Vulnerabilities (CVE)

Filtered by vendor Paessler Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-31448 1 Paessler 1 Prtg Network Monitor 2023-08-16 N/A 4.7 MEDIUM
A path traversal vulnerability was identified in the HL7 sensor in PRTG 23.2.84.1566 and earlier versions where an authenticated user with write permissions could trick the HL7 sensor into behaving differently for existing files and non-existing files. This made it possible to traverse paths, allowing the sensor to execute files outside the designated custom sensors folder. The severity of this vulnerability is medium and received a score of 4.7 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
CVE-2023-31449 1 Paessler 1 Prtg Network Monitor 2023-08-16 N/A 4.7 MEDIUM
A path traversal vulnerability was identified in the WMI Custom sensor in PRTG 23.2.84.1566 and earlier versions where an authenticated user with write permissions could trick the WMI Custom sensor into behaving differently for existing files and non-existing files. This made it possible to traverse paths, allowing the sensor to execute files outside the designated custom sensors folder. The severity of this vulnerability is medium and received a score of 4.7 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
CVE-2023-31450 1 Paessler 1 Prtg Network Monitor 2023-08-16 N/A 4.7 MEDIUM
A path traversal vulnerability was identified in the SQL v2 sensors in PRTG 23.2.84.1566 and earlier versions where an authenticated user with write permissions could trick the SQL v2 sensors into behaving differently for existing files and non-existing files. This made it possible to traverse paths, allowing the sensor to execute files outside the designated custom sensors folder. The severity of this vulnerability is medium and received a score of 4.7 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
CVE-2022-35739 1 Paessler 1 Prtg Network Monitor 2023-08-08 N/A 5.3 MEDIUM
PRTG Network Monitor through 22.2.77.2204 does not prevent custom input for a device’s icon, which can be modified to insert arbitrary content into the style tag for that device. When the device page loads, the arbitrary Cascading Style Sheets (CSS) data is inserted into the style tag, loading malicious content. Due to PRTG Network Monitor preventing “characters, and from modern browsers disabling JavaScript support in style tags, this vulnerability could not be escalated into a Cross-Site Scripting vulnerability.
CVE-2021-29643 1 Paessler 1 Prtg Network Monitor 2021-09-22 3.5 LOW 5.4 MEDIUM
PRTG Network Monitor before 21.3.69.1333 allows stored XSS via an unsanitized string imported from a User Object in a connected Active Directory instance.
CVE-2019-19119 1 Paessler 1 Prtg Network Monitor 2021-07-21 2.1 LOW 5.5 MEDIUM
An issue was discovered in PRTG 7.x through 19.4.53. Due to insufficient access control on local registry keys for the Core Server Service, a non-administrative user on the local machine is able to access administrative credentials.
CVE-2016-5078 1 Paessler 1 Prtg Network Monitor 2021-06-29 4.3 MEDIUM 6.1 MEDIUM
Paessler PRTG before 16.2.24.4045 has XSS via SNMP.
CVE-2018-14683 1 Paessler 1 Prtg Network Monitor 2021-06-29 4.3 MEDIUM 6.1 MEDIUM
PRTG before 19.1.49.1966 has Cross Site Scripting (XSS) in the WEBGUI.
CVE-2021-34547 1 Paessler 1 Prtg Network Monitor 2021-06-21 4.3 MEDIUM 4.3 MEDIUM
PRTG Network Monitor 20.1.55.1775 allows /editsettings CSRF for user account creation.
CVE-2021-27220 1 Paessler 1 Prtg Network Monitor 2021-04-06 5.0 MEDIUM 5.3 MEDIUM
An issue was discovered in PRTG Network Monitor before 21.1.66.1623. By invoking the screenshot functionality with prepared context paths, an attacker is able to verify the existence of certain files on the filesystem of the PRTG's Web server.
CVE-2020-14073 1 Paessler 1 Prtg Network Monitor 2020-12-02 3.5 LOW 5.4 MEDIUM
XSS exists in PRTG Network Monitor 20.1.56.1574 via crafted map properties. An attacker with Read/Write privileges can create a map, and then use the Map Designer Properties screen to insert JavaScript code. This can be exploited against any user with View Maps or Edit Maps access.
CVE-2020-11547 1 Paessler 1 Prtg Network Monitor 2020-04-07 5.0 MEDIUM 5.3 MEDIUM
PRTG Network Monitor before 20.1.57.1745 allows remote unauthenticated attackers to obtain information about probes running or the server itself (CPU usage, memory, Windows version, and internal statistics) via an HTTP request, as demonstrated by type=probes to login.htm or index.htm.
CVE-2019-9207 1 Paessler 1 Prtg Network Monitor 2020-01-03 4.3 MEDIUM 6.1 MEDIUM
PRTG Network Monitor v7.1.3.3378 allows XSS via the /search.htm searchtext parameter. NOTE: This product is discontinued.
CVE-2019-9206 1 Paessler 1 Prtg Network Monitor 2020-01-03 4.3 MEDIUM 6.1 MEDIUM
PRTG Network Monitor v7.1.3.3378 allows XSS via the /public/login.htm errormsg or loginurl parameter. NOTE: This product is discontinued.
CVE-2017-15917 1 Paessler 1 Prtg Network Monitor 2019-10-03 4.0 MEDIUM 6.5 MEDIUM
In Paessler PRTG Network Monitor 17.3.33.2830, it's possible to create a Map as a read-only user, by forging a request and sending it to the server.
CVE-2017-15360 1 Paessler 1 Prtg Network Monitor 2017-11-01 3.5 LOW 5.4 MEDIUM
PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all group names created, related to incorrect error handling for an HTML encoded script.
CVE-2017-15651 1 Paessler 1 Prtg Network Monitor 2017-10-31 6.5 MEDIUM 6.7 MEDIUM
PRTG Network Monitor 17.3.33.2830 allows remote authenticated administrators to execute arbitrary code by uploading a .exe file and then proceeding in spite of the error message.
CVE-2017-15008 1 Paessler 1 Prtg Network Monitor 2017-10-12 3.5 LOW 4.8 MEDIUM
PRTG Network Monitor version 17.3.33.2830 is vulnerable to stored Cross-Site Scripting on all sensor titles, related to incorrect error handling for a %00 in the SRC attribute of an IMG element.
CVE-2017-15009 1 Paessler 1 Prtg Network Monitor 2017-10-12 4.3 MEDIUM 6.1 MEDIUM
PRTG Network Monitor version 17.3.33.2830 is vulnerable to reflected Cross-Site Scripting on error.htm (the error page), via the errormsg parameter.
CVE-2017-12879 1 Paessler 1 Prtg Network Monitor 2017-09-12 3.5 LOW 5.4 MEDIUM
Cross-site scripting (XSS-STORED) vulnerability in the DEVICES OR SENSORS functionality in Paessler PRTG Network Monitor before 17.3.33.2654 allows authenticated remote attackers to inject arbitrary web script or HTML.
CVE-2017-9816 1 Paessler 1 Prtg Network Monitor 2017-08-24 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in Paessler PRTG Network Monitor before 17.2.32.2279 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2015-7743 1 Paessler 1 Prtg Network Monitor 2017-01-25 4.0 MEDIUM 6.5 MEDIUM
XML external entity vulnerability in PRTG Network Monitor before 16.2.23.3077/3078 allows remote authenticated users to read arbitrary files by creating a new HTTP XML/REST Value sensor that accesses a crafted XML file.