation of user-supplied parameters pass to XML-RPC calls on SonicWall Global Management System (GMS) virtual appliance's, allow remote user to execute arbitrary code. This vulnerability affected GMS version 8.1 and earlier. | |||||
| CVE-2019-0020 | 1 Juniper | 3 Advanced Threat Prevention, Atp400, Atp700 | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3. | |||||
| CVE-2018-6703 | 1 Mcafee | 1 Agent | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Use After Free in Remote logging (which is disabled by default) in McAfee McAfee Agent (MA) 5.x prior to 5.6.0 allows remote unauthenticated attackers to cause a Denial of Service and potentially a remote code execution via a specially crafted HTTP header sent to the logging service. | |||||
| CVE-2018-7528 | 1 Geutebrueck | 4 G-cam\/efd-2250, G-cam\/efd-2250 Firmware, Topfd-2125 and 1 more | 2019-10-09 | 6.4 MEDIUM | 9.1 CRITICAL |
| An SQL injection vulnerability has been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which may allow an attacker to alter stored data. | |||||
| CVE-2018-8840 | 2 Indusoft, Industrial-software | 2 Web Studio, Intouch Machine Edition 2017 | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution. | |||||
| CVE-2018-7364 | 1 Zte | 1 Zxin10 | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| All versions up to ZXINOS-RESV1.01.43 of the ZTE ZXIN10 product European region are impacted by improper access control vulnerability. Due to improper access control to devcomm process, an unauthorized remote attacker can exploit this vulnerability to execute arbitrary code with root privileges. | |||||
| CVE-2018-8869 | 1 Lantech | 2 Ids 2102, Ids 2102 Firmware | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| In Lantech IDS 2102 2.0 and prior, nearly all input fields allow for arbitrary input on the device. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | |||||
| CVE-2018-7500 | 1 Osisoft | 2 Pi Vision, Pi Web Api | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A Permissions, Privileges, and Access Controls issue was discovered in OSIsoft PI Web API versions 2017 R2 and prior. Privileges may be escalated, giving attackers access to the PI System via the service account. | |||||
| CVE-2018-7532 | 1 Geutebrueck | 4 G-cam\/efd-2250, G-cam\/efd-2250 Firmware, Topfd-2125 and 1 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Unauthentication vulnerabilities have been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which may allow remote code execution. | |||||
| CVE-2018-7497 | 1 Advantech | 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several untrusted pointer dereference vulnerabilities have been identified, which may allow an attacker to execute arbitrary code. | |||||
| CVE-2018-7498 | 1 Philips | 2 Alice 6, Alice 6 Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| In Philips Alice 6 System version R8.0.2 or prior, the lack of proper data encryption passes up the guarantees of confidentiality, integrity, and accountability that properly implemented encryption conveys. | |||||
| CVE-2018-7518 | 1 Beaconmedaes | 2 Scroll Medical Air Systems, Scroll Medical Air Systems Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner. | |||||
| CVE-2018-7505 | 1 Advantech | 4 Webaccess, Webaccess\/nms, Webaccess Dashboard and 1 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a TFTP application has unrestricted file uploads to the web application without authorization, which may allow an attacker to execute arbitrary code. | |||||
| CVE-2018-7510 | 1 Beaconmedaes | 2 Scroll Medical Air Systems, Scroll Medical Air Systems Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication. | |||||
| CVE-2018-7820 | 1 Schneider-electric | 8 Ap9630, Ap9630 Firmware, Ap9631 and 5 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled. | |||||
| CVE-2018-8850 | 1 Philips | 1 E-alert Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution. | |||||
| CVE-2018-8851 | 1 Echelon | 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface. | |||||
| CVE-2018-8855 | 1 Echelon | 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP. | |||||
| CVE-2018-8858 | 1 Vecna | 2 Vgo, Vgo Firmware | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| If an attacker has access to the firmware from the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be able to extract credentials. | |||||
| CVE-2018-8859 | 1 Echelon | 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can bypass the required authentication specified in the security configuration file by including extra characters in the directory name when specifying the directory to be accessed. This vulnerability does not affect the i.LON 600 product. | |||||
| CVE-2018-5468 | 1 Philips | 1 Intellispace Portal | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code | |||||
| CVE-2018-5469 | 1 Belden | 134 Hirschmann M1-8mm-sc, Hirschmann M1-8sfp, Hirschmann M1-8sm-sc and 131 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An improper restriction of excessive authentication vulnerability in the web interface has been identified, which may allow an attacker to brute force authentication. | |||||
| CVE-2018-5472 | 1 Philips | 1 Intellispace Portal | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code. | |||||
| CVE-2018-5474 | 1 Philips | 1 Intellispace Portal | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash. | |||||
| CVE-2018-6333 | 1 Facebook | 1 Nuclide | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| The hhvm-attach deep link handler in Nuclide did not properly sanitize the provided hostname parameter when rendering. As a result, a malicious URL could be used to render HTML and other content inside of the editor's context, which could potentially be chained to lead to code execution. This issue affected Nuclide prior to v0.290.0. | |||||
| CVE-2018-4853 | 1 Siemens | 4 Siclock Tc100, Siclock Tc100 Firmware, Siclock Tc400 and 1 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device. | |||||
| CVE-2018-6667 | 1 Mcafee | 1 Mcafee Web Gateway | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Authentication Bypass vulnerability in the administrative user interface in McAfee Web Gateway 7.8.1.0 through 7.8.1.5 allows remote attackers to execute arbitrary code via Java management extensions (JMX). | |||||
| CVE-2018-6339 | 1 Whatsapp | 1 Whatsapp | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| When receiving calls using WhatsApp on Android, a stack allocation failed to properly account for the amount of data being passed in. An off-by-one error meant that data was written beyond the allocated space on the stack. This issue affects WhatsApp for Android starting in version 2.18.180 and was fixed in version 2.18.295. It also affects WhatsApp Business for Android starting in version v2.18.103 and was fixed in version v2.18.150. | |||||
| CVE-2018-6498 | 1 Microfocus | 5 Data Center Automation, Hybrid Cloud Management, Network Operations Management and 2 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Remote Code Execution in the following products Hybrid Cloud Management Containerized Suite HCM2017.11, HCM2018.02, HCM2018.05, Operations Bridge Containerized Suite 2017.11, 2018.02, 2018.05, Data Center Automation Containerized Suite 2017.01 until 2018.05, Service Management Automation Suite 2017.11, 2018.02, 2018.05 and Network Operations Management (NOM) Suite CDF 2017.11, 2018.02, 2018.05 will allow Remote Code Execution. | |||||
| CVE-2018-6331 | 1 Facebook | 1 Buck | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Buck parser-cache command loads/saves state using Java serialized object. If the state information is maliciously crafted, deserializing it could lead to code execution. This issue affects Buck versions prior to v2018.06.25.01. | |||||
| CVE-2018-6486 | 1 Microfocus | 2 Fortify Audit Workbench, Fortify Software Security Center | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| XML External Entity (XXE) vulnerability in Micro Focus Fortify Audit Workbench (AWB) and Micro Focus Fortify Software Security Center (SSC), versions 16.10, 16.20, 17.10. This vulnerability could be exploited to allow a XML External Entity (XXE) injection. | |||||
| CVE-2018-6334 | 1 Facebook | 1 Hhvm | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Multipart-file uploads call variables to be improperly registered in the global scope. In cases where variables are not declared explicitly before being used this can lead to unexpected behavior. This affects all supported versions of HHVM prior to the patch (3.25.1, 3.24.5, and 3.21.9 and below). | |||||
| CVE-2018-5455 | 1 Moxa | 8 Oncell G3110-hspa, Oncell G3110-hspa-t, Oncell G3110-hspa-t Firmware and 5 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions. | |||||
| CVE-2018-5459 | 1 Wago | 19 750-8202, 750-8202\/025-000, 750-8202\/025-001 and 16 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. | |||||
| CVE-2018-5439 | 1 Nortekcontrol | 2 Emerge E3, Emerge E3 Firmware | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges. | |||||
| CVE-2018-5435 | 1 Tibco | 5 Spotfire Analyst, Spotfire Analytics Platform For Aws, Spotfire Deployment Kit and 2 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| The TIBCO Spotfire Client and TIBCO Spotfire Web Player Client components of TIBCO Software Inc.'s TIBCO Spotfire Analyst, TIBCO Spotfire Analytics Platform for AWS Marketplace, TIBCO Spotfire Deployment Kit, TIBCO Spotfire Desktop, and TIBCO Spotfire Desktop Language Packs contain multiple vulnerabilities that may allow for remote code execution. Affected releases are TIBCO Software Inc.'s TIBCO Spotfire Analyst: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0; 7.12.0, TIBCO Spotfire Analytics Platform for AWS Marketplace: versions up to and including 7.12.0, TIBCO Spotfire Deployment Kit: versions up to and including 7.8.0; 7.9.0;7.9.1;7.10.0;7.10.1;7.11.0; 7.12.0, TIBCO Spotfire Desktop: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0;7.12.0, TIBCO Spotfire Desktop Language Packs: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0. | |||||
| CVE-2018-5400 | 2 Arm, Auto-maskin | 5 Arm7, Dcu 210e, Dcu 210e Firmware and 2 more | 2019-10-09 | 6.4 MEDIUM | 9.1 CRITICAL |
| The Auto-Maskin products utilize an undocumented custom protocol to set up Modbus communications with other devices without validating those devices. The originating device sends a message in plaintext, 48:65:6c:6c:6f:20:57:6f:72:6c:64, "Hello World" over UDP ports 44444-44446 to the broadcast address for the LAN. Without verification devices respond to any of these broadcast messages on the LAN with a plaintext reply over UDP containing the device model and firmware version. Following this exchange the devices allow Modbus transmissions between the two devices on the standard Modbus port 502 TCP. Impact: An attacker can exploit this vulnerability to send arbitrary messages to any DCU or RP device through spoofing or replay attacks as long as they have access to the network. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7. | |||||
| CVE-2018-5399 | 1 Auto-maskin | 4 Dcu-210e, Dcu-210e Firmware, Rp-210e and 1 more | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7. | |||||