Filtered by vendor Iconics
Subscribe
Search
Total
10 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-6061 | 1 Iconics | 1 Iconics Suite | 2023-12-12 | N/A | 7.8 HIGH |
| Multiple components of Iconics SCADA Suite are prone to a Phantom DLL loading vulnerability. This issue arises from the applications improperly searching for and loading dynamic link libraries, potentially allowing an attacker to execute malicious code via a DLL with a matching name in an accessible search path. The affected components are: * MMXFax.exe * winfax.dll * MelSim2ComProc.exe * Sim2ComProc.dll * MMXCall_in.exe * libdxxmt.dll * libsrlmt.dll | |||||
| CVE-2022-33316 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2022-07-27 | N/A | 7.8 HIGH |
| Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | |||||
| CVE-2022-33315 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2022-07-27 | N/A | 7.8 HIGH |
| Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | |||||
| CVE-2022-33317 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2022-07-27 | N/A | 7.8 HIGH |
| Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes. | |||||
| CVE-2022-29834 | 1 Iconics | 1 Genesis64 | 2022-07-27 | N/A | 7.5 HIGH |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS GENESIS64 versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 mobile monitoring application and accessing the monitoring screen. | |||||
| CVE-2022-33320 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2022-07-27 | N/A | 7.8 HIGH |
| Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes. | |||||
| CVE-2021-27041 | 3 Autodesk, Iconics, Mitsubishielectric | 13 Advance Steel, Autocad, Autocad Architecture and 10 more | 2022-05-13 | 6.8 MEDIUM | 7.8 HIGH |
| A maliciously crafted DWG file can be used to write beyond the allocated buffer while parsing DWG files. This vulnerability can be exploited to execute arbitrary code | |||||
| CVE-2020-12009 | 2 Iconics, Mitsubishielectric | 11 Bizviz, Energy Analytix, Facility Analytix and 8 more | 2020-07-29 | 5.0 MEDIUM | 7.5 HIGH |
| A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior. | |||||
| CVE-2020-12015 | 2 Iconics, Mitsubishielectric | 11 Bizviz, Energy Analytix, Facility Analytix and 8 more | 2020-07-22 | 5.0 MEDIUM | 7.5 HIGH |
| A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior. | |||||
| CVE-2016-2289 | 1 Iconics | 1 Webhmi | 2016-04-04 | 5.0 MEDIUM | 7.5 HIGH |
| Directory traversal vulnerability in ICONICS WebHMI 9 and earlier allows remote attackers to read configuration files, and consequently discover password hashes, via unspecified vectors. | |||||