Filtered by vendor Schneider-electric
Subscribe
Search
Total
616 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2018-7817 | 1 Schneider-electric | 1 Zelio Soft 2 | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| A Use After Free (CWE-416) vulnerability exists in Zelio Soft 2 v5.1 and prior versions which could cause remote code execution when opening a specially crafted Zelio Soft project file. | |||||
| CVE-2018-7834 | 1 Schneider-electric | 2 Tsxetg100, Tsxetg100 Firmware | 2019-10-09 | 4.3 MEDIUM | 6.1 MEDIUM |
| A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user. | |||||
| CVE-2018-7820 | 1 Schneider-electric | 8 Ap9630, Ap9630 Firmware, Ap9631 and 5 more | 2019-10-09 | 5.0 MEDIUM | 9.8 CRITICAL |
| A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled. | |||||
| CVE-2018-7522 | 1 Schneider-electric | 2 Triconex Tricon Mp 3008, Triconex Tricon Mp 3008 Firmware | 2019-10-09 | 7.2 HIGH | 6.7 MEDIUM |
| In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states. | |||||
| CVE-2017-9637 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2019-10-09 | 1.9 LOW | 4.1 MEDIUM |
| Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||
| CVE-2017-7968 | 1 Schneider-electric | 1 Wonderware Indusoft Web Studio | 2019-10-09 | 7.2 HIGH | 7.8 HIGH |
| An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges. | |||||
| CVE-2017-9635 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2019-10-09 | 1.9 LOW | 3.9 LOW |
| Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||
| CVE-2017-6021 | 2 Aveva, Schneider-electric | 2 Clearscada, Clearscada | 2019-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | |||||
| CVE-2017-6032 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
| A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. | |||||
| CVE-2017-6034 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
| An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. | |||||
| CVE-2017-6033 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2019-10-09 | 6.8 MEDIUM | 7.8 HIGH |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. | |||||
| CVE-2017-13997 | 1 Schneider-electric | 2 Wonderware Indusoft Web Studio, Wonderware Intouch | 2019-10-09 | 10.0 HIGH | 9.8 CRITICAL |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. | |||||
| CVE-2015-6462 | 1 Schneider-electric | 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser. | |||||
| CVE-2015-6461 | 1 Schneider-electric | 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more | 2019-10-09 | 5.5 MEDIUM | 5.4 MEDIUM |
| Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. | |||||
| CVE-2015-1014 | 1 Schneider-electric | 3 Citectscada, Opc Factory Server, Scada Expert Vijeo Citect | 2019-10-09 | 4.4 MEDIUM | 7.3 HIGH |
| A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version. | |||||
| CVE-2017-5155 | 1 Schneider-electric | 1 Wonderware Historian | 2019-10-03 | 7.5 HIGH | 7.3 HIGH |
| An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well. | |||||
| CVE-2018-7785 | 1 Schneider-electric | 1 U.motion Builder | 2019-10-03 | 7.5 HIGH | 9.8 CRITICAL |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass. | |||||
| CVE-2018-7782 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2019-10-03 | 4.0 MEDIUM | 8.8 HIGH |
| In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text. | |||||
| CVE-2018-7770 | 1 Schneider-electric | 1 U.motion | 2019-10-03 | 4.3 MEDIUM | 6.5 MEDIUM |
| The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address. | |||||
| CVE-2018-7781 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2019-10-03 | 4.0 MEDIUM | 8.8 HIGH |
| In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation. | |||||
| CVE-2018-7246 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2019-10-03 | 5.0 MEDIUM | 9.8 CRITICAL |
| A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext | |||||
| CVE-2018-7245 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2019-10-03 | 6.4 MEDIUM | 9.1 CRITICAL |
| An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization. | |||||
| CVE-2018-7243 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2019-10-03 | 10.0 HIGH | 9.8 CRITICAL |
| An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system. | |||||
| CVE-2018-7240 | 1 Schneider-electric | 26 140cpu31110, 140cpu31110 Firmware, 140cpu31110c and 23 more | 2019-10-03 | 6.5 MEDIUM | 8.8 HIGH |
| A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware. | |||||
| CVE-2017-9969 | 1 Schneider-electric | 1 Igss Mobile | 2019-10-03 | 2.1 LOW | 6.7 MEDIUM |
| An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information. | |||||
| CVE-2017-9967 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2019-10-03 | 4.6 MEDIUM | 7.8 HIGH |
| A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security. | |||||
| CVE-2017-9966 | 1 Schneider-electric | 1 Pelco Videoxpert | 2019-10-03 | 7.1 HIGH | 7.1 HIGH |
| A privilege escalation vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. By replacing certain files, an unauthorized user can obtain system privileges and the inserted code would execute at an elevated privilege level. | |||||
| CVE-2017-9961 | 1 Schneider-electric | 1 Pro-face Gp Pro Ex | 2019-10-03 | 4.6 MEDIUM | 7.8 HIGH |
| A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process. | |||||
| CVE-2017-9959 | 1 Schneider-electric | 1 U.motion Builder | 2019-10-03 | 4.9 MEDIUM | 5.5 MEDIUM |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition. | |||||
| CVE-2017-9958 | 1 Schneider-electric | 1 U.motion Builder | 2019-10-03 | 7.2 HIGH | 7.8 HIGH |
| An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an improper handling of the system configuration can allow an attacker to execute arbitrary code under the context of root. | |||||
| CVE-2017-8371 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2019-10-03 | 4.0 MEDIUM | 6.8 MEDIUM |
| Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors. | |||||
| CVE-2017-7972 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2019-10-03 | 5.2 MEDIUM | 5.5 MEDIUM |
| A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes. | |||||
| CVE-2017-7970 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2019-10-03 | 3.3 LOW | 6.5 MEDIUM |
| A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components. | |||||
| CVE-2017-7966 | 1 Schneider-electric | 1 Somachine | 2019-10-03 | 6.8 MEDIUM | 8.8 HIGH |
| A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL. | |||||
| CVE-2019-6810 | 1 Schneider-electric | 2 Bmxnor0200h, Bmxnor0200h Firmware | 2019-10-02 | 6.5 MEDIUM | 8.8 HIGH |
| CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol. | |||||
| CVE-2019-6831 | 1 Schneider-electric | 2 Bmxnor0200h, Bmxnor0200h Firmware | 2019-10-02 | 5.0 MEDIUM | 8.6 HIGH |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP. | |||||
| CVE-2018-7811 | 1 Schneider-electric | 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more | 2019-10-02 | 5.0 MEDIUM | 9.8 CRITICAL |
| An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password function of the web server | |||||
| CVE-2019-6812 | 1 Schneider-electric | 2 Bmx-nor-0200h, Bmx-nor-0200h Firmware | 2019-09-30 | 4.0 MEDIUM | 7.2 HIGH |
| A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol. | |||||
| CVE-2018-7784 | 1 Schneider-electric | 1 U.motion | 2019-09-30 | 7.5 HIGH | 9.8 CRITICAL |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application. | |||||
| CVE-2018-1126 | 5 Canonical, Debian, Procps-ng Project and 2 more | 10 Ubuntu Linux, Debian Linux, Procps-ng and 7 more | 2019-07-30 | 7.5 HIGH | 9.8 CRITICAL |
| procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124. | |||||
| CVE-2019-6822 | 1 Schneider-electric | 1 Zelio Soft 2 | 2019-07-22 | 6.8 MEDIUM | 7.8 HIGH |
| A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file. | |||||
| CVE-2019-6827 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2019-07-22 | 6.8 MEDIUM | 7.8 HIGH |
| A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated. | |||||
| CVE-2018-7839 | 1 Schneider-electric | 1 Iiot Monitor | 2019-06-07 | 2.1 LOW | 5.5 MEDIUM |
| A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure. | |||||
| CVE-2018-7832 | 1 Schneider-electric | 1 Pro-face Gp-pro Ex | 2019-05-28 | 6.5 MEDIUM | 8.8 HIGH |
| An Improper Input Validation vulnerability exists in Pro-Face GP-Pro EX v4.08 and previous versions which could cause the execution arbitrary executable when GP-Pro EX is launched. | |||||
| CVE-2018-7825 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2019-05-28 | 6.5 MEDIUM | 8.8 HIGH |
| A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands. | |||||
| CVE-2018-7826 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2019-05-28 | 6.5 MEDIUM | 8.8 HIGH |
| A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands. | |||||
| CVE-2018-7828 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2019-05-28 | 6.8 MEDIUM | 8.8 HIGH |
| A Cross-Site Request Forgery (CSRF) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera when an authenticated user clicks a specially crafted malicious link while logged into the camera. | |||||
| CVE-2018-7780 | 1 Schneider-electric | 40 Ibp1110-1er, Ibp1110-1er Firmware, Ibp219-1er and 37 more | 2019-05-24 | 7.5 HIGH | 9.8 CRITICAL |
| In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set". | |||||
| CVE-2018-7829 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2019-05-24 | 9.0 HIGH | 8.8 HIGH |
| An Improper Neutralization of Special Elements in Query vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which allows an attacker to execute arbitrary system commands. | |||||
| CVE-2019-6816 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2019-05-23 | 6.4 MEDIUM | 9.1 CRITICAL |
| In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. | |||||