Filtered by vendor Eq-3
Subscribe
Search
Total
15 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2019-14423 | 1 Eq-3 | 3 Ccu2, Ccu2 Firmware, Cux-daemon | 2021-07-21 | 9.0 HIGH | 8.8 HIGH |
| A Remote Code Execution (RCE) issue in the addon CUx-Daemon 1.11a of the eQ-3 Homematic CCU-Firmware 2.35.16 until 2.45.6 allows remote authenticated attackers to execute system commands as root remotely via a simple HTTP request. | |||||
| CVE-2019-9727 | 1 Eq-3 | 2 Ccu3, Ccu3 Firmware | 2020-08-24 | 5.0 MEDIUM | 7.5 HIGH |
| Unauthenticated password hash disclosure in the User.getUserPWD method in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to retrieve the GUI password hashes of GUI users. This vulnerability can be exploited by unauthenticated attackers with access to the web interface. | |||||
| CVE-2019-14475 | 1 Eq-3 | 4 Ccu2, Ccu2 Firmware, Ccu3 and 1 more | 2020-08-24 | 5.0 MEDIUM | 7.5 HIGH |
| eQ-3 Homematic CCU2 2.47.15 and prior and CCU3 3.47.15 and prior use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID from CVE-2019-9583, resulting in the ability to read the service messages, clear the system protocol, create a new user in the system, or modify/delete internal programs. | |||||
| CVE-2019-14473 | 1 Eq-3 | 4 Ccu2, Ccu2 Firmware, Ccu3 and 1 more | 2020-08-24 | 6.5 MEDIUM | 8.8 HIGH |
| eQ-3 Homematic CCU2 and CCU3 use session IDs for authentication but lack authorization checks. Consequently, a valid guest level or user level account can create a new admin level account, read the service messages, clear the system protocol or modify/delete internal programs, etc. pp. | |||||
| CVE-2019-14984 | 1 Eq-3 | 4 Homematic Ccu2, Homematic Ccu2 Firmware, Homematic Ccu3 and 1 more | 2020-08-24 | 6.8 MEDIUM | 8.1 HIGH |
| eQ-3 Homematic CCU2 and CCU3 with the XML-API through 1.2.0 AddOn installed allow Remote Code Execution by unauthenticated attackers with access to the web interface, because the undocumented addons/xmlapi/exec.cgi script uses CMD_EXEC to execute TCL code from a POST request. | |||||
| CVE-2019-14986 | 1 Eq-3 | 4 Homematic Ccu2, Homematic Ccu2 Firmware, Homematic Ccu3 and 1 more | 2020-08-24 | 9.3 HIGH | 8.1 HIGH |
| eQ-3 Homematic CCU2 and CCU3 with the CUxD AddOn before 2.3.0 installed allow administrative operations by unauthenticated attackers with access to the web interface, because features such as File-Browser and Shell Command (as well as "Set root password") are exposed. | |||||
| CVE-2019-15850 | 1 Eq-3 | 2 Homematic Ccu3, Homematic Ccu3 Firmware | 2020-08-24 | 9.0 HIGH | 8.8 HIGH |
| eQ-3 HomeMatic CCU3 firmware version 3.41.11 allows Remote Code Execution in the ReGa.runScript method. An authenticated attacker can easily execute code and compromise the system. | |||||
| CVE-2019-9582 | 1 Eq-3 | 2 Homematic Ccu2, Homematic Ccu2 Firmware | 2020-08-24 | 7.8 HIGH | 7.5 HIGH |
| eQ-3 Homematic CCU2 outdated base software packages allows Denial of Service. CCU2 affected versions: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. | |||||
| CVE-2019-9583 | 1 Eq-3 | 4 Homematic Ccu2, Homematic Ccu2 Firmware, Homematic Ccu3 and 1 more | 2020-04-10 | 6.4 MEDIUM | 8.2 HIGH |
| eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15. | |||||
| CVE-2019-15849 | 1 Eq-3 | 2 Homematic Ccu3, Homematic Ccu3 Firmware | 2019-10-22 | 4.9 MEDIUM | 7.3 HIGH |
| eQ-3 HomeMatic CCU3 firmware 3.41.11 allows session fixation. An attacker can create session IDs and send them to the victim. After the victim logs in to the session, the attacker can use that session. The attacker could create SSH logins after a valid session and easily compromise the system. | |||||
| CVE-2018-7298 | 1 Eq-3 | 2 Homematic Central Control Unit Ccu2, Homematic Central Control Unit Ccu2 Firmware | 2019-10-03 | 9.3 HIGH | 8.1 HIGH |
| In /usr/local/etc/config/addons/mh/loopupd.sh on eQ-3 AG HomeMatic CCU2 2.29.22 devices, software update packages are downloaded via the HTTP protocol, which does not provide any cryptographic protection of the downloaded contents. An attacker with a privileged network position (which could be obtained via DNS spoofing of www.meine-homematic.de or other approaches) can exploit this issue in order to provide arbitrary malicious firmware updates to the CCU2. This can result in a full system compromise. | |||||
| CVE-2018-7299 | 1 Eq-3 | 2 Homematic Central Control Unit Ccu2, Homematic Central Control Unit Ccu2 Firmware | 2019-10-03 | 5.2 MEDIUM | 8.0 HIGH |
| Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device. | |||||
| CVE-2019-14474 | 1 Eq-3 | 2 Ccu3, Ccu3 Firmware | 2019-08-16 | 5.0 MEDIUM | 7.5 HIGH |
| eQ-3 Homematic CCU3 3.47.15 and prior has Improper Input Validation in function 'Call()' of ReGa core logic process, resulting in the ability to start a Denial of Service. Due to Improper Authorization an attacker can obtain a session ID from CVE-2019-9583 or a valid guest/user/admin account can start this attack too. | |||||
| CVE-2019-10120 | 1 Eq-3 | 4 Ccu2, Ccu2 Firmware, Ccu3 and 1 more | 2019-07-17 | 6.5 MEDIUM | 8.8 HIGH |
| On eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16, automatic login configuration (aka setAutoLogin) can be achieved by continuing to use a session ID after a logout, aka HMCCU-154. | |||||
| CVE-2019-9726 | 1 Eq-3 | 2 Ccu3, Ccu3 Firmware | 2019-05-14 | 5.0 MEDIUM | 7.5 HIGH |
| Directory Traversal / Arbitrary File Read in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to read arbitrary files of the device's filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface. | |||||