Vulnerabilities (CVE)

Filtered by CWE-312
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-2809 1 Sage 1 Sage 200 Spain 2023-12-19 N/A 9.8 CRITICAL
Plaintext credential usage vulnerability in Sage 200 Spain 2023.38.001 version, the exploitation of which could allow a remote attacker to extract SQL database credentials from the DLL application. This vulnerability could be linked to known techniques to obtain remote execution of MS SQL commands and escalate privileges on Windows systems because the credentials are stored in plaintext.
CVE-2023-33373 1 Connectedio 1 Connected Io 2023-08-08 N/A 9.8 CRITICAL
Connected IO v2.1.0 and prior keeps passwords and credentials in clear-text format, allowing attackers to exfiltrate the credentials and use them to impersonate the devices.
CVE-2022-25158 1 Mitsubishielectric 32 Fx5uc, Fx5uc-32mr\/ds-ts, Fx5uc-32mr\/ds-ts Firmware and 29 more 2022-06-02 6.4 MEDIUM 9.1 CRITICAL
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GF11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GP21(S)-SX all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote attacker to disclose or tamper with a file in which password hash is saved in cleartext.
CVE-2019-18823 2 Fedoraproject, Wisc 2 Fedora, Htcondor 2022-05-23 7.5 HIGH 9.8 CRITICAL
HTCondor up to and including stable series 8.8.6 and development series 8.9.4 has Incorrect Access Control. It is possible to use a different authentication method to submit a job than the administrator has specified. If the administrator has configured the READ or WRITE methods to include CLAIMTOBE, then it is possible to impersonate another user to the condor_schedd. (For example to submit or remove jobs)
CVE-2022-26148 2 Grafana, Redhat 3 Grafana, Ceph Storage, Storage 2022-05-13 7.5 HIGH 9.8 CRITICAL
An issue was discovered in Grafana through 7.3.4, when integrated with Zabbix. The Zabbix password can be found in the api_jsonrpc.php HTML source code. When the user logs in and allows the user to register, one can right click to view the source code and use Ctrl-F to search for password in api_jsonrpc.php to discover the Zabbix account password and URL address.
CVE-2020-12032 1 Baxter 4 Em1200, Em1200 Firmware, Em2400 and 1 more 2021-11-04 6.4 MEDIUM 9.1 CRITICAL
Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI.
CVE-2021-29954 1 Mozilla 1 Hubs Cloud Reticulum 2021-06-30 5.0 MEDIUM 9.8 CRITICAL
Proxy functionality built into Hubs Cloud’s Reticulum software allowed access to internal URLs, including the metadata service. This vulnerability affects Hubs Cloud < mozillareality/reticulum/1.0.1/20210428201255.
CVE-2019-9873 1 Jetbrains 1 Intellij Idea 2020-08-24 5.0 MEDIUM 9.8 CRITICAL
In several versions of JetBrains IntelliJ IDEA Ultimate, creating Task Servers configurations leads to saving a cleartext unencrypted record of the server credentials in the IDE configuration files. The issue has been fixed in the following versions: 2019.1, 2018.3.5, 2018.2.8, and 2018.1.8.
CVE-2019-0285 1 Sap 1 Crystal Reports 2020-08-24 5.0 MEDIUM 9.8 CRITICAL
The .NET SDK WebForm Viewer in SAP Crystal Reports for Visual Studio (fixed in version 2010) discloses sensitive database information including credentials which can be misused by the attacker.
CVE-2019-11384 1 Zalora 1 Zalora 2020-08-24 5.0 MEDIUM 9.8 CRITICAL
The Zalora application 6.15.1 for Android stores confidential information insecurely on the system (i.e. plain text), which allows a non-root user to find out the username/password of a valid user via /data/data/com.zalora.android/shared_prefs/login_data.xml.
CVE-2019-13096 1 Tronlink 1 Wallet 2020-08-24 5.0 MEDIUM 9.8 CRITICAL
TronLink Wallet 2.2.0 stores user wallet keystore in plaintext and places them in insecure storage. An attacker can read and reuse the user keystore of a valid user via /data/data/com.tronlink.wallet/shared_prefs/<wallet-name>.xml to gain unauthorized access.
CVE-2019-9823 1 Jetbrains 1 Intellij Idea 2020-08-24 5.0 MEDIUM 9.8 CRITICAL
In several JetBrains IntelliJ IDEA versions, creating remote run configurations of JavaEE application servers leads to saving a cleartext record of the server credentials in the IDE configuration files. The issue has been fixed in the following versions: 2018.3.5, 2018.2.8, 2018.1.8.
CVE-2020-5723 1 Grandstream 6 Ucm6202, Ucm6202 Firmware, Ucm6204 and 3 more 2020-04-01 5.0 MEDIUM 9.8 CRITICAL
The UCM6200 series 1.0.20.22 and below stores unencrypted user passwords in an SQLite database. This could allow an attacker to retrieve all passwords and possibly gain elevated privileges.
CVE-2019-19228 1 Fronius 132 Datamanager Box 2.0, Datamanager Box 2.0 Firmware, Eco 25.0-3-s and 129 more 2019-12-16 5.0 MEDIUM 9.8 CRITICAL
Fronius Solar Inverter devices before 3.14.1 (HM 1.12.1) allow attackers to bypass authentication because the password for the today account is stored in the /tmp/web_users.conf file.
CVE-2017-5249 1 Wink 1 Wink 2019-10-09 5.0 MEDIUM 9.8 CRITICAL
In version 6.1.0.19 and prior of Wink Labs's Wink - Smart Home Android app, the OAuth token used by the app to authorize user access is not stored in an encrypted and secure manner.
CVE-2017-5250 1 Insteon 1 Insteon For Hub 2019-10-09 5.0 MEDIUM 9.8 CRITICAL
In version 1.9.7 and prior of Insteon's Insteon for Hub Android app, the OAuth token used by the app to authorize user access is not stored in an encrypted and secure manner.
CVE-2018-18641 1 Gitlab 1 Gitlab 2019-10-03 5.0 MEDIUM 9.8 CRITICAL
An issue was discovered in GitLab Community and Enterprise Edition before 11.2.7, 11.3.x before 11.3.8, and 11.4.x before 11.4.3. It has Cleartext Storage of Sensitive Information.
CVE-2018-18394 1 Moxa 1 Thingspro 2019-10-03 5.0 MEDIUM 9.8 CRITICAL
Sensitive Information Stored in Clear Text in Moxa ThingsPro IIoT Gateway and Device Management Software Solutions version 2.1.