Vulnerabilities (CVE)

Filtered by vendor Codesys Subscribe
Filtered by product Control For Beaglebone Sl
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-6357 1 Codesys 11 Control For Beaglebone Sl, Control For Empc-a\/imx6, Control For Iot2000 Sl and 8 more 2023-12-11 N/A 8.8 HIGH
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
CVE-2022-4224 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2023-08-09 N/A 8.8 HIGH
In multiple products of CODESYS v3 in multiple versions a remote low privileged userĀ could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
CVE-2022-4046 1 Codesys 14 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 11 more 2023-08-08 N/A 8.8 HIGH
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
CVE-2022-22515 1 Codesys 18 Control For Beaglebone Sl, Control For Beckhoff Cx9020, Control For Empc-a\/imx6 Sl and 15 more 2022-05-12 4.9 MEDIUM 8.1 HIGH
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
CVE-2022-22514 1 Codesys 20 Control For Beaglebone Sl, Control For Beckhoff Cx9020, Control For Empc-a\/imx6 Sl and 17 more 2022-05-10 4.9 MEDIUM 7.1 HIGH
An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash.
CVE-2022-22519 1 Codesys 18 Control For Beaglebone Sl, Control For Beckhoff Cx9020, Control For Empc-a\/imx6 Sl and 15 more 2022-05-10 5.0 MEDIUM 7.5 HIGH
A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system.
CVE-2021-29241 1 Codesys 11 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 8 more 2021-12-16 5.0 MEDIUM 7.5 HIGH
CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).
CVE-2021-29242 1 Codesys 22 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 19 more 2021-09-14 7.5 HIGH 7.3 HIGH
CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
CVE-2019-9013 1 Codesys 12 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 9 more 2020-08-24 5.8 MEDIUM 8.8 HIGH
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.
CVE-2019-9012 1 Codesys 10 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 7 more 2020-08-24 7.8 HIGH 7.5 HIGH
An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.
CVE-2018-20026 1 Codesys 18 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 15 more 2020-08-24 5.0 MEDIUM 7.5 HIGH
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
CVE-2018-20025 1 Codesys 15 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 12 more 2019-04-02 5.0 MEDIUM 7.5 HIGH
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.