Vulnerabilities (CVE)

Filtered by vendor Secomea Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-25785 1 Secomea 18 Sitemanager 1129, Sitemanager 1129 Firmware, Sitemanager 1139 and 15 more 2022-05-11 6.5 MEDIUM 7.2 HIGH
Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7.
CVE-2022-25778 1 Secomea 8 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 5 more 2022-05-11 6.8 MEDIUM 8.8 HIGH
Cross-Site Request Forgery (CSRF) vulnerability in Web UI of Secomea GateManager allows phishing attacker to issue get request in logged in user session.
CVE-2021-32010 1 Secomea 27 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 24 more 2022-05-11 6.8 MEDIUM 8.1 HIGH
Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.
CVE-2020-29032 1 Secomea 2 Gatemanager 8250, Gatemanager 8250 Firmware 2021-03-12 6.5 MEDIUM 7.2 HIGH
Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022
CVE-2020-29020 1 Secomea 2 Sitemanager, Sitemanager Firmware 2021-03-12 6.5 MEDIUM 7.2 HIGH
Improper Access Control vulnerability in web service of Secomea SiteManager allows remote attacker to access the web UI from the internet using the configured credentials. This issue affects: Secomea SiteManager All versions prior to 9.4.620527004 on Hardware.
CVE-2020-29030 1 Secomea 1 Gatemanager Firmware 2021-03-12 6.8 MEDIUM 8.8 HIGH
Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4.
CVE-2020-29031 1 Secomea 8 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 5 more 2021-02-26 5.5 MEDIUM 8.1 HIGH
An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c
CVE-2020-14512 1 Secomea 2 Gatemanager 8250, Gatemanager 8250 Firmware 2020-08-27 5.0 MEDIUM 7.5 HIGH
GateManager versions prior to 9.2c, The affected product uses a weak hash type, which may allow an attacker to view user passwords.