| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-7546 | 1 Schneider-electric | 5 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Power Manager and 2 more | 2020-12-04 | 3.5 LOW | 5.4 MEDIUM |
| A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage. | |||||
| CVE-2018-7824 | 2 Microsoft, Schneider-electric | 3 Windows, Driver Suite, Modbus Serial Driver | 2020-09-29 | 6.8 MEDIUM | 4.9 MEDIUM |
| An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files. | |||||
| CVE-2018-7788 | 1 Schneider-electric | 2 Modicon Quantum, Modicon Quantum Firmware | 2020-09-29 | 4.0 MEDIUM | 6.5 MEDIUM |
| A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection. | |||||
| CVE-2020-7529 | 1 Schneider-electric | 1 Scadapack 7x Remote Connect | 2020-09-21 | 4.3 MEDIUM | 5.5 MEDIUM |
| A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file. | |||||
| CVE-2018-7803 | 1 Schneider-electric | 1 Triconex Tristation Emulator | 2020-08-24 | 4.3 MEDIUM | 5.9 MEDIUM |
| A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant. | |||||
| CVE-2018-7816 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2020-08-24 | 5.5 MEDIUM | 6.5 MEDIUM |
| A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file. | |||||
| CVE-2020-7520 | 1 Schneider-electric | 1 Software Update Utility | 2020-07-28 | 4.0 MEDIUM | 4.7 MEDIUM |
| A CWE-601: URL Redirection to Untrusted Site ('Open Redirect') vulnerability exists in Schneider Electric Software Update (SESU), V2.4.0 and prior, which could cause execution of malicious code on the victim's machine. In order to exploit this vulnerability, an attacker requires privileged access on the engineering workstation to modify a Windows registry key which would divert all traffic updates to go through a server in the attacker's possession. A man-in-the-middle attack is then used to complete the exploit. | |||||
| CVE-2020-7517 | 1 Schneider-electric | 1 Easergy Builder | 2020-07-27 | 2.1 LOW | 5.5 MEDIUM |
| A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to read user credentials. | |||||
| CVE-2012-0930 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2020-07-23 | 4.3 MEDIUM | 6.1 MEDIUM |
| Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
| CVE-2020-7492 | 1 Schneider-electric | 1 Gp-pro Ex Firmware | 2020-06-24 | 4.3 MEDIUM | 6.5 MEDIUM |
| A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded. | |||||
| CVE-2020-7495 | 1 Schneider-electric | 1 Ecostruxure Operator Terminal Expert | 2020-06-19 | 4.3 MEDIUM | 5.5 MEDIUM |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access outside of expected path folder when opening the project file. | |||||
| CVE-2020-7504 | 1 Schneider-electric | 2 Easergy T300, Easergy T300 Firmware | 2020-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| A CWE-20: Improper Input Validation vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to disable the webserver service on the device when specially crafted network packets are sent. | |||||
| CVE-2020-7481 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2020-03-24 | 4.3 MEDIUM | 6.1 MEDIUM |
| A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server. | |||||
| CVE-2020-7482 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2020-03-24 | 4.3 MEDIUM | 6.1 MEDIUM |
| A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server. | |||||
| CVE-2019-6833 | 1 Schneider-electric | 49 Hmig2u, Hmig3u, Hmig3ufc and 46 more | 2020-02-10 | 4.3 MEDIUM | 6.5 MEDIUM |
| A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel. | |||||
| CVE-2018-7827 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2020-02-10 | 3.5 LOW | 5.4 MEDIUM |
| A Cross-Site Scripting (XSS) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which a remote attacker can execute arbitrary HTML and script code in a user’s browser session. | |||||
| CVE-2019-6853 | 1 Schneider-electric | 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more | 2019-12-03 | 4.3 MEDIUM | 6.1 MEDIUM |
| A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server. | |||||
| CVE-2019-6830 | 1 Schneider-electric | 2 Modicon M580, Modicon M580 Firmware | 2019-10-09 | 7.1 HIGH | 5.9 MEDIUM |
| A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller. | |||||
| CVE-2019-6835 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page. | |||||
| CVE-2018-7522 | 1 Schneider-electric | 2 Triconex Tricon Mp 3008, Triconex Tricon Mp 3008 Firmware | 2019-10-09 | 7.2 HIGH | 6.7 MEDIUM |
| In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states. | |||||
| CVE-2018-7834 | 1 Schneider-electric | 2 Tsxetg100, Tsxetg100 Firmware | 2019-10-09 | 4.3 MEDIUM | 6.1 MEDIUM |
| A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user. | |||||
| CVE-2017-9637 | 1 Schneider-electric | 1 Ampla Manufacturing Execution System | 2019-10-09 | 1.9 LOW | 4.1 MEDIUM |
| Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. | |||||
| CVE-2017-6032 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2019-10-09 | 5.0 MEDIUM | 5.3 MEDIUM |
| A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. | |||||
| CVE-2015-6462 | 1 Schneider-electric | 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more | 2019-10-09 | 3.5 LOW | 5.4 MEDIUM |
| Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser. | |||||
| CVE-2015-6461 | 1 Schneider-electric | 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more | 2019-10-09 | 5.5 MEDIUM | 5.4 MEDIUM |
| Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. | |||||
| CVE-2017-7970 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2019-10-03 | 3.3 LOW | 6.5 MEDIUM |
| A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components. | |||||
| CVE-2017-7972 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2019-10-03 | 5.2 MEDIUM | 5.5 MEDIUM |
| A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes. | |||||
| CVE-2017-9969 | 1 Schneider-electric | 1 Igss Mobile | 2019-10-03 | 2.1 LOW | 6.7 MEDIUM |
| An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information. | |||||
| CVE-2018-7770 | 1 Schneider-electric | 1 U.motion | 2019-10-03 | 4.3 MEDIUM | 6.5 MEDIUM |
| The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address. | |||||
| CVE-2017-8371 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2019-10-03 | 4.0 MEDIUM | 6.8 MEDIUM |
| Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors. | |||||
| CVE-2017-9959 | 1 Schneider-electric | 1 U.motion Builder | 2019-10-03 | 4.9 MEDIUM | 5.5 MEDIUM |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition. | |||||
| CVE-2018-7839 | 1 Schneider-electric | 1 Iiot Monitor | 2019-06-07 | 2.1 LOW | 5.5 MEDIUM |
| A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure. | |||||
| CVE-2018-7797 | 1 Schneider-electric | 3 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Ecostruxure Power Scada Operation | 2019-02-11 | 5.8 MEDIUM | 6.1 MEDIUM |
| A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site. | |||||
| CVE-2018-7796 | 1 Schneider-electric | 1 Powersuite 2 | 2019-01-11 | 6.8 MEDIUM | 6.3 MEDIUM |
| A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability. | |||||
| CVE-2018-7810 | 1 Schneider-electric | 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more | 2018-12-28 | 4.3 MEDIUM | 6.1 MEDIUM |
| An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially impacting the machine the browser is running on. | |||||
| CVE-2018-7804 | 1 Schneider-electric | 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more | 2018-12-28 | 5.8 MEDIUM | 6.1 MEDIUM |
| A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing. | |||||
| CVE-2018-7795 | 1 Schneider-electric | 2 Powerlogic Pm5560, Powerlogic Pm5560 Firmware | 2018-11-07 | 4.3 MEDIUM | 6.1 MEDIUM |
| A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code. | |||||
| CVE-2015-6485 | 1 Schneider-electric | 8 Sage 1410, Sage 1430, Sage 1450 and 5 more | 2018-10-30 | 5.0 MEDIUM | 5.3 MEDIUM |
| Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet. | |||||
| CVE-2018-7763 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-28 | 4.3 MEDIUM | 4.3 MEDIUM |
| The vulnerability exists within css.inc.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The 'css' parameter contains a directory traversal vulnerability. | |||||
| CVE-2018-7787 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-28 | 5.0 MEDIUM | 5.3 MEDIUM |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request. | |||||
| CVE-2018-7786 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-28 | 4.3 MEDIUM | 6.1 MEDIUM |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts. | |||||
| CVE-2018-7776 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-28 | 4.3 MEDIUM | 4.3 MEDIUM |
| The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data. | |||||
| CVE-2018-7764 | 1 Schneider-electric | 1 U.motion Builder | 2018-08-28 | 4.3 MEDIUM | 4.3 MEDIUM |
| The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4. There is a directory traversal vulnerability in the processing of the 's' parameter of the applet. | |||||
| CVE-2018-7758 | 1 Schneider-electric | 46 Micom P141, Micom P141 Firmware, Micom P142 and 43 more | 2018-05-29 | 3.3 LOW | 6.5 MEDIUM |
| A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number. | |||||
| CVE-2018-7244 | 1 Schneider-electric | 11 66074 Mge Network Management Card Transverse, Mge Comet Ups, Mge Eps 6000 and 8 more | 2018-05-23 | 5.0 MEDIUM | 5.3 MEDIUM |
| An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained. | |||||
| CVE-2017-9968 | 1 Schneider-electric | 1 Igss Mobile | 2018-03-09 | 4.3 MEDIUM | 5.9 MEDIUM |
| A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack. | |||||
| CVE-2017-9964 | 1 Schneider-electric | 1 Pelco Videoxpert | 2018-02-13 | 5.8 MEDIUM | 6.9 MEDIUM |
| A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack. | |||||
| CVE-2017-9965 | 1 Schneider-electric | 1 Pelco Videoxpert | 2018-02-13 | 5.0 MEDIUM | 5.8 MEDIUM |
| An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files. | |||||
| CVE-2017-7971 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2017-09-29 | 4.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate. | |||||
| CVE-2017-9960 | 1 Schneider-electric | 1 U.motion Builder | 2017-09-27 | 5.0 MEDIUM | 5.3 MEDIUM |
| An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system response to error provides more information than should be available to an unauthenticated user. | |||||