CVE-2021-43283 1 Govicture 2 Wr1200, Wr1200 Firmware 2021-12-03 9.0 HIGH 8.8 HIGH
An issue was discovered on Victure WR1200 devices through 1.0.3. A command injection vulnerability was found within the web interface of the device, allowing an attacker with valid credentials to inject arbitrary shell commands to be executed by the device with root privileges. This occurs in the ping and traceroute features. An attacker would thus be able to use this vulnerability to open a reverse shell on the device with root privileges.
CVE-2021-43284 1 Govicture 2 Wr1200, Wr1200 Firmware 2021-12-03 7.2 HIGH 7.8 HIGH
An issue was discovered on Victure WR1200 devices through 1.0.3. The root SSH password never gets updated from its default value of admin. This enables an attacker to gain control of the device through SSH (regardless of whether the admin password was changed on the web interface).