Search
Total
201818 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-7927 | 1 Dahuasecurity | 30 Ddh-hcvr4xxx, Dh-hcvr4xxx Firmware, Dh-hcvr5xxx and 27 more | 2019-10-09 | 7.5 HIGH | 7.3 HIGH |
| A Use of Password Hash Instead of Password for Authentication issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The use of password hash instead of password for authentication vulnerability was identified, which could allow a malicious user to bypass authentication without obtaining the actual password. | |||||
| CVE-2017-7928 | 1 Selinc | 4 Sel-3620, Sel-3620 Firmware, Sel-3622 and 1 more | 2019-10-09 | 7.5 HIGH | 10.0 CRITICAL |
| An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may allow for unauthorized communications to downstream devices. | |||||
| CVE-2017-7929 | 1 Advantech | 1 Webaccess | 2019-10-09 | 5.5 MEDIUM | 7.1 HIGH |
| An Absolute Path Traversal issue was discovered in Advantech WebAccess Version 8.1 and prior. The absolute path traversal vulnerability has been identified, which may allow an attacker to traverse the file system to access restricted files or directories. | |||||
| CVE-2017-7930 | 1 Osisoft | 1 Pi Data Archive | 2019-10-09 | 5.8 MEDIUM | 7.4 HIGH |
| An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Data Archive has protocol flaws with the potential to expose change records in the clear and allow a malicious party to spoof a server within a collective. | |||||
| CVE-2017-5147 | 1 Azeotech | 1 Daqfactory | 2019-10-09 | 4.6 MEDIUM | 5.3 MEDIUM |
| An Uncontrolled Search Path Element issue was discovered in AzeoTech DAQFactory versions prior to 17.1. An uncontrolled search path element vulnerability has been identified, which may execute malicious DLL files that have been placed within the search path. | |||||
| CVE-2017-5170 | 1 Moxa | 1 Softnvr-ia Live View | 2019-10-09 | 6.5 MEDIUM | 7.2 HIGH |
| An Uncontrolled Search Path Element issue was discovered in Moxa SoftNVR-IA Live Viewer, Version 3.30.3122 and prior versions. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. The attacker needs to have administrative access to the default install location in order to plant the insecure DLL. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. | |||||
| CVE-2017-5175 | 1 Advantech | 1 Webaccess | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| Advantech WebAccess 8.1 and earlier contains a DLL hijacking vulnerability which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code. | |||||
| CVE-2017-5176 | 1 Rockwellautomation | 8 9328-ccwdevdee, 9328-ccwdevene, 9328-ccwdevese and 5 more | 2019-10-09 | 6.2 MEDIUM | 7.0 HIGH |
| A DLL Hijack issue was discovered in Rockwell Automation Connected Components Workbench (CCW). The following versions are affected: Connected Components Workbench - Developer Edition, v9.01.00 and earlier: 9328-CCWDEVENE, 9328-CCWDEVZHE, 9328-CCWDEVFRE, 9328-CCWDEVITE, 9328-CCWDEVDEE, 9328-CCWDEVESE, and 9328-CCWDEVPTE; and Connected Components Workbench - Free Standard Edition (All Supported Languages), v9.01.00 and earlier. Certain DLLs included with versions of CCW software can be potentially hijacked to allow an attacker to gain rights to a victim's affected personal computer. Such access rights can be at the same or potentially higher level of privileges as the compromised user account, including and up to computer administrator privileges. | |||||
| CVE-2017-5187 | 1 Microfocus | 4 Directory Server, Enterprise Developer, Enterprise Server and 1 more | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| A Cross-Site Request Forgery (CWE-352) vulnerability in Directory Server (aka Enterprise Server Administration web UI) in Micro Focus Enterprise Developer and Enterprise Server 2.3 and earlier, 2.3 Update 1 before Hotfix 8, and 2.3 Update 2 before Hotfix 9 allows remote unauthenticated attackers to view and alter (CWE-275) configuration information and inject OS commands (CWE-78) via forged requests. | |||||
| CVE-2017-5188 | 1 Opensuse | 1 Open Build Service | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| The bs_worker code in open build service before 20170320 followed relative symlinks, allowing reading of files outside of the package source directory during build, allowing leakage of private information. | |||||
| CVE-2017-5189 | 1 Netiq | 1 Imanager | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance. | |||||
| CVE-2017-5243 | 1 Rapid7 | 1 Nexpose | 2019-10-09 | 6.8 MEDIUM | 8.5 HIGH |
| The default SSH configuration in Rapid7 Nexpose hardware appliances shipped before June 2017 does not specify desired algorithms for key exchange and other important functions. As a result, it falls back to allowing ALL algorithms supported by the relevant version of OpenSSH and makes the installations vulnerable to a range of MITM, downgrade, and decryption attacks. | |||||
| CVE-2017-5244 | 1 Rapid7 | 1 Metasploit | 2019-10-09 | 3.5 LOW | 3.5 LOW |
| Routes used to stop running Metasploit tasks (either particular ones or all tasks) allowed GET requests. Only POST requests should have been allowed, as the stop/stop_all routes change the state of the service. This could have allowed an attacker to stop currently-running Metasploit tasks by getting an authenticated user to execute JavaScript. As of Metasploit 4.14.0 (Update 2017061301), the routes for stopping tasks only allow POST requests, which validate the presence of a secret token to prevent CSRF attacks. | |||||
| CVE-2017-5249 | 1 Wink | 1 Wink | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| In version 6.1.0.19 and prior of Wink Labs's Wink - Smart Home Android app, the OAuth token used by the app to authorize user access is not stored in an encrypted and secure manner. | |||||
| CVE-2017-5250 | 1 Insteon | 1 Insteon For Hub | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| In version 1.9.7 and prior of Insteon's Insteon for Hub Android app, the OAuth token used by the app to authorize user access is not stored in an encrypted and secure manner. | |||||
| CVE-2017-5251 | 1 Insteon | 2 Insteon Hub, Insteon Hub Firmware | 2019-10-09 | 6.8 MEDIUM | 8.1 HIGH |
| In version 1012 and prior of Insteon's Insteon Hub, the radio transmissions used for communication between the hub and connected devices are not encrypted. | |||||
| CVE-2017-5254 | 1 Cambiumnetworks | 4 Epmp 1000, Epmp 1000 Firmware, Epmp 2000 and 1 more | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| In version 3.5 and prior of Cambium Networks ePMP firmware, the non-administrative users 'installer' and 'home' have the capability of changing passwords for other accounts, including admin, after disabling a client-side protection mechanism. | |||||
| CVE-2017-5255 | 1 Cambiumnetworks | 4 Epmp 1000, Epmp 1000 Firmware, Epmp 2000 and 1 more | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| In version 3.5 and prior of Cambium Networks ePMP firmware, a lack of input sanitation for certain parameters on the web management console allows any authenticated user (including the otherwise low-privilege readonly user) to inject shell meta-characters as part of a specially-crafted POST request to the get_chart function and run OS-level commands, effectively as root. | |||||
| CVE-2017-5256 | 1 Cambiumnetworks | 4 Epmp 1000, Epmp 1000 Firmware, Epmp 2000 and 1 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| In version 3.5 and prior of Cambium Networks ePMP firmware, all authenticated users have the ability to update the Device Name and System Description fields in the web administration console, and those fields are vulnerable to persistent cross-site scripting (XSS) injection. | |||||
| CVE-2017-5257 | 1 Cambiumnetworks | 4 Epmp 1000, Epmp 1000 Firmware, Epmp 2000 and 1 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| In version 3.5 and prior of Cambium Networks ePMP firmware, an attacker who knows (or guesses) the SNMP read/write (RW) community string can insert XSS strings in certain SNMP OIDs which will execute in the context of the currently-logged on user. | |||||
| CVE-2017-5258 | 1 Cambiumnetworks | 4 Epmp 1000, Epmp 1000 Firmware, Epmp 2000 and 1 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| In version 3.5 and prior of Cambium Networks ePMP firmware, an attacker who knows or can guess the RW community string can provide a URL for a configuration file over SNMP with XSS strings in certain SNMP OIDs, serve it via HTTP, and the affected device will perform a configuration restore using the attacker's supplied config file, including the inserted XSS strings. | |||||
| CVE-2017-5259 | 1 Cambiumnetworks | 10 Cnpilot E400, Cnpilot E400 Firmware, Cnpilot E410 and 7 more | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://<device-ip-or-hostname>/adm/syscmd.asp. | |||||
| CVE-2017-5260 | 1 Cambiumnetworks | 10 Cnpilot E400, Cnpilot E400 Firmware, Cnpilot E410 and 7 more | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, although the option to access the configuration file is not available in the normal web administrative console for the 'user' account, the configuration file is accessible via direct object reference (DRO) at http://<device-ip-or-hostname>/goform/down_cfg_file by this otherwise low privilege 'user' account. | |||||
| CVE-2017-5261 | 1 Cambiumnetworks | 10 Cnpilot E400, Cnpilot E400 Firmware, Cnpilot E410 and 7 more | 2019-10-09 | 4.0 MEDIUM | 8.8 HIGH |
| In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the 'ping' and 'traceroute' functions of the web administrative console expose a file path traversal vulnerability, accessible to all authenticated users. | |||||
| CVE-2017-5262 | 1 Cambiumnetworks | 10 Cnpilot E400, Cnpilot E400 Firmware, Cnpilot E410 and 7 more | 2019-10-09 | 7.7 HIGH | 8.0 HIGH |
| In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the SNMP read-only (RO) community string has access to sensitive information by OID reference. | |||||
| CVE-2017-5263 | 1 Cambiumnetworks | 10 Cnpilot E400, Cnpilot E400 Firmware, Cnpilot E410 and 7 more | 2019-10-09 | 5.4 MEDIUM | 8.0 HIGH |
| Versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware lack CSRF controls that can mitigate the effects of CSRF attacks, which are most typically implemented as randomized per-session tokens associated with any web application function, especially destructive ones. | |||||
| CVE-2017-5530 | 1 Tibco | 1 Tibbr | 2019-10-09 | 5.5 MEDIUM | 8.1 HIGH |
| The tibbr web server components of tibbr Community, and tibbr Enterprise contain SAML protocol handling errors which may allow authorized users to impersonate other users, and therefore escalate their access privileges. Affected releases are tibbr Community 5.2.1 and below; 6.0.0; 6.0.1; 7.0.0, tibbr Enterprise 5.2.1 and below; 6.0.0; 6.0.1; 7.0.0. | |||||
| CVE-2017-5531 | 1 Tibco | 2 Managed File Transfer Command Center, Managed File Transfer Internet Server | 2019-10-09 | 6.5 MEDIUM | 8.8 HIGH |
| Deployments of TIBCO Managed File Transfer Command Center versions 8.0.0 and 8.0.1 and TIBCO Managed File Transfer Internet Server versions 8.0.0 and 8.0.1 that enable the Administrator Service may be affected by a vulnerability which may allow any authenticated user to gain administrative control of Managed File Transfer web applications. | |||||
| CVE-2017-5532 | 1 Tibco | 5 Jasperreports Library, Jasperreports Server, Jaspersoft and 2 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| A vulnerability in the report renderer component of TIBCO JasperReports Server, TIBCO JasperReports Server Community Edition, TIBCO JasperReports Server for ActiveMatrix BPM, TIBCO JasperReports Library, TIBCO JasperReports Library for ActiveMatrix BPM, TIBCO Jaspersoft for AWS with Multi-Tenancy, TIBCO Jaspersoft Reporting and Analytics for AWS, TIBCO Jaspersoft Studio, and TIBCO Jaspersoft Studio for ActiveMatrix BPM may allow a subset of authorized users to perform persistent cross-site scripting (XSS) attacks. Affected releases are TIBCO JasperReports Server 6.2.3 and below; 6.3.0; 6.3.1; 6.3.2; 6.4.0, TIBCO JasperReports Server Community Edition 6.4.0 and below, TIBCO JasperReports Server for ActiveMatrix BPM 6.4.0 and below, TIBCO JasperReports Library 6.2.3 and below; 6.3.0; 6.3.1; 6.3.2; 6.4.0; 6.4.1, TIBCO JasperReports Library for ActiveMatrix BPM 6.4.1 and below, TIBCO Jaspersoft for AWS with Multi-Tenancy 6.4.0 and below, TIBCO Jaspersoft Reporting and Analytics for AWS 6.4.0 and below, TIBCO Jaspersoft Studio 6.2.3 and below; 6.3.0; 6.3.1; 6.3.2; 6.4.0, and TIBCO Jaspersoft Studio for ActiveMatrix BPM 6.4.0 and below. | |||||
| CVE-2017-5534 | 1 Tibco | 1 Tibbr | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| The tibbr user profiles components of tibbr Community, and tibbr Enterprise expose a weakness in an improperly sandboxed third-party component. Affected releases are TIBCO Software Inc. tibbr Community 5.2.1 and below; 6.0.0; 6.0.1; 7.0.0, tibbr Enterprise 5.2.1 and below; 6.0.0; 6.0.1; 7.0.0. | |||||
| CVE-2017-5535 | 1 Tibco | 1 Datasynapse Gridserver Manager | 2019-10-09 | 4.3 MEDIUM | 6.8 MEDIUM |
| The GridServer Broker, GridServer Driver, and GridServer Engine components of TIBCO Software Inc. TIBCO DataSynapse GridServer Manager contain vulnerabilities related to both the improper use of encryption mechanisms and the use of weak ciphers. A malicious actor could theoretically compromise the traffic between any of the components. Affected releases include TIBCO Software Inc.'s TIBCO DataSynapse GridServer Manager: versions up to and including 5.1.3; 6.0.0; 6.0.1; 6.0.2; 6.1.0; 6.1.1; and 6.2.0. | |||||
| CVE-2017-5536 | 1 Tibco | 1 Datasynapse Gridserver Manager | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| The GridServer Broker, and GridServer Director components of TIBCO Software Inc. TIBCO DataSynapse GridServer Manager contain vulnerabilities which may allow an authenticated user to perform cross-site scripting (XSS). In addition, an authenticated user could be a victim of a cross-site request forgery (CSRF) attack. Affected releases include TIBCO Software Inc.'s TIBCO DataSynapse GridServer Manager: versions up to and including 5.1.3; 6.0.0; 6.0.1; 6.0.2; 6.1.0; 6.1.1; and 6.2.0. | |||||
| CVE-2017-6015 | 1 Rockwellautomation | 1 Factorytalk Activation | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later. | |||||
| CVE-2017-6016 | 1 Leao Consultoria E Desenvolvimento De Sistemas | 1 Ltda Me Laquis Scada | 2019-10-09 | 4.4 MEDIUM | 7.3 HIGH |
| An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges. | |||||
| CVE-2017-6018 | 1 Bbraun | 2 Spacestation, Station Firmware | 2019-10-09 | 5.8 MEDIUM | 6.1 MEDIUM |
| An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input. | |||||
| CVE-2017-6020 | 1 Lcds | 1 Laquis Scada | 2019-10-09 | 4.0 MEDIUM | 5.3 MEDIUM |
| Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level. | |||||
| CVE-2017-6021 | 2 Aveva, Schneider-electric | 2 Clearscada, Clearscada | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | |||||
| CVE-2017-6022 | 1 Bd | 2 Kla Journal Service, Performa | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. | |||||
| CVE-2017-6024 | 1 Rockwellautomation | 4 Compactlogix 5830, Compactlogix 5830 Firmware, Controllogix 5580 and 1 more | 2019-10-09 | 7.1 HIGH | 5.9 MEDIUM |
| A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller. | |||||
| CVE-2017-6025 | 1 Codesys | 1 Web Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code. | |||||
| CVE-2017-6027 | 1 Codesys | 1 Web Server | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution. | |||||
| CVE-2017-6029 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution. | |||||
| CVE-2017-6031 | 1 Certec Edv Gmbh | 1 Atvise Scada | 2019-10-09 | 6.8 MEDIUM | 8.8 HIGH |
| A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution. | |||||
| CVE-2017-6032 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
| A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. | |||||
| CVE-2017-6033 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. | |||||
| CVE-2017-6034 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. | |||||
| CVE-2017-6035 | 1 We-con | 1 Levi Studio Hmi Editor | 2019-10-09 | 9.3 HIGH | 8.8 HIGH |
| A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system. | |||||
| CVE-2017-6036 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2019-10-09 | 4.3 MEDIUM | 6.5 MEDIUM |
| A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination. | |||||
| CVE-2017-6037 | 1 We-con | 1 Levi Studio Hmi Editor | 2019-10-09 | 9.3 HIGH | 8.8 HIGH |
| A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow when a maliciously crafted project file is run by the system. | |||||
| CVE-2017-6038 | 1 Belden Hirschmann | 2 Gecko Lite Managed Switch, Gecko Lite Managed Switch Firmware | 2019-10-09 | 5.8 MEDIUM | 7.1 HIGH |
| A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request. | |||||