Filtered by vendor Rockwellautomation
Subscribe
Search
Total
167 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-5807 | 1 Rockwellautomation | 1 Factorytalk Diagnostics | 2020-12-30 | 5.0 MEDIUM | 7.5 HIGH |
| An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected. | |||||
| CVE-2020-5801 | 1 Rockwellautomation | 1 Factorytalk Linx | 2020-12-30 | 5.0 MEDIUM | 7.5 HIGH |
| An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected. | |||||
| CVE-2020-12025 | 1 Rockwellautomation | 1 Studio 5000 Logix Designer | 2020-12-15 | 4.3 MEDIUM | 3.3 LOW |
| Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program. | |||||
| CVE-2020-27255 | 1 Rockwellautomation | 1 Factorytalk Linx | 2020-11-30 | 5.0 MEDIUM | 7.5 HIGH |
| A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR). | |||||
| CVE-2020-27253 | 1 Rockwellautomation | 1 Factorytalk Linx | 2020-11-30 | 7.8 HIGH | 7.5 HIGH |
| A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device. | |||||
| CVE-2020-27251 | 1 Rockwellautomation | 1 Factorytalk Linx | 2020-11-30 | 7.5 HIGH | 9.8 CRITICAL |
| A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution. | |||||
| CVE-2019-6553 | 1 Rockwellautomation | 1 Rslinx | 2020-10-06 | 7.5 HIGH | 9.8 CRITICAL |
| A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition. | |||||
| CVE-2019-10952 | 1 Rockwellautomation | 8 Armor Compact Guardlogix 5370, Armor Compact Guardlogix 5370 Firmware, Compactlogix 5370 L1 and 5 more | 2020-10-02 | 7.5 HIGH | 9.8 CRITICAL |
| An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 to 30.014 and earlier systems. | |||||
| CVE-2019-10970 | 1 Rockwellautomation | 2 Panelview 5510, Panelview 5510 Firmware | 2020-10-01 | 10.0 HIGH | 9.8 CRITICAL |
| In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system. | |||||
| CVE-2018-0172 | 2 Cisco, Rockwellautomation | 8 Ios, Ios Xe, Allen-bradley Armorstratix 5700 and 5 more | 2020-09-04 | 7.8 HIGH | 8.6 HIGH |
| A vulnerability in the DHCP option 82 encapsulation functionality of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service (DoS) condition. The vulnerability exists because the affected software performs incomplete input validation of option 82 information that it receives in DHCP Version 4 (DHCPv4) packets from DHCP relay agents. An attacker could exploit this vulnerability by sending a crafted DHCPv4 packet to an affected device. A successful exploit could allow the attacker to cause a heap overflow condition on the affected device, which will cause the device to reload and result in a DoS condition. Cisco Bug IDs: CSCvg62730. | |||||
| CVE-2018-0155 | 2 Cisco, Rockwellautomation | 13 Catalyst 4500-x Series Switches \(k10\), Catalyst 4500 Supervisor Engine 6-e \(k5\), Catalyst 4500 Supervisor Engine 6l-e \(k10\) and 10 more | 2020-09-04 | 7.8 HIGH | 8.6 HIGH |
| A vulnerability in the Bidirectional Forwarding Detection (BFD) offload implementation of Cisco Catalyst 4500 Series Switches and Cisco Catalyst 4500-X Series Switches could allow an unauthenticated, remote attacker to cause a crash of the iosd process, causing a denial of service (DoS) condition. The vulnerability is due to insufficient error handling when the BFD header in a BFD packet is incomplete. An attacker could exploit this vulnerability by sending a crafted BFD message to or across an affected switch. A successful exploit could allow the attacker to trigger a reload of the system. This vulnerability affects Catalyst 4500 Supervisor Engine 6-E (K5), Catalyst 4500 Supervisor Engine 6L-E (K10), Catalyst 4500 Supervisor Engine 7-E (K10), Catalyst 4500 Supervisor Engine 7L-E (K10), Catalyst 4500E Supervisor Engine 8-E (K10), Catalyst 4500E Supervisor Engine 8L-E (K10), Catalyst 4500E Supervisor Engine 9-E (K10), Catalyst 4500-X Series Switches (K10), Catalyst 4900M Switch (K5), Catalyst 4948E Ethernet Switch (K5). Cisco Bug IDs: CSCvc40729. | |||||
| CVE-2018-19616 | 1 Rockwellautomation | 2 Powermonitor 1000, Powermonitor 1000 Firmware | 2020-08-24 | 6.8 MEDIUM | 8.1 HIGH |
| An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element. | |||||
| CVE-2019-13510 | 1 Rockwellautomation | 1 Arena Simulation Software | 2020-08-04 | 6.8 MEDIUM | 7.8 HIGH |
| Rockwell Automation Arena Simulation Software versions 16.00.00 and earlier contain a USE AFTER FREE CWE-416. A maliciously crafted Arena file opened by an unsuspecting user may result in the application crashing or the execution of arbitrary code. | |||||
| CVE-2020-12033 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2020-07-06 | 5.8 MEDIUM | 8.8 HIGH |
| In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges. | |||||
| CVE-2020-12005 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2020-06-24 | 7.8 HIGH | 7.5 HIGH |
| FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition. | |||||
| CVE-2020-12003 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2020-06-24 | 5.0 MEDIUM | 7.5 HIGH |
| FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive. | |||||
| CVE-2020-11999 | 1 Rockwellautomation | 2 Factorytalk Linx, Rslinx Classic | 2020-06-24 | 5.5 MEDIUM | 8.1 HIGH |
| FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data. | |||||
| CVE-2020-12034 | 1 Rockwellautomation | 5 Eds Subsystem, Rslinx, Rslinx Enterprise and 2 more | 2020-05-22 | 4.8 MEDIUM | 8.2 HIGH |
| Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. | |||||
| CVE-2020-6967 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2020-03-27 | 10.0 HIGH | 9.8 CRITICAL |
| In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data. | |||||
| CVE-2020-6990 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 10.0 HIGH | 9.8 CRITICAL |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller. | |||||
| CVE-2020-6984 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 5.0 MEDIUM | 7.5 HIGH |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable. | |||||
| CVE-2020-6988 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 5.0 MEDIUM | 7.5 HIGH |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials. | |||||
| CVE-2020-6980 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2020-03-20 | 2.1 LOW | 3.3 LOW |
| Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext. | |||||
| CVE-2019-10955 | 1 Rockwellautomation | 11 Compactlogix 5370 L1, Compactlogix 5370 L1 Firmware, Compactlogix 5370 L2 and 8 more | 2020-02-10 | 5.8 MEDIUM | 6.1 MEDIUM |
| In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that could run or download arbitrary malware on the user’s machine. | |||||
| CVE-2013-2807 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2020-02-10 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 | |||||
| CVE-2013-2805 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2020-02-10 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 | |||||
| CVE-2013-2806 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2020-02-10 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 | |||||
| CVE-2010-5305 | 1 Rockwellautomation | 5 Plc5 1785-lx, Plc5 1785-lx Firmware, Rslogix and 2 more | 2020-02-10 | 7.5 HIGH | 9.8 CRITICAL |
| The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services. | |||||
| CVE-2019-13521 | 1 Rockwellautomation | 1 Arena Simulation | 2020-02-03 | 6.8 MEDIUM | 7.8 HIGH |
| A maliciously crafted program file opened by an unsuspecting user of Rockwell Automation Arena Simulation Software version 16.00.00 and earlier may result in the limited exposure of information related to the targeted workstation. Rockwell Automation has released version 16.00.01 of Arena Simulation Software to address the reported vulnerabilities. | |||||
| CVE-2019-13519 | 1 Rockwellautomation | 1 Arena Simulation | 2020-02-03 | 6.8 MEDIUM | 7.8 HIGH |
| A maliciously crafted program file opened by an unsuspecting user of Rockwell Automation Arena Simulation Software version 16.00.00 and earlier may result in the limited exposure of information related to the targeted workstation. Rockwell Automation has released version 16.00.01 of Arena Simulation Software to address the reported vulnerabilities. | |||||
| CVE-2019-13527 | 1 Rockwellautomation | 1 Arena Simulation Software | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| In Rockwell Automation Arena Simulation Software Cat. 9502-Ax, Versions 16.00.00 and earlier, a maliciously crafted Arena file opened by an unsuspecting user may result in the use of a pointer that has not been initialized. | |||||
| CVE-2018-8843 | 1 Rockwellautomation | 1 Arena | 2019-10-09 | 4.3 MEDIUM | 5.5 MEDIUM |
| Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data.. | |||||
| CVE-2018-18981 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services. | |||||
| CVE-2018-19016 | 1 Rockwellautomation | 2 Ethernet\/ip Web Server Module 1756-eweb, Ethernet\/ip Web Server Module 1768-eweb | 2019-10-09 | 7.8 HIGH | 7.5 HIGH |
| Rockwell Automation EtherNet/IP Web Server Modules 1756-EWEB (includes 1756-EWEBK) Version 5.001 and earlier, and CompactLogix 1768-EWEB Version 2.005 and earlier. A remote attacker could send a crafted UDP packet to the SNMP service causing a denial-of-service condition to occur until the affected product is restarted. | |||||
| CVE-2018-14829 | 1 Rockwellautomation | 1 Rslinx | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code. | |||||
| CVE-2018-14821 | 1 Rockwellautomation | 1 Rslinx | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality. | |||||
| CVE-2018-14827 | 1 Rockwellautomation | 1 Rslinx | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality. | |||||
| CVE-2018-10619 | 1 Rockwellautomation | 2 Factorytalk Linx Gateway, Rslinx Classic | 2019-10-09 | 4.6 MEDIUM | 7.8 HIGH |
| An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation. | |||||
| CVE-2018-0174 | 2 Cisco, Rockwellautomation | 11 7600 Series Route Switch Processor 720, 7600 Series Supervisor Engine 32, 7600 Series Supervisor Engine 720 and 8 more | 2019-10-09 | 7.8 HIGH | 8.6 HIGH |
| A vulnerability in the DHCP option 82 encapsulation functionality of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a denial of service (DoS) condition. The vulnerability exists because the affected software performs incomplete input validation of option 82 information that it receives in DHCP Version 4 (DHCPv4) packets from DHCP relay agents. An attacker could exploit this vulnerability by sending a crafted DHCPv4 packet to an affected device. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a DoS condition. Cisco Bug IDs: CSCuh91645. | |||||
| CVE-2018-0158 | 2 Cisco, Rockwellautomation | 12 Asr 1001-hx, Asr 1001-x, Asr 1002-hx and 9 more | 2019-10-09 | 7.8 HIGH | 8.6 HIGH |
| A vulnerability in the Internet Key Exchange Version 2 (IKEv2) module of Cisco IOS Software and Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause a memory leak or a reload of an affected device that leads to a denial of service (DoS) condition. The vulnerability is due to incorrect processing of certain IKEv2 packets. An attacker could exploit this vulnerability by sending crafted IKEv2 packets to an affected device to be processed. A successful exploit could cause an affected device to continuously consume memory and eventually reload, resulting in a DoS condition. Cisco Bug IDs: CSCvf22394. | |||||
| CVE-2018-0167 | 2 Cisco, Rockwellautomation | 18 Asr 9001, Asr 9006, Asr 9010 and 15 more | 2019-10-09 | 8.3 HIGH | 8.8 HIGH |
| Multiple Buffer Overflow vulnerabilities in the Link Layer Discovery Protocol (LLDP) subsystem of Cisco IOS Software, Cisco IOS XE Software, and Cisco IOS XR Software could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition or execute arbitrary code with elevated privileges on an affected device. Cisco Bug IDs: CSCuo17183, CSCvd73487. | |||||
| CVE-2018-0173 | 2 Cisco, Rockwellautomation | 20 4321 Integrated Services Router, 4331 Integrated Services Router, 4351 Integrated Services Router and 17 more | 2019-10-09 | 7.8 HIGH | 8.6 HIGH |
| A vulnerability in the Cisco IOS Software and Cisco IOS XE Software function that restores encapsulated option 82 information in DHCP Version 4 (DHCPv4) packets could allow an unauthenticated, remote attacker to cause an affected device to reload, resulting in a Relay Reply denial of service (DoS) condition. The vulnerability exists because the affected software performs incomplete input validation of encapsulated option 82 information that it receives in DHCPOFFER messages from DHCPv4 servers. An attacker could exploit this vulnerability by sending a crafted DHCPv4 packet to an affected device, which the device would then forward to a DHCPv4 server. When the affected software processes the option 82 information that is encapsulated in the response from the server, an error could occur. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a DoS condition. Cisco Bug IDs: CSCvg62754. | |||||
| CVE-2018-0175 | 2 Cisco, Rockwellautomation | 9 Ios, Ios Xe, Ios Xr and 6 more | 2019-10-09 | 7.9 HIGH | 8.0 HIGH |
| Format String vulnerability in the Link Layer Discovery Protocol (LLDP) subsystem of Cisco IOS Software, Cisco IOS XE Software, and Cisco IOS XR Software could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition or execute arbitrary code with elevated privileges on an affected device. Cisco Bug IDs: CSCvd73664. | |||||
| CVE-2017-7902 | 1 Rockwellautomation | 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed. | |||||
| CVE-2017-7924 | 1 Rockwellautomation | 8 1763-l16awa, 1763-l16awa Firmware, 1763-l16bbb and 5 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands (PCCC) packet to the controller that could potentially cause the controller to enter a DoS condition. | |||||
| CVE-2017-7914 | 1 Rockwellautomation | 2 Panelview Plus 6 700-1500, Panelview Plus 6 700-1500 Firmware | 2019-10-09 | 7.5 HIGH | 8.6 HIGH |
| A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access. | |||||
| CVE-2017-6024 | 1 Rockwellautomation | 4 Compactlogix 5830, Compactlogix 5830 Firmware, Controllogix 5580 and 1 more | 2019-10-09 | 7.1 HIGH | 5.9 MEDIUM |
| A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller. | |||||
| CVE-2017-6015 | 1 Rockwellautomation | 1 Factorytalk Activation | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later. | |||||
| CVE-2017-5176 | 1 Rockwellautomation | 8 9328-ccwdevdee, 9328-ccwdevene, 9328-ccwdevese and 5 more | 2019-10-09 | 6.2 MEDIUM | 7.0 HIGH |
| A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. | |||||
| CVE-2017-14022 | 1 Rockwellautomation | 1 Factorytalk Alarms And Events | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate. | |||||
