Vulnerabilities (CVE)

Filtered by vendor Flexense Subscribe
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-15950 1 Flexense 1 Syncbreeze 2021-03-29 6.8 MEDIUM 7.8 HIGH
Flexense SyncBreeze Enterprise version 10.1.16 is vulnerable to a buffer overflow that can be exploited for arbitrary code execution. The flaw is triggered by providing a long input into the "Destination directory" field, either within an XML document or through use of passive mode.
CVE-2018-5261 1 Flexense 1 Diskboss 2019-10-03 4.3 MEDIUM 8.1 HIGH
An issue was discovered in Flexense DiskBoss 8.8.16 and earlier. Due to the usage of plaintext information from the handshake as input for the encryption key used for the encryption of the rest of the session, the server and client disclose sensitive information, such as the authentication credentials, to any man-in-the-middle (MiTM) listener.
CVE-2017-15667 1 Flexense 1 Sysgauge 2018-04-13 5.0 MEDIUM 7.5 HIGH
In Flexense SysGauge Server 3.6.18, the Control Protocol suffers from a denial of service. The attack vector is a crafted SERVER_GET_INFO packet sent to control port 9221.
CVE-2018-8065 1 Flexense 1 Syncbreeze 2018-04-11 5.0 MEDIUM 7.5 HIGH
An issue was discovered in the web server in Flexense SyncBreeze Enterprise 10.6.24. There is a user mode write access violation on the syncbrs.exe memory region that can be triggered by rapidly sending a variety of HTTP requests with long HTTP header values or long URIs.
CVE-2017-7310 1 Flexense 3 Diskboss, Disksorter, Syncbreeze 2018-03-08 6.8 MEDIUM 7.8 HIGH
A buffer overflow vulnerability in Import Command in SyncBreeze before 10.6, DiskSorter before 10.6, DiskBoss before 8.9, DiskPulse before 10.6, DiskSavvy before 10.6, DupScout before 10.6, and VX Search before 10.6 allows attackers to execute arbitrary code via a crafted XML file containing a long name attribute of a classify element.
CVE-2017-17996 1 Flexense 1 Syncbreeze 2018-02-27 9.0 HIGH 8.8 HIGH
A buffer overflow vulnerability in "Add command" functionality exists in Flexense SyncBreeze Enterprise <= 10.3.14. The vulnerability can be triggered by an authenticated attacker who submits more than 5000 characters as the command name. It will cause termination of the SyncBreeze Enterprise server and possibly remote command execution with SYSTEM privilege.
CVE-2018-5359 1 Flexense 1 Sysgauge 2018-02-09 9.3 HIGH 8.1 HIGH
The server in Flexense SysGauge 3.6.18 operating on port 9221 can be exploited remotely with the attacker gaining system-level access because of a Buffer Overflow.
CVE-2017-15662 1 Flexense 1 Vx Search 2018-02-01 5.0 MEDIUM 7.5 HIGH
In Flexense VX Search Enterprise v10.1.12, the Control Protocol suffers from a denial of service vulnerability. The attack vector is a crafted SERVER_GET_INFO packet sent to control port 9123.
CVE-2017-15663 1 Flexense 1 Disk Pulse 2018-02-01 5.0 MEDIUM 7.5 HIGH
In Flexense Disk Pulse Enterprise v10.1.18, the Control Protocol suffers from a denial of service vulnerability. The attack vector is a crafted SERVER_GET_INFO packet sent to control port 9120.
CVE-2017-15664 1 Flexense 1 Syncbreeze 2018-02-01 5.0 MEDIUM 7.5 HIGH
In Flexense Sync Breeze Enterprise v10.1.16, the Control Protocol suffers from a denial of service vulnerability. The attack vector is a crafted SERVER_GET_INFO packet sent to control port 9121.
CVE-2017-15665 1 Flexense 1 Diskboss 2018-02-01 5.0 MEDIUM 7.5 HIGH
In Flexense DiskBoss Enterprise 8.5.12, the Control Protocol suffers from a denial of service vulnerability. The attack vector is a crafted SERVER_GET_INFO packet sent to control port 8094.
CVE-2017-17088 1 Flexense 1 Syncbreeze 2018-01-04 5.0 MEDIUM 7.5 HIGH
The Enterprise version of SyncBreeze 10.2.12 and earlier is affected by a Remote Denial of Service vulnerability. The web server does not check bounds when reading server requests in the Host header on making a connection, resulting in a classic Buffer Overflow that causes a Denial of Service.
CVE-2017-17099 1 Flexense 1 Syncbreeze 2017-12-20 7.2 HIGH 7.8 HIGH
There exists an unauthenticated SEH based Buffer Overflow vulnerability in the HTTP server of Flexense SyncBreeze Enterprise v10.1.16. When sending a GET request with an excessive length, it is possible for a malicious user to overwrite the SEH record and execute a payload that would run under the Windows SYSTEM account.