| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-30190 | 1 Codesys | 1 V2 Web Server | 2022-05-03 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. | |||||
| CVE-2019-5105 | 1 Codesys | 1 Codesys | 2022-04-29 | 5.0 MEDIUM | 7.5 HIGH |
| An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System). | |||||
| CVE-2021-21866 | 1 Codesys | 1 Development System | 2022-04-28 | 6.8 MEDIUM | 7.8 HIGH |
| A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. | |||||
| CVE-2021-21865 | 1 Codesys | 1 Development System | 2022-04-28 | 6.8 MEDIUM | 7.8 HIGH |
| A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. | |||||
| CVE-2021-21863 | 1 Codesys | 1 Development System | 2022-04-28 | 6.8 MEDIUM | 7.8 HIGH |
| A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. | |||||
| CVE-2021-21864 | 1 Codesys | 1 Development System | 2022-04-28 | 6.8 MEDIUM | 7.8 HIGH |
| A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. | |||||
| CVE-2021-21869 | 1 Codesys | 1 Codesys | 2022-04-28 | 6.8 MEDIUM | 7.8 HIGH |
| An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. | |||||
| CVE-2022-22516 | 2 Codesys, Microsoft | 5 Control Rte Sl, Control Rte Sl \(for Beckhoff Cx\), Control Win Sl and 2 more | 2022-04-28 | 7.2 HIGH | 7.8 HIGH |
| The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space. | |||||
| CVE-2022-22510 | 1 Codesys | 1 Profinet | 2022-02-04 | 5.0 MEDIUM | 7.5 HIGH |
| Codesys Profinet in version V4.2.0.0 is prone to null pointer dereference that allows a denial of service (DoS) attack of an unauthenticated user via SNMP. | |||||
| CVE-2021-34593 | 1 Codesys | 2 Plcwinnt, Runtime Toolkit | 2022-02-04 | 5.0 MEDIUM | 7.5 HIGH |
| In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC. | |||||
| CVE-2019-9009 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2022-01-01 | 5.0 MEDIUM | 7.5 HIGH |
| An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash. | |||||
| CVE-2021-29241 | 1 Codesys | 11 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 8 more | 2021-12-16 | 5.0 MEDIUM | 7.5 HIGH |
| CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS). | |||||
| CVE-2021-34585 | 1 Codesys | 1 Codesys | 2021-11-23 | 5.0 MEDIUM | 7.5 HIGH |
| In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests can trigger a parser error. Since the parser result is not checked under all conditions, a pointer dereference with an invalid address can occur. This leads to a denial of service situation. | |||||
| CVE-2021-34595 | 1 Codesys | 2 Plcwinnt, Runtime Toolkit | 2021-11-04 | 5.5 MEDIUM | 8.1 HIGH |
| A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite. | |||||
| CVE-2021-34596 | 1 Codesys | 2 Plcwinnt, Runtime Toolkit | 2021-11-04 | 4.0 MEDIUM | 6.5 MEDIUM |
| A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition. | |||||
| CVE-2021-34583 | 1 Codesys | 1 Codesys | 2021-10-28 | 5.0 MEDIUM | 7.5 HIGH |
| Crafted web server requests may cause a heap-based buffer overflow and could therefore trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22. | |||||
| CVE-2021-34586 | 1 Codesys | 1 Codesys | 2021-10-28 | 5.0 MEDIUM | 7.5 HIGH |
| In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests may cause a Null pointer dereference in the CODESYS web server and may result in a denial-of-service condition. | |||||
| CVE-2019-13548 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2021-10-28 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. | |||||
| CVE-2021-29242 | 1 Codesys | 22 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 19 more | 2021-09-14 | 7.5 HIGH | 7.3 HIGH |
| CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages. | |||||
| CVE-2021-33486 | 1 Codesys | 1 Runtime Toolkit | 2021-08-17 | 5.0 MEDIUM | 7.5 HIGH |
| All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions. | |||||
| CVE-2021-36763 | 1 Codesys | 7 Control, Control Rte, Control Runtime System Toolkit and 4 more | 2021-08-17 | 5.0 MEDIUM | 7.5 HIGH |
| In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. | |||||
| CVE-2021-33485 | 1 Codesys | 7 Control, Control Rte, Control Runtime System Toolkit and 4 more | 2021-08-17 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. | |||||
| CVE-2021-36764 | 1 Codesys | 1 Gateway | 2021-08-11 | 5.0 MEDIUM | 7.5 HIGH |
| In CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted communication requests may cause a Null pointer dereference in the affected CODESYS products and may result in a denial-of-service condition. | |||||
| CVE-2021-36765 | 1 Codesys | 1 Ethernetip | 2021-08-11 | 5.0 MEDIUM | 7.5 HIGH |
| In CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer dereference in the downloaded vulnerable EtherNet/IP stack that is executed by the CODESYS Control runtime system. | |||||
| CVE-2020-15806 | 1 Codesys | 16 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 13 more | 2021-07-21 | 5.0 MEDIUM | 7.5 HIGH |
| CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation. | |||||
| CVE-2020-7052 | 1 Codesys | 15 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 12 more | 2021-07-21 | 4.0 MEDIUM | 6.5 MEDIUM |
| CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition. | |||||
| CVE-2020-12068 | 1 Codesys | 12 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 9 more | 2021-07-21 | 6.4 MEDIUM | 6.5 MEDIUM |
| An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation. | |||||
| CVE-2019-13538 | 1 Codesys | 1 Codesys | 2021-06-09 | 6.8 MEDIUM | 8.6 HIGH |
| 3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only. | |||||
| CVE-2021-30187 | 1 Codesys | 1 Runtime Toolkit | 2021-05-26 | 4.6 MEDIUM | 5.3 MEDIUM |
| CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command. | |||||
| CVE-2021-30186 | 1 Codesys | 2 Plcwinnt, Runtime Toolkit | 2021-05-26 | 5.0 MEDIUM | 7.5 HIGH |
| CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow. | |||||
| CVE-2021-30195 | 1 Codesys | 2 Plcwinnt, Runtime Toolkit | 2021-05-26 | 5.0 MEDIUM | 7.5 HIGH |
| CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation. | |||||
| CVE-2021-30188 | 1 Codesys | 1 V2 Runtime System Sp | 2021-05-26 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. | |||||
| CVE-2021-30189 | 1 Codesys | 1 V2 Web Server | 2021-05-26 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow. | |||||
| CVE-2021-30191 | 1 Codesys | 1 V2 Web Server | 2021-05-26 | 5.0 MEDIUM | 7.5 HIGH |
| CODESYS V2 Web-Server before 1.1.9.20 has a a Buffer Copy without Checking the Size of the Input. | |||||
| CVE-2021-30193 | 1 Codesys | 1 V2 Web Server | 2021-05-26 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write. | |||||
| CVE-2021-30194 | 1 Codesys | 1 V2 Web Server | 2021-05-25 | 6.4 MEDIUM | 9.1 CRITICAL |
| CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Read. | |||||
| CVE-2021-29240 | 1 Codesys | 1 Development System | 2021-05-11 | 6.8 MEDIUM | 7.8 HIGH |
| The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content. | |||||
| CVE-2021-29238 | 1 Codesys | 1 Automation Server | 2021-05-11 | 6.8 MEDIUM | 8.8 HIGH |
| CODESYS Automation Server before 1.16.0 allows cross-site request forgery (CSRF). | |||||
| CVE-2021-29239 | 1 Codesys | 1 Development System | 2021-05-07 | 4.6 MEDIUM | 7.8 HIGH |
| CODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files embedded in libraries without first checking their validity. | |||||
| CVE-2018-20026 | 1 Codesys | 18 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 15 more | 2020-08-24 | 5.0 MEDIUM | 7.5 HIGH |
| Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0. | |||||
| CVE-2019-9010 | 1 Codesys | 10 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 7 more | 2020-08-24 | 7.5 HIGH | 9.8 CRITICAL |
| An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. | |||||
| CVE-2019-9012 | 1 Codesys | 10 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 7 more | 2020-08-24 | 7.8 HIGH | 7.5 HIGH |
| An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. | |||||
| CVE-2019-9013 | 1 Codesys | 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more | 2020-08-24 | 5.8 MEDIUM | 8.8 HIGH |
| An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3. | |||||
| CVE-2020-10245 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2020-04-01 | 10.0 HIGH | 9.8 CRITICAL |
| CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. | |||||
| CVE-2019-9008 | 1 Codesys | 10 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 7 more | 2020-03-11 | 6.5 MEDIUM | 8.8 HIGH |
| An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. | |||||
| CVE-2019-19789 | 1 Codesys | 3 Plcwinnt, Runtime Toolkit, Sp Realtime Nt | 2020-01-03 | 4.0 MEDIUM | 6.5 MEDIUM |
| 3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference. | |||||
| CVE-2019-18858 | 1 Codesys | 14 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 11 more | 2019-11-22 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. | |||||
| CVE-2019-16265 | 1 Codesys | 2 Codesys, Eni Server | 2019-10-28 | 7.5 HIGH | 9.8 CRITICAL |
| CODESYS V2.3 ENI server up to V3.2.2.24 has a Buffer Overflow. | |||||
| CVE-2019-13532 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. | |||||
| CVE-2019-13542 | 1 Codesys | 10 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 7 more | 2019-10-09 | 4.0 MEDIUM | 6.5 MEDIUM |
| 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. | |||||