Vulnerabilities (CVE)

Filtered by vendor Cisco Subscribe
Filtered by product Sourcefire Defense Center
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-34763 1 Cisco 3 Firepower Management Center Virtual Appliance, Firepower Threat Defense, Sourcefire Defense Center 2021-10-28 3.5 LOW 4.8 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an attacker to execute a cross-site scripting (XSS) attack or an open redirect attack. For more information about these vulnerabilities, see the Details section of this advisory.
CVE-2021-34764 1 Cisco 3 Firepower Management Center Virtual Appliance, Firepower Threat Defense, Sourcefire Defense Center 2021-10-28 5.8 MEDIUM 6.1 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an attacker to execute a cross-site scripting (XSS) attack or an open redirect attack. For more information about these vulnerabilities, see the Details section of this advisory.
CVE-2021-34761 1 Cisco 3 Firepower Management Center Virtual Appliance, Firepower Threat Defense, Sourcefire Defense Center 2021-10-28 6.6 MEDIUM 6.0 MEDIUM
A vulnerability in Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to overwrite or append arbitrary data to system files using root-level privileges. The attacker must have administrative credentials on the device. This vulnerability is due to incomplete validation of user input for a specific CLI command. An attacker could exploit this vulnerability by authenticating to the device with administrative privileges and issuing a CLI command with crafted user parameters. A successful exploit could allow the attacker to overwrite or append arbitrary data to system files using root-level privileges.
CVE-2020-3320 1 Cisco 2 Firepower Management Center, Sourcefire Defense Center 2020-10-23 3.5 LOW 5.4 MEDIUM
A vulnerability in the web-based management interface of Cisco Firepower Management Center could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of an affected device. An attacker could exploit this vulnerability by first entering input within the web-based management interface and then persuading a user of the interface to view the crafted input within the interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.