Filtered by vendor Rockwellautomation
Subscribe
Filtered by product Factorytalk Services Platform
Subscribe
Search
Total
8 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-22681 | 1 Rockwellautomation | 20 Compact Guardlogix 5370, Compact Guardlogix 5380, Compactlogix 1768 and 17 more | 2022-04-25 | 7.5 HIGH | 9.8 CRITICAL |
| Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. | |||||
| CVE-2020-14516 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2021-03-26 | 7.5 HIGH | 10.0 CRITICAL |
| In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly. | |||||
| CVE-2020-12033 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2020-07-06 | 5.8 MEDIUM | 8.8 HIGH |
| In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges. | |||||
| CVE-2020-6967 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2020-03-27 | 10.0 HIGH | 9.8 CRITICAL |
| In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data. | |||||
| CVE-2018-18981 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services. | |||||
| CVE-2014-9209 | 1 Rockwellautomation | 2 Factorytalk Services Platform, Factorytalk View Studio | 2015-03-31 | 6.9 MEDIUM | N/A |
| Untrusted search path vulnerability in the Clean Utility application in Rockwell Automation FactoryTalk Services Platform before 2.71.00 and FactoryTalk View Studio 8.00.00 and earlier allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. | |||||
| CVE-2012-4714 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2013-04-18 | 7.8 HIGH | N/A |
| Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value. | |||||
| CVE-2012-4713 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2013-04-18 | 7.8 HIGH | N/A |
| Integer signedness error in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a negative integer value. | |||||