Search
Total
4 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2020-27748 | 1 Freedesktop | 1 Xdg-utils | 2021-06-11 | 4.3 MEDIUM | 6.5 MEDIUM |
| A flaw was found in the xdg-email component of xdg-utils-1.1.0-rc1 and newer. When handling mailto: URIs, xdg-email allows attachments to be discreetly added via the URI when being passed to Thunderbird. An attacker could potentially send a victim a URI that automatically attaches a sensitive file to a new email. If a victim user does not notice that an attachment was added and sends the email, this could result in sensitive information disclosure. It has been confirmed that the code behind this issue is in xdg-email and not in Thunderbird. | |||||
| CVE-2021-1128 | 1 Cisco | 1 Ios Xr | 2021-02-08 | 2.1 LOW | 5.5 MEDIUM |
| A vulnerability in the CLI parser of Cisco IOS XR Software could allow an authenticated, local attacker to view more information than their privileges allow. The vulnerability is due to insufficient application of restrictions during the execution of a specific command. An attacker could exploit this vulnerability by using a specific command at the command line. A successful exploit could allow the attacker to obtain sensitive information within the configuration that otherwise might not have been accessible beyond the privileges of the invoking user. | |||||
| CVE-2021-1129 | 1 Cisco | 3 Content Security Management Appliance, Email Security Appliance, Web Security Appliance | 2021-01-27 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability in the authentication for the general purpose APIs implementation of Cisco Email Security Appliance (ESA), Cisco Content Security Management Appliance (SMA), and Cisco Web Security Appliance (WSA) could allow an unauthenticated, remote attacker to access general system information and certain configuration information from an affected device. The vulnerability exists because a secure authentication token is not required when authenticating to the general purpose API. An attacker could exploit this vulnerability by sending a crafted request for information to the general purpose API on an affected device. A successful exploit could allow the attacker to obtain system and configuration information from the affected device, resulting in an unauthorized information disclosure. | |||||
| CVE-2020-14514 | 1 Nmfc | 1 Power Line Communications | 2020-09-11 | 3.3 LOW | 4.3 MEDIUM |
| All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements. | |||||