Search
Total
201818 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-7524 | 1 Schneider-electric | 2 Modicon M218, Modicon M218 Firmware | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal. | |||||
| CVE-2020-7502 | 1 Schneider-electric | 2 Modicon M218, Modicon M218 Firmware | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (Firmware version 4.3 and prior), which may cause a Denial of Service when specific TCP/IP crafted packets are sent to the Modicon M218 Logic Controller. | |||||
| CVE-2021-46085 | 1 Oneblog Project | 1 Oneblog | 2022-01-31 | 4.0 MEDIUM | 6.5 MEDIUM |
| OneBlog <= 2.2.8 is vulnerable to Insecure Permissions. Low level administrators can delete high-level administrators beyond their authority. | |||||
| CVE-2020-7573 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 6.4 MEDIUM | 6.5 MEDIUM |
| A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control. | |||||
| CVE-2020-7572 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser. | |||||
| CVE-2020-7571 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 3.5 LOW | 5.4 MEDIUM |
| A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users. | |||||
| CVE-2020-7570 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 3.5 LOW | 5.4 MEDIUM |
| A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Stored) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary web script or HTML due to incorrect sanitization of user-supplied data and achieve a Cross-Site Scripting stored attack against other WebReport users. | |||||
| CVE-2020-7569 | 1 Schneider-electric | 1 Webreports | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution. | |||||
| CVE-2021-22777 | 1 Schneider-electric | 1 Sosafe Configurable | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file. | |||||
| CVE-2020-7501 | 1 Schneider-electric | 1 Vijeo Designer | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer. | |||||
| CVE-2020-7498 | 1 Schneider-electric | 2 Os Loader, Unity Loader | 2022-01-31 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results. | |||||
| CVE-2020-7490 | 1 Schneider-electric | 1 Vijeo Designer | 2022-01-31 | 6.9 MEDIUM | 7.8 HIGH |
| A CWE-426: Untrusted Search Path vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 15 and prior) and Vijeo Designer (V6.9 SP9 and prior), which could cause arbitrary code execution on the system running Vijeo Basic when a malicious DLL library is loaded by the Product. | |||||
| CVE-2018-7783 | 1 Schneider-electric | 1 Somachine Basic | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is triggered when input passed to the xml parser is not sanitized while parsing the xml project/template file. | |||||
| CVE-2017-7965 | 1 Schneider-electric | 1 Somachine Hvac | 2022-01-31 | 4.6 MEDIUM | 7.3 HIGH |
| A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller. | |||||
| CVE-2016-2292 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 4.3 MEDIUM | 6.5 MEDIUM |
| Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. | |||||
| CVE-2016-2291 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 4.3 MEDIUM | 6.5 MEDIUM |
| Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors. | |||||
| CVE-2016-2290 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 6.8 MEDIUM | 8.8 HIGH |
| Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. | |||||
| CVE-2015-7921 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2022-01-31 | 6.4 MEDIUM | 9.1 CRITICAL |
| The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded credentials, which makes it easier for remote attackers to bypass authentication by leveraging knowledge of these credentials. | |||||
| CVE-2021-43863 | 1 Nextcloud | 1 Nextcloud | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| The Nextcloud Android app is the Android client for Nextcloud, a self-hosted productivity platform. The Nextcloud Android app uses content providers to manage its data. Prior to version 3.18.1, the providers `FileContentProvider` and `DiskLruImageCacheFileProvider` have security issues (an SQL injection, and an insufficient permission control, respectively) that allow malicious apps in the same device to access Nextcloud's data bypassing the permission control system. Users should upgrade to version 3.18.1 to receive a patch. There are no known workarounds aside from upgrading. | |||||
| CVE-2021-34870 | 1 Netgear | 1 Xr1000 | 2022-01-31 | 3.3 LOW | 6.5 MEDIUM |
| This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of NETGEAR XR1000 1.0.0.52_1.0.38 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of SOAP messages. The issue results from a lack of authentication required for a privileged request. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-13325. | |||||
| CVE-2021-22784 | 1 Schneider-electric | 1 C-bus Toolkit | 2022-01-31 | 3.5 LOW | 5.7 MEDIUM |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system. | |||||
| CVE-2021-22705 | 1 Schneider-electric | 9 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 6 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert | |||||
| CVE-2021-22698 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |||||
| CVE-2021-22697 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2022-01-31 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed. | |||||
| CVE-2020-7560 | 1 Schneider-electric | 2 Ecostruxure Control Expert, Unity Pro | 2022-01-31 | 6.8 MEDIUM | 8.6 HIGH |
| A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. | |||||
| CVE-2020-7544 | 1 Schneider-electric | 1 Operator Terminal Expert Runtime | 2022-01-31 | 7.2 HIGH | 7.8 HIGH |
| A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert. | |||||
| CVE-2020-7538 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 5.0 MEDIUM | 7.5 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. | |||||
| CVE-2020-28213 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 6.5 MEDIUM | 8.8 HIGH |
| A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus. | |||||
| CVE-2020-28212 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 7.5 HIGH | 9.8 CRITICAL |
| A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus. | |||||
| CVE-2020-28211 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger. | |||||
| CVE-2020-28209 | 2 Microsoft, Schneider-electric | 2 Windows, Enterprise Server Installer | 2022-01-31 | 4.4 MEDIUM | 7.0 HIGH |
| A CWE-428 Windows Unquoted Search Path vulnerability exists in EcoStruxure Building Operation Enterprise Server installer V1.9 - V3.1 and Enterprise Central installer V2.0 - V3.1 that could cause any local Windows user who has write permission on at least one of the subfolders of the Connect Agent service binary path, being able to gain the privilege of the user who started the service. By default, the Enterprise Server and Enterprise Central is always installed at a location requiring Administrator privileges so the vulnerability is only valid if the application has been installed on a non-secure location. | |||||
| CVE-2020-28210 | 1 Schneider-electric | 1 Ecostruxure Building Operation | 2022-01-31 | 4.3 MEDIUM | 6.1 MEDIUM |
| A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser. | |||||
| CVE-2020-10626 | 2 Fazecast, Schneider-electric | 2 Jserialcomm, Ecostruxure It Gateway | 2022-01-31 | 6.9 MEDIUM | 7.8 HIGH |
| In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code. | |||||
| CVE-2019-6855 | 1 Schneider-electric | 44 Ecostruxure Control Expert, Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware and 41 more | 2022-01-31 | 7.5 HIGH | 7.3 HIGH |
| Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. | |||||
| CVE-2016-2383 | 3 Canonical, Linux, Opensuse | 3 Ubuntu Linux, Linux Kernel, Leap | 2022-01-31 | 2.1 LOW | 5.5 MEDIUM |
| The adjust_branches function in kernel/bpf/verifier.c in the Linux kernel before 4.5 does not consider the delta in the backward-jump case, which allows local users to obtain sensitive information from kernel memory by creating a packet filter and then loading crafted BPF instructions. | |||||
| CVE-2019-3843 | 4 Canonical, Fedoraproject, Netapp and 1 more | 8 Ubuntu Linux, Fedora, Cn1610 and 5 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| It was discovered that a systemd service that uses DynamicUser property can create a SUID/SGID binary that would be allowed to run as the transient service UID/GID even after the service is terminated. A local attacker may use this flaw to access resources that will be owned by a potentially different service in the future, when the UID/GID will be recycled. | |||||
| CVE-2019-3844 | 3 Canonical, Netapp, Systemd Project | 7 Ubuntu Linux, Cn1610, Cn1610 Firmware and 4 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| It was discovered that a systemd service that uses DynamicUser property can get new privileges through the execution of SUID binaries, which would allow to create binaries owned by the service transient group with the setgid bit set. A local attacker may use this flaw to access resources that will be owned by a potentially different service in the future, when the GID will be recycled. | |||||
| CVE-2019-3842 | 4 Debian, Fedoraproject, Redhat and 1 more | 4 Debian Linux, Fedora, Enterprise Linux and 1 more | 2022-01-31 | 4.4 MEDIUM | 7.0 HIGH |
| In systemd before v242-rc4, it was discovered that pam_systemd does not properly sanitize the environment before using the XDG_SEAT variable. It is possible for an attacker, in some particular configurations, to set a XDG_SEAT environment variable which allows for commands to be checked against polkit policies using the "allow_active" element rather than "allow_any". | |||||
| CVE-2020-13776 | 3 Fedoraproject, Netapp, Systemd Project | 4 Fedora, Active Iq Unified Manager, Solidfire \& Hci Management Node and 1 more | 2022-01-31 | 6.2 MEDIUM | 6.7 MEDIUM |
| systemd through v245 mishandles numerical usernames such as ones composed of decimal digits or 0x followed by hex digits, as demonstrated by use of root privileges when privileges of the 0x0 user account were intended. NOTE: this issue exists because of an incomplete fix for CVE-2017-1000082. | |||||
| CVE-2018-16888 | 4 Canonical, Netapp, Redhat and 1 more | 5 Ubuntu Linux, Active Iq Performance Analytics Services, Element Software and 2 more | 2022-01-31 | 1.9 LOW | 4.7 MEDIUM |
| It was discovered systemd does not correctly check the content of PIDFile files before using it to kill processes. When a service is run from an unprivileged user (e.g. User field set in the service file), a local attacker who is able to write to the PIDFile of the mentioned service may use this flaw to trick systemd into killing other services and/or privileged processes. Versions before v237 are vulnerable. | |||||
| CVE-2018-16865 | 5 Canonical, Debian, Oracle and 2 more | 11 Ubuntu Linux, Debian Linux, Communications Session Border Controller and 8 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| An allocation of memory without limits, that could result in the stack clashing with another memory region, was discovered in systemd-journald when many entries are sent to the journal socket. A local attacker, or a remote one if systemd-journal-remote is used, may use this flaw to crash systemd-journald or execute code with journald privileges. Versions through v240 are vulnerable. | |||||
| CVE-2018-16864 | 5 Canonical, Debian, Oracle and 2 more | 11 Ubuntu Linux, Debian Linux, Communications Session Border Controller and 8 more | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| An allocation of memory without limits, that could result in the stack clashing with another memory region, was discovered in systemd-journald when a program with long command line arguments calls syslog. A local attacker may use this flaw to crash systemd-journald or escalate his privileges. Versions through v240 are vulnerable. | |||||
| CVE-2018-15688 | 4 Canonical, Debian, Redhat and 1 more | 9 Ubuntu Linux, Debian Linux, Enterprise Linux Desktop and 6 more | 2022-01-31 | 5.8 MEDIUM | 8.8 HIGH |
| A buffer overflow vulnerability in the dhcp6 client of systemd allows a malicious dhcp6 server to overwrite heap memory in systemd-networkd. Affected releases are systemd: versions up to and including 239. | |||||
| CVE-2018-15687 | 2 Canonical, Systemd Project | 2 Ubuntu Linux, Systemd | 2022-01-31 | 6.9 MEDIUM | 7.0 HIGH |
| A race condition in chown_one() of systemd allows an attacker to cause systemd to set arbitrary permissions on arbitrary files. Affected releases are systemd versions up to and including 239. | |||||
| CVE-2018-15686 | 4 Canonical, Debian, Oracle and 1 more | 4 Ubuntu Linux, Debian Linux, Communications Cloud Native Core Network Function Cloud Native Environment and 1 more | 2022-01-31 | 7.2 HIGH | 7.8 HIGH |
| A vulnerability in unit_deserialize of systemd allows an attacker to supply arbitrary state across systemd re-execution via NotifyAccess. This can be used to improperly influence systemd execution and possibly lead to root privilege escalation. Affected releases are systemd versions up to and including 239. | |||||
| CVE-2018-1049 | 4 Canonical, Debian, Redhat and 1 more | 11 Ubuntu Linux, Debian Linux, Enterprise Linux and 8 more | 2022-01-31 | 4.3 MEDIUM | 5.9 MEDIUM |
| In systemd prior to 234 a race condition exists between .mount and .automount units such that automount requests from kernel may not be serviced by systemd resulting in kernel holding the mountpoint and any processes that try to use said mount will hang. A race condition like this may lead to denial of service, until mount points are unmounted. | |||||
| CVE-2018-6954 | 3 Canonical, Opensuse, Systemd Project | 3 Ubuntu Linux, Leap, Systemd | 2022-01-31 | 7.2 HIGH | 7.8 HIGH |
| systemd-tmpfiles in systemd through 237 mishandles symlinks present in non-terminal path components, which allows local users to obtain ownership of arbitrary files via vectors involving creation of a directory and a file under that directory, and later replacing that directory with a symlink. This occurs even if the fs.protected_symlinks sysctl is turned on. | |||||
| CVE-2017-18078 | 3 Debian, Opensuse, Systemd Project | 3 Debian Linux, Leap, Systemd | 2022-01-31 | 4.6 MEDIUM | 7.8 HIGH |
| systemd-tmpfiles in systemd before 237 attempts to support ownership/permission changes on hardlinked files even if the fs.protected_hardlinks sysctl is turned off, which allows local users to bypass intended access restrictions via vectors involving a hard link to a file for which the user lacks write access, as demonstrated by changing the ownership of the /etc/passwd file. | |||||
| CVE-2017-13715 | 1 Linux | 1 Linux Kernel | 2022-01-31 | 10.0 HIGH | 9.8 CRITICAL |
| The __skb_flow_dissect function in net/core/flow_dissector.c in the Linux kernel before 4.3 does not ensure that n_proto, ip_proto, and thoff are initialized, which allows remote attackers to cause a denial of service (system crash) or possibly execute arbitrary code via a single crafted MPLS packet. | |||||
| CVE-2017-1000082 | 1 Systemd Project | 1 Systemd | 2022-01-31 | 10.0 HIGH | 9.8 CRITICAL |
| systemd v233 and earlier fails to safely parse usernames starting with a numeric digit (e.g. "0day"), running the service in question with root privileges rather than the user intended. | |||||