| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-38142 | 1 Barco | 1 Mirrorop Windows Sender | 2022-07-12 | 7.2 HIGH | 8.8 HIGH |
| Barco MirrorOp Windows Sender before 2.5.3.65 uses cleartext HTTP and thus allows rogue software upgrades. An attacker on the local network can achieve remote code execution on any computer that tries to update Windows Sender due to the fact that the upgrade mechanism is not secured (is not protected with TLS). | |||||
| CVE-2020-28331 | 1 Barco | 2 Wepresent Wipg-1600w, Wepresent Wipg-1600w Firmware | 2022-07-12 | 5.0 MEDIUM | 7.5 HIGH |
| Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots. | |||||
| CVE-2022-26975 | 1 Barco | 1 Control Room Management Suite | 2022-06-09 | 5.0 MEDIUM | 7.5 HIGH |
| Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication. | |||||
| CVE-2021-35482 | 1 Barco | 1 Mirrorop Windows Sender | 2021-07-30 | 4.6 MEDIUM | 7.8 HIGH |
| An issue was discovered in Barco MirrorOp Windows Sender before 2.5.4.70. An attacker in the local network is able to achieve Remote Code Execution (with user privileges of the local user) on any device that tries to connect to a WePresent presentation system. | |||||
| CVE-2019-18829 | 1 Barco | 2 Clickshare Button R9861500d01, Clickshare Button R9861500d01 Firmware | 2021-07-21 | 4.4 MEDIUM | 7.8 HIGH |
| Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The Barco signed 'Clickshare_For_Windows.exe' binary on the ClickShare Button (R9861500D01) loads a number of DLL files dynamically without verifying their integrity. | |||||
| CVE-2019-18832 | 1 Barco | 2 Clickshare Button R9861500d01, Clickshare Button R9861500d01 Firmware | 2021-07-21 | 6.8 MEDIUM | 8.1 HIGH |
| Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01. | |||||
| CVE-2020-17503 | 1 Barco | 5 Transform N, Transform Ndn-210 Lite, Transform Ndn-210 Pro and 2 more | 2021-01-14 | 6.5 MEDIUM | 7.2 HIGH |
| The NDN-210 has a web administration panel which is made available over https. There is a command injection issue that will allow authenticated users to the administration panel to perform authenticated remote code execution. An issue exists in split_card_cmd.php in which the http parameter "locking" is not properly handled. The NDN-210 is part of Barco TransForm N solution and this vulnerability is patched from TransForm N version 3.8 onwards. | |||||
| CVE-2020-17504 | 1 Barco | 5 Transform N, Transform Ndn-210 Lite, Transform Ndn-210 Pro and 2 more | 2021-01-14 | 6.5 MEDIUM | 7.2 HIGH |
| The NDN-210 has a web administration panel which is made available over https. There is a command injection issue that will allow authenticated users to the administration panel to perform authenticated remote code execution. An issue exists in ngpsystemcmd.php in which the http parameters "x_modules" and "y_modules" are not properly handled. The NDN-210 is part of Barco TransForm N solution and this vulnerability is patched from TransForm N version 3.8 onwards. | |||||
| CVE-2020-17502 | 1 Barco | 5 Transform N, Transform Ndn-210 Lite, Transform Ndn-210 Pro and 2 more | 2021-01-13 | 6.5 MEDIUM | 7.2 HIGH |
| Barco TransForm N before 3.8 allows Command Injection (issue 2 of 4). The NDN-210 has a web administration panel which is made available over https. There is a command injection issue that will allow authenticated users of the administration panel to perform authenticated remote code execution. An issue exists in split_card_cmd.php in which the http parameters xmodules, ymodules and savelocking are not properly handled. The NDN-210 is part of Barco TransForm N solution and includes the patch from TransForm N version 3.8 onwards. | |||||
| CVE-2019-18825 | 1 Barco | 4 Clickshare Cs-100 Huddle, Clickshare Cs-100 Huddle Firmware, Clickshare Cse-200 and 1 more | 2019-12-26 | 5.0 MEDIUM | 7.5 HIGH |
| Barco ClickShare Huddle CS-100 devices before 1.9.0 and CSE-200 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Base Unit implements encryption at rest using encryption keys which are shared across all ClickShare Base Units of models CS-100 & CSE-200. | |||||
| CVE-2017-9377 | 1 Barco | 4 Clickshare Csc-1, Clickshare Csc-1 Firmware, Clickshare Csm-1 and 1 more | 2019-10-03 | 9.0 HIGH | 8.8 HIGH |
| A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device. | |||||
| CVE-2016-3151 | 1 Barco | 6 Clickshare Csc-1, Clickshare Csc-1 Firmware, Clickshare Cse-200 and 3 more | 2018-10-09 | 5.0 MEDIUM | 7.5 HIGH |
| Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors. | |||||
| CVE-2018-10943 | 1 Barco | 4 Clickshare Cs-100, Clickshare Cs-100 Firmware, Clickshare Cse-200 and 1 more | 2018-09-11 | 7.8 HIGH | 7.5 HIGH |
| An issue was discovered on Barco ClickShare CSE-200 and CS-100 Base Units with firmware before 1.6.0.3. Sending an arbitrary unexpected string to TCP port 7100 respecting a certain frequency timing disconnects all clients and results in a crash of the Unit. | |||||