Search
Total
3 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-10955 | 1 Emc | 1 Data Protection Advisor | 2019-10-09 | 9.0 HIGH | 8.8 HIGH |
| ** DISPUTED ** This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of EMC Data Protection Advisor 6.3.0. Authentication is required to exploit this vulnerability. The specific flaw exists within the EMC DPA Application service, which listens on TCP port 9002 by default. When parsing the preScript parameter, the process does not properly validate a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute arbitrary code under the context of SYSTEM. Was ZDI-CAN-4697. NOTE: Dell EMC disputes that this is a vulnerability. | |||||
| CVE-2018-1206 | 1 Emc | 1 Data Protection Advisor | 2018-04-13 | 7.2 HIGH | 7.8 HIGH |
| Dell EMC Data Protection Advisor versions prior to 6.3 Patch 159 and Dell EMC Data Protection Advisor versions prior to 6.4 Patch 110 contain a hardcoded database account with administrative privileges. The affected account is "apollosuperuser." An attacker with local access to the server where DPA Datastore Service is installed and knowledge of the password may potentially gain unauthorized access to the database. Note: The Datastore Service database cannot be accessed remotely using this account. | |||||
| CVE-2017-8002 | 1 Emc | 1 Data Protection Advisor | 2017-07-17 | 6.5 MEDIUM | 8.8 HIGH |
| EMC Data Protection Advisor prior to 6.4 contains multiple blind SQL injection vulnerabilities. A remote authenticated attacker may potentially exploit these vulnerabilities to gain information about the application by causing execution of arbitrary SQL commands. | |||||