Vulnerabilities (CVE)

Filtered by vendor Juniper Subscribe
Filtered by product Ex4600
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-22203 1 Juniper 11 Ex4600, Ex4650, Junos and 8 more 2022-07-27 N/A 6.5 MEDIUM
An Incorrect Comparison vulnerability in PFE of Juniper Networks Junos OS allows an adjacent unauthenticated attacker to cause a Denial of Service (DoS). On QFX5000 Series, and EX4600 and EX4650 platforms, the fxpc process will crash followed by the FPC reboot upon receipt of a specific hostbound packet. Continued receipt of these specific packets will create a sustained Denial of Service (DoS) condition. This issue only affects Juniper Networks Junos OS 19.4 version 19.4R3-S4.
CVE-2020-1618 1 Juniper 16 Ex2300, Ex2300-c, Ex3400 and 13 more 2021-11-22 6.9 MEDIUM 6.8 MEDIUM
On Juniper Networks EX and QFX Series, an authentication bypass vulnerability may allow a user connected to the console port to login as root without any password. This issue might only occur in certain scenarios: • At the first reboot after performing device factory reset using the command “request system zeroize”; or • A temporary moment during the first reboot after the software upgrade when the device configured in Virtual Chassis mode. This issue affects Juniper Networks Junos OS on EX and QFX Series: 14.1X53 versions prior to 14.1X53-D53; 15.1 versions prior to 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D593; 16.1 versions prior to 16.1R7-S4; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R2-S5, 17.3R3-S6; 17.4 versions prior to 17.4R2-S9, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R2; 18.3 versions prior to 18.3R1-S7, 18.3R2. This issue does not affect Juniper Networks Junos OS 12.3.
CVE-2020-1604 1 Juniper 7 Ex4300, Ex4600, Junos and 4 more 2021-11-18 5.0 MEDIUM 5.3 MEDIUM
On EX4300, EX4600, QFX3500, and QFX5100 Series, a vulnerability in the IP firewall filter component may cause the firewall filter evaluation of certain packets to fail. This issue only affects firewall filter evaluation of certain packets destined to the device Routing Engine (RE). This issue does not affect the Layer 2 firewall filter evaluation nor does it affect the Layer 3 firewall filter evaluation destined to connected hosts. This issue may occur when evaluating both IPv4 or IPv6 packets. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D12 on QFX5100 Series and EX4600 Series; 14.1X53 versions prior to 14.1X53-D52 on QFX3500 Series; 14.1X53 versions prior to 14.1X53-D48 on EX4300 Series; 15.1 versions prior to 15.1R7-S3 on EX4300 Series; 16.1 versions prior to 16.1R7 on EX4300 Series; 17.1 versions prior to 17.1R3 on EX4300 Series; 17.2 versions prior to 17.2R3 on EX4300 Series; 17.3 versions prior to 17.3R2-S5, 17.3R3 on EX4300 Series; 17.4 versions prior to 17.4R2 on EX4300 Series; 18.1 versions prior to 18.1R3 on EX4300 Series; 18.2 versions prior to 18.2R2 on EX4300 Series.
CVE-2019-0005 1 Juniper 14 Ex2300, Ex2300-c, Ex3400 and 11 more 2021-11-09 5.0 MEDIUM 5.3 MEDIUM
On EX2300, EX3400, EX4600, QFX3K and QFX5K series, firewall filter configuration cannot perform packet matching on any IPv6 extension headers. This issue may allow IPv6 packets that should have been blocked to be forwarded. IPv4 packet filtering is unaffected by this vulnerability. Affected releases are Juniper Networks Junos OS on EX and QFX series;: 14.1X53 versions prior to 14.1X53-D47; 15.1 versions prior to 15.1R7; 15.1X53 versions prior to 15.1X53-D234 on QFX5200/QFX5110 series; 15.1X53 versions prior to 15.1X53-D591 on EX2300/EX3400 series; 16.1 versions prior to 16.1R7; 17.1 versions prior to 17.1R2-S10, 17.1R3; 17.2 versions prior to 17.2R3; 17.3 versions prior to 17.3R3; 17.4 versions prior to 17.4R2; 18.1 versions prior to 18.1R2.
CVE-2021-31370 1 Juniper 15 Ex4600, Ex4600-vc, Ex4650 and 12 more 2021-10-25 3.3 LOW 6.5 MEDIUM
An Incomplete List of Disallowed Inputs vulnerability in Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on QFX5000 Series and EX4600 Series allows an adjacent unauthenticated attacker which sends a high rate of specific multicast traffic to cause control traffic received from the network to be dropped. This will impact control protocols (including but not limited to routing-protocols) and lead to a Denial of Service (DoS). Continued receipt of this specific multicast traffic will create a sustained Denial of Service (DoS) condition. This issue affects Juniper Networks Junos OS on QFX5000 and EX4600 Series: All versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R3-S3; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2-S2, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2.
CVE-2021-0294 1 Juniper 8 Ex4600, Ex4650, Junos and 5 more 2021-07-28 5.0 MEDIUM 5.3 MEDIUM
A vulnerability in Juniper Networks Junos OS, which only affects the release 18.4R2-S5, where a function is inconsistently implemented on Juniper Networks Junos QFX5000 Series and EX4600 Series, and if "storm-control enhanced" is configured, can lead to the enhanced storm control filter group not be installed. It will cause storm control not to work hence allowing an attacker to cause high CPU usage or packet loss issues by sending a large amount of broadcast or unknown unicast packets arriving the device. This issue affects Juniper Networks QFX5100, QFX5110, QFX5120, QFX5200, QFX5210, EX4600, and EX4650, and QFX5100 with QFX 5e Series image installed. QFX5130 and QFX5220 are not affected from this issue. This issue affects Juniper Networks Junos OS 18.4R2-S5 on QFX5000 Series and EX4600 Series. No other product or platform is affected by this vulnerability.
CVE-2021-0289 1 Juniper 229 Acx1000, Acx1100, Acx2000 and 226 more 2021-07-28 2.9 LOW 5.3 MEDIUM
When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved.
CVE-2021-0237 1 Juniper 11 Ex4300-mp, Ex4600, Ex4650 and 8 more 2021-07-23 3.3 LOW 6.5 MEDIUM
On Juniper Networks EX4300-MP Series, EX4600 Series, EX4650 Series, QFX5K Series deployed as a Virtual Chassis with a specific Layer 2 circuit configuration, Packet Forwarding Engine manager (FXPC) process may crash and restart upon receipt of specific layer 2 frames. Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on EX4300-MP Series, EX4600 Series, EX4650 Series, QFX5K Series 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S4, 17.4R3-S5; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S7, 18.4R3-S6; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S1; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R2-S4, 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2, 20.2R3; 20.3 versions prior to 20.3R1-S2, 20.3R2;
CVE-2018-0034 1 Juniper 56 Ex2200, Ex2200-c, Ex2200-vc and 53 more 2021-06-21 4.3 MEDIUM 5.9 MEDIUM
A Denial of Service vulnerability exists in the Juniper Networks Junos OS JDHCPD daemon which allows an attacker to core the JDHCPD daemon by sending a crafted IPv6 packet to the system. This issue is limited to systems which receives IPv6 DHCP packets on a system configured for DHCP processing using the JDHCPD daemon. This issue does not affect IPv4 DHCP packet processing. Affected releases are Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S10 on EX Series; 12.3X48 versions prior to 12.3X48-D70 on SRX Series; 14.1X53 versions prior to 14.1X53-D47 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 14.1X53 versions prior to 14.1X53-D130 on QFabric; 15.1 versions prior to 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D67 on QFX10000 Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5110, QFX5200; 15.1X53 versions prior to 15.1X53-D471 on NFX 150, NFX 250; 16.1 versions prior to 16.1R3-S9, 16.1R4-S8, 16.1R5-S4, 16.1R6-S3, 16.1R7; 16.2 versions prior to 16.2R2-S5, 16.2R3; 17.1 versions prior to 17.1R1-S7, 17.1R2-S7, 17.1R3; 17.2 versions prior to 17.2R1-S6, 17.2R2-S4, 17.2R3; 17.3 versions prior to 17.3R1-S4, 17.3R2-S2, 17.3R3; 17.4 versions prior to 17.4R1-S3, 17.4R2.
CVE-2018-0008 1 Juniper 40 Ex2200, Ex2300, Ex3300 and 37 more 2021-06-16 7.2 HIGH 6.2 MEDIUM
An unauthenticated root login may allow upon reboot when a commit script is used. A commit script allows a device administrator to execute certain instructions during commit, which is configured under the [system scripts commit] stanza. Certain commit scripts that work without a problem during normal commit may cause unexpected behavior upon reboot which can leave the system in a state where root CLI login is allowed without a password due to the system reverting to a "safe mode" authentication state. Lastly, only logging in physically to the console port as root, with no password, will work. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71 on SRX; 12.3X48 versions prior to 12.3X48-D55 on SRX; 14.1 versions prior to 14.1R9; 14.1X53 versions prior to 14.1X53-D40 on QFX, EX; 14.2 versions prior to 14.2R7-S9, 14.2R8; 15.1 versions prior to 15.1F5-S7, 15.1F6-S8, 15.1R5-S6, 15.1R6; 15.1X49 versions prior to 15.1X49-D110 on SRX; 15.1X53 versions prior to 15.1X53-D232 on QFX5200/5110; 15.1X53 versions prior to 15.1X53-D49, 15.1X53-D470 on NFX; 15.1X53 versions prior to 15.1X53-D65 on QFX10K; 16.1 versions prior to 16.1R2. No other Juniper Networks products or platforms are affected by this issue.
CVE-2019-0069 1 Juniper 12 Acx5000, Ex4600, Junos and 9 more 2021-02-05 2.1 LOW 5.5 MEDIUM
On EX4600, QFX5100 Series, NFX Series, QFX10K Series, QFX5110, QFX5200 Series, QFX5110, QFX5200, QFX10K Series, vSRX, SRX1500, SRX4000 Series, vSRX, SRX1500, SRX4000, QFX5110, QFX5200, QFX10K Series, when the user uses console management port to authenticate, the credentials used during device authentication are written to a log file in clear text. This issue does not affect users that are logging-in using telnet, SSH or J-web to the management IP. This issue affects ACX, NFX, SRX, EX and QFX platforms with the Linux Host OS architecture, it does not affect other SRX and EX platforms that do not use the Linux Host OS architecture. This issue affects Juniper Networks Junos OS: 15.1X49 versions prior to 15.1X49-D110 on vSRX, SRX1500, SRX4000 Series; 15.1X53 versions prior to 15.1X53-D234 on QFX5110, QFX5200 Series; 15.1X53 versions prior to 15.1X53-D68 on QFX10K Series; 17.1 versions prior to 17.1R2-S8, 17.1R3, on QFX5110, QFX5200, QFX10K Series; 17.2 versions prior to 17.2R1-S7, 17.2R2-S6, 17.2R3 on QFX5110, QFX5200, QFX10K Series; 17.3 versions prior to 17.3R2 on vSRX, SRX1500, SRX4000, QFX5110, QFX5200, QFX10K Series; 14.1X53 versions prior to 14.1X53-D47 on ACX5000, EX4600, QFX5100 Series; 15.1 versions prior to 15.1R7 on ACX5000, EX4600, QFX5100 Series; 16.1R7 versions prior to 16.1R7 on ACX5000, EX4600, QFX5100 Series; 17.1 versions prior to 17.1R2-S10, 17.1R3 on ACX5000, EX4600, QFX5100 Series; 17.2 versions prior to 17.2R3 on ACX5000, EX4600, QFX5100 Series; 17.3 versions prior to 17.3R3 on ACX5000, EX4600, QFX5100 Series; 17.4 versions prior to 17.4R2 on ACX5000, EX4600, QFX5100 Series; 18.1 versions prior to 18.1R2 on ACX5000, EX4600, QFX5100 Series; 15.1X53 versions prior to 15.1X53-D496 on NFX Series, 17.2 versions prior to 17.2R3-S1 on NFX Series; 17.3 versions prior to 17.3R3-S4 on NFX Series; 17.4 versions prior to 17.4R2-S4, 17.4R3 on NFX Series, 18.1 versions prior to 18.1R3-S4 on NFX Series; 18.2 versions prior to 18.2R2-S3, 18.2R3 on NFX Series; 18.3 versions prior to 18.3R1-S3, 18.3R2 on NFX Series; 18.4 versions prior to 18.4R1-S1, 18.4R2 on NFX Series.
CVE-2020-1661 1 Juniper 32 Ex2300, Ex2300-c, Ex3400 and 29 more 2020-10-26 4.3 MEDIUM 5.3 MEDIUM
On Juniper Networks Junos OS devices configured as a DHCP forwarder, the Juniper Networks Dynamic Host Configuration Protocol Daemon (jdhcp) process might crash when receiving a malformed DHCP packet. This issue only affects devices configured as DHCP forwarder with forward-only option, that forward specified DHCP client packets, without creating a new subscriber session. The jdhcpd daemon automatically restarts without intervention, but continuous receipt of the malformed DHCP packet will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue can be triggered only by DHCPv4, it cannot be triggered by DHCPv6. This issue affects Juniper Networks Junos OS: 12.3 versions prior to 12.3R12-S16; 12.3X48 versions prior to 12.3X48-D105 on SRX Series; 14.1X53 versions prior to 14.1X53-D60 on EX and QFX Series; 15.1 versions prior to 15.1R7-S7; 15.1X49 versions prior to 15.1X49-D221, 15.1X49-D230 on SRX Series; 15.1X53 versions prior to 15.1X53-D593 on EX2300/EX3400; 16.1 versions prior to 16.1R7-S5.
CVE-2019-0003 1 Juniper 35 Ex2200\/vc, Ex2300, Ex3200 and 32 more 2020-09-29 4.3 MEDIUM 5.9 MEDIUM
When a specific BGP flowspec configuration is enabled and upon receipt of a specific matching BGP packet meeting a specific term in the flowspec configuration, a reachable assertion failure occurs, causing the routing protocol daemon (rpd) process to crash with a core file being generated. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D77 on SRX Series; 12.3 versions prior to 12.3R12-S10; 12.3X48 versions prior to 12.3X48-D70 on SRX Series; 14.1X53 versions prior to 14.1X53-D47 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 15.1 versions prior to 15.1R3; 15.1F versions prior to 15.1F3; 15.1X49 versions prior to 15.1X49-D140 on SRX Series; 15.1X53 versions prior to 15.1X53-D59 on EX2300/EX3400.
CVE-2020-1607 1 Juniper 44 Ex2300, Ex2300-c, Ex3400 and 41 more 2020-01-24 4.3 MEDIUM 6.1 MEDIUM
Insufficient Cross-Site Scripting (XSS) protection in J-Web may potentially allow a remote attacker to inject web script or HTML, hijack the target user's J-Web session and perform administrative actions on the Junos device as the targeted user. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D86, 12.3X48-D90 on SRX Series; 14.1X53 versions prior to 14.1X53-D51 on EX and QFX Series; 15.1F6 versions prior to 15.1F6-S13; 15.1 versions prior to 15.1R7-S5; 15.1X49 versions prior to 15.1X49-D181, 15.1X49-D190 on SRX Series; 15.1X53 versions prior to 15.1X53-D238 on QFX5200/QFX5110 Series; 15.1X53 versions prior to 15.1X53-D592 on EX2300/EX3400 Series; 16.1 versions prior to 16.1R4-S13, 16.1R7-S5; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S2; 17.3 versions prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3; 18.3 versions prior to 18.3R1-S6, 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R1-S5, 18.4R2; 19.1 versions prior to 19.1R1-S2, 19.1R2.
CVE-2018-0060 1 Juniper 15 Ex2300, Ex3200, Ex3400 and 12 more 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
An improper input validation weakness in the device control daemon process (dcd) of Juniper Networks Junos OS allows an attacker to cause a Denial of Service to the dcd process and interfaces and connected clients when the Junos device is requesting an IP address for itself. Junos devices are not vulnerable to this issue when not configured to use DHCP. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D40 on SRX Series; 12.3X48 versions prior to 12.3X48-D20 on SRX Series; 14.1X53 versions prior to 14.1X53-D40 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 15.1X49 versions prior to 15.1X49-D20 on SRX Series; 15.1X53 versions prior to 15.1X53-D68 on QFX10000 Series; 15.1X53 versions prior to 15.1X53-D235 on QFX5200/QFX5110; 15.1X53 versions prior to 15.1X53-D495 on NFX150, NFX250; 15.1X53 versions prior to 15.1X53-D590 on EX2300/EX3400; 15.1 versions prior to 15.1R7-S2.
CVE-2018-0054 1 Juniper 8 Ex3400, Ex4600, Junos and 5 more 2019-10-09 3.3 LOW 6.5 MEDIUM
On QFX5000 Series and EX4600 switches, a high rate of Ethernet pause frames or an ARP packet storm received on the management interface (fxp0) can cause egress interface congestion, resulting in routing protocol packet drops, such as BGP, leading to peering flaps. The following log message may also be displayed: fpc0 dcbcm_check_stuck_buffers: Buffers are stuck on queue 7 of port 45 This issue only affects the QFX5000 Series products (QFX5100, QFX5110, QFX5200, QFX5210) and the EX4600 switch. No other platforms are affected by this issue. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D47 on QFX5000 Series and EX4600; 15.1 versions prior to 15.1R7, 15.1R8 on QFX5000 Series and EX4600; 15.1X53 versions prior to 15.1X53-D233 on QFX5000 Series and EX4600; 16.1 versions prior to 16.1R7 on QFX5000 Series and EX4600; 16.2 versions prior to 16.2R3 on QFX5000 Series and EX4600; 17.1 versions prior to 17.1R2-S9, 17.1R3 on QFX5000 Series and EX4600; 17.2 versions prior to 17.2R2-S6, 17.2R3 on QFX5000 Series and EX4600; 17.2X75 versions prior to 17.2X75-D42 on QFX5000 Series and EX4600; 17.3 versions prior to 17.3R3 on QFX5000 Series and EX4600; 17.4 versions prior to 17.4R2 on QFX5000 Series and EX4600; 18.1 versions prior to 18.1R2 on QFX5000 Series and EX4600.
CVE-2018-0019 1 Juniper 12 Ex2300, Ex3400, Ex4300 and 9 more 2019-10-09 4.3 MEDIUM 5.9 MEDIUM
A vulnerability in Junos OS SNMP MIB-II subagent daemon (mib2d) may allow a remote network based attacker to cause the mib2d process to crash resulting in a denial of service condition (DoS) for the SNMP subsystem. While a mib2d process crash can disrupt the network monitoring via SNMP, it does not impact routing, switching or firewall functionalities. SNMP is disabled by default on devices running Junos OS. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D76; 12.3 versions prior to 12.3R12-S7, 12.3R13; 12.3X48 versions prior to 12.3X48-D65; 14.1 versions prior to 14.1R9; 14.1X53 versions prior to 14.1X53-D130; 15.1 versions prior to 15.1F2-S20, 15.1F6-S10, 15.1R7; 15.1X49 versions prior to 15.1X49-D130; 15.1X53 versions prior to 15.1X53-D233, 15.1X53-D471, 15.1X53-D472, 15.1X53-D58, 15.1X53-D66; 16.1 versions prior to 16.1R5-S3, 16.1R7; 16.1X65 versions prior to 16.1X65-D47; 16.1X70 versions prior to 16.1X70-D10; 16.2 versions prior to 16.2R1-S6, 16.2R2-S5, 16.2R3; 17.1 versions prior to 17.1R2-S6, 17.1R3;