CVE-2020-16220 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2023-12-12 3.3 LOW 4.3 MEDIUM
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
CVE-2020-16216 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2023-12-12 6.1 MEDIUM 6.5 MEDIUM
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
CVE-2020-16224 1 Philips 1 Patient Information Center Ix 2023-12-12 3.3 LOW 6.5 MEDIUM
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.
CVE-2020-16228 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2023-12-12 5.2 MEDIUM 6.4 MEDIUM
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
CVE-2020-16214 1 Philips 1 Patient Information Center Ix 2023-12-12 5.8 MEDIUM 5.0 MEDIUM
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.
CVE-2020-16212 1 Philips 1 Patient Information Center Ix 2023-12-12 4.6 MEDIUM 6.8 MEDIUM
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
CVE-2021-27493 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2022-07-12 6.4 MEDIUM 6.5 MEDIUM
Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component.
CVE-2018-14789 1 Philips 2 Intellispace Cardiovascular, Xcelera 2022-02-09 4.6 MEDIUM 6.7 MEDIUM
In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges.
CVE-2021-23173 1 Philips 1 Engage 2022-01-14 4.0 MEDIUM 4.3 MEDIUM
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data.
CVE-2021-43552 1 Philips 1 Patient Information Center Ix 2022-01-12 2.1 LOW 5.5 MEDIUM
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.
CVE-2021-43550 1 Philips 3 Efficia Cm, Efficia Cm Firmware, Patient Information Center Ix 2022-01-12 3.3 LOW 6.5 MEDIUM
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.
CVE-2021-43548 1 Philips 1 Patient Information Center Ix 2022-01-12 3.3 LOW 6.5 MEDIUM
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2021-42744 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2021-11-23 2.1 LOW 5.5 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x exposes sensitive information to an actor not explicitly authorized to have access.
CVE-2021-26262 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2021-11-23 5.0 MEDIUM 5.5 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CVE-2021-26248 1 Philips 4 Mri 1.5t, Mri 1.5t Firmware, Mri 3t and 1 more 2021-11-23 2.1 LOW 5.5 MEDIUM
Philips MRI 1.5T and MRI 3T Version 5.x.x assigns an owner who is outside the intended control sphere to a resource.
CVE-2018-10599 1 Philips 36 Avalon Fetal\/maternal Monitors Fm20, Avalon Fetal\/maternal Monitors Fm20 Firmware, Avalon Fetal\/maternal Monitors Fm30 and 33 more 2021-05-10 2.9 LOW 5.3 MEDIUM
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
CVE-2020-27298 1 Philips 5 Coronary Tools, Dynamic Coronary Roadmap, Interventional Workspot and 2 more 2021-02-02 3.3 LOW 6.5 MEDIUM
Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.
CVE-2019-10968 1 Philips 1 Zymed Holter 2010 2020-10-01 2.1 LOW 4.4 MEDIUM
Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled.
CVE-2020-16200 1 Philips 1 Clinical Collaboration Platform 2020-09-25 3.3 LOW 6.5 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.
CVE-2020-16198 1 Philips 1 Clinical Collaboration Platform 2020-09-25 5.8 MEDIUM 6.3 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. When an attacker claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-14506 1 Philips 1 Clinical Collaboration Platform 2020-09-25 4.3 MEDIUM 4.3 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2020-11617 2 Philips, Thomsonstb 4 Dtr3502bfta Dvb-t2, Dtr3502bfta Dvb-t2 Firmware, Tht741fta and 1 more 2020-09-09 4.3 MEDIUM 5.9 MEDIUM
The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client.
CVE-2020-14518 1 Philips 1 Dreammapper 2020-08-27 5.0 MEDIUM 5.3 MEDIUM
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.
CVE-2020-16239 1 Philips 2 Suresigns Vs4, Suresigns Vs4 Firmware 2020-08-27 4.0 MEDIUM 4.9 MEDIUM
Philips SureSigns VS4, A.07.107 and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-14477 1 Philips 16 Affiniti 50, Affiniti 50 Firmware, Affiniti 70 and 13 more 2020-07-15 3.6 LOW 4.4 MEDIUM
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.
CVE-2020-12023 1 Philips 1 Intellibridge Enterprise 2020-06-23 2.7 LOW 4.5 MEDIUM
Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Enterprise Systems, are logged as the payload in IntelliBridge Enterprise (IBE) within the transaction logs. An attacker with administrative privileges could exploit this vulnerability to read plain text credentials from log files.
CVE-2019-18263 1 Philips 6 Endura, Endura Firmware, Pulsera and 3 more 2020-01-10 3.3 LOW 6.5 MEDIUM
An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016-August 2018), Veradius Unity (718132) with ViewForum option (shipped between 2016-August 2018), Pulsera (718095) and Endura (718075) with wireless option (shipped between 26-June-2017 through 07-August 2018), Pulsera (718095) and Endura (718075) with ViewForum option (shipped between 26-June-2017 through 07-August 2018). The router software uses an encryption scheme that is not strong enough for the level of protection required.
CVE-2019-18241 1 Philips 4 Intellibridge Ec40, Intellibridge Ec40 Firmware, Intellibridge Ec80 and 1 more 2019-12-18 3.3 LOW 6.5 MEDIUM
In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. This could enable an unauthorized attacker with access to the network to capture and replay the session and gain unauthorized access to the EC40/80 hub.
CVE-2019-13557 1 Philips 2 Tasy Emr, Tasy Webportal 2019-11-13 5.0 MEDIUM 5.3 MEDIUM
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.
CVE-2019-13546 1 Philips 1 Intellispace Perinatal 2019-10-30 7.2 HIGH 6.8 MEDIUM
In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the application and access unauthorized resources from the Windows operating system as the limited-access Windows user. Due to potential Windows vulnerabilities, it may be possible for additional attack methods to be used to escalate privileges on the operating system.
CVE-2019-6562 1 Philips 1 Tasy Emr 2019-10-09 3.5 LOW 5.4 MEDIUM
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
CVE-2018-8846 1 Philips 1 E-alert Firmware 2019-10-09 4.3 MEDIUM 6.1 MEDIUM
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.
CVE-2018-19001 1 Philips 1 Healthsuite Health 2019-10-09 4.6 MEDIUM 4.3 MEDIUM
Philips HealthSuite Health Android App, all versions. The software uses simple encryption that is not strong enough for the level of protection required.
CVE-2018-14801 1 Philips 10 Pagewriter Tc10, Pagewriter Tc10 Firmware, Pagewriter Tc20 and 7 more 2019-10-09 7.2 HIGH 6.2 MEDIUM
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.
CVE-2018-14803 1 Philips 2 E-alert, E-alert Firmware 2019-10-09 5.0 MEDIUM 5.3 MEDIUM
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to the attacker, but might be useful information in an attack.
CVE-2017-9657 1 Philips 2 Intellivue Mx40, Intellivue Mx40 Firmware 2019-10-09 3.3 LOW 6.5 MEDIUM
Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
CVE-2017-9658 1 Philips 2 Intellivue Mx40, Intellivue Mx40 Firmware 2019-10-09 6.1 MEDIUM 6.5 MEDIUM
Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
CVE-2018-5438 1 Philips 1 Intellispace Cardiovascular 2018-04-20 3.3 LOW 6.3 MEDIUM
Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.
CVE-2015-2883 1 Philips 1 In.sight B120\\37 2017-04-14 3.5 LOW 5.4 MEDIUM
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.